《ASTM E415-2014 red 0161 Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry《采用火花原子发射光谱法分析碳素和低合金钢的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E415-2014 red 0161 Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry《采用火花原子发射光谱法分析碳素和低合金钢的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E415 08E415 14Standard Test Method forAtomic Emission Vacuum Spectrometric Analysis of Carbonand Low-Alloy Steel by Spark Atomic EmissionSpectrometry1This standard is issued under the fixed designation E415; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the simultaneous determination of 20 alloyin
3、g and residual elements in carbon and low-alloy steelsin the concentration by spark atomic emission vacuum spectrometry in the mass fraction ranges shown (Note 1).Concentration Range, %Composition Range, %Element Applicable Range,Mass Fraction %AQuantitative Range,Mass Fraction %BAluminum 0 to 0.075
4、 0.02 to 0.075Arsenic 0 to 0.1 0.05 to 0.1Boron 0 to 0.007 0.002 to 0.007Calcium 0 to 0.003 0.001 to 0.003Carbon 0 to 1.1 0.08 to 1.1Chromium 0 to 2.25 0.02 to 2.25Cobalt 0 to 0.18 0.008 to 0.18Copper 0 to 0.5 0.04 to 0.5Manganese 0 to 2.0 0.10 to 2.0Molybdenum 0 to 0.6 0.03 to 0.6Nickel 0 to 5.0 0.
5、02 to 5.0Niobium 0 to 0.085 0.02 to 0.085Nitrogen 0 to 0.015 0.004 to 0.015Phosphorous 0 to 0.085 0.02 to 0.085Silicon 0 to 1.15 0.07 to 1.15Sulfur 0 to 0.055 0.01 to 0.055Tin 0 to 0.045 0.01 to 0.045Titanium 0 to 0.2 0.004 to 0.2Vanadium 0 to 0.3 0.004 to 0.3Zirconium 0 to 0.05 0.02 to 0.05A Applic
6、able range in accordance with Guide E1763 for results reported in accordance with Practice E1950.B Quantitative range in accordance with Practice E1601.NOTE 1The concentration mass fraction ranges of the elements listed have been established through cooperative testing2 of reference materials.Includ
7、ed, in addition to the original data of Test Method E415 71, are data from cooperative testing of a broader range of reference materials to expandthe element concentration mass fraction ranges.1.2 This test method covers analysis of specimens having a diameter adequate to overlap and seal the bore o
8、f the spark standopening (to effect an argon seal). opening. The specimen thickness can vary significantly according to the design of thespectrometer stand, but a thickness between 10 mm and 38 mm has been found to be most practical.1.3 This test method covers the routine control analysis in iron an
9、d steelmaking operations and the analysis of processedmaterial. It is designed for chill-cast, rolled, and forged specimens. Better performance is expected when reference materials andspecimens are of similar metallurgical condition and composition. However, it is not required for all applications o
10、f this standard.1 This test method is under the jurisdiction of ASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials and is the direct responsibility ofSubcommittee E01.01 on Iron, Steel, and Ferroalloys.Current edition approved June 1, 2008March 1, 2014. Published July
11、 2008April 2014. Originally approved in 1971. Last previous edition approved in 20052008 asE415 99a (2005).E415 08. DOI: 10.1520/E0415-08.2 Supporting data have been filed at ASTM International Headquarters and may be obtained by requesting Research Report: RR:E2-1004.This document is not an ASTM st
12、andard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all ca
13、ses only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.4 This standard does not purport to address all of the safety concerns, if an
14、y, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E135 Terminology Relating to Analytical Chemistry for
15、 Metals, Ores, and Related MaterialsE158 Practice for Fundamental Calculations to Convert Intensities into Concentrations in Optical Emission SpectrochemicalAnalysis (Withdrawn 2004)4E305 Practice for Establishing and Controlling Atomic Emission Spectrochemical Analytical CurvesE350 Test Methods for
16、 Chemical Analysis of Carbon Steel, Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, and WroughtIronE406 Practice for Using Controlled Atmospheres in Spectrochemical AnalysisE1019 Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys b
17、yVarious Combustion and Fusion TechniquesE1329 Practice for Verification and Use of Control Charts in Spectrochemical AnalysisE1601 Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical MethodE1763 Guide for Interpretation and Use of Results from Interlaborato
18、ry Testing of Chemical Analysis MethodsE1806 Practice for Sampling Steel and Iron for Determination of Chemical CompositionE1950 Practice for Reporting Results from Methods of Chemical Analysis2.2 Other ASTM DocumentsASTM MNL 7 Manual on Presentation of Data and Control Chart Analysis43. Terminology
19、3.1 For definitions of terms used in this test method, refer to Terminology E135.4. Summary of Test Method4.1 A capacitor discharge is produced between the flat, ground surface of the disk specimen and a conically shaped electrode.The discharge is terminated at a predetermined intensity time integra
20、l of a selected iron line, or at a predetermined time, and therelative radiant energies of the analytical lines are recorded. The most sensitive lines of arsenic, boron, carbon, nitrogen,phosphorus, sulfur, and tin lie in the vacuum ultraviolet region. The absorption of the radiation by air in this
21、region is overcomeby evacuating the spectrometer and flushing the spark chamber with argon.5. Significance and Use5.1 This test method for the spectrometric analysis of metals and alloys is primarily intended to test such materials forcompliance with compositional specifications. It is assumed that
22、all who use this test method will be analysts capable of performingcommon laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.6. Apparatus6.1 Sampling Devices:6.1.1 Refer to Practice E1806 for devices and practices to sample liqui
23、d and solid iron and steel.6.2 Excitation Source, capable of providing electrical parameters to spark a sample. See 11.1 for details.6.3 Spark Chamber, automatically flushed with argon. The spark chamber shall be mounted directly on the spectrometer andshall be provided with a spark stand to hold a
24、flat specimen and a lower counter electrode of rod form.NOTE 2Follow the manufacturers recommendations for cleaning the excitation chamber (during continuous operation, this typically should be doneevery 24 h). Follow the manufacturers recommendations for cleaning the entrance lens or window (verifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4152014RED0161STANDARDTESTMETHODFORANALYSISOFCARBONANDLOWALLOYSTEELBYSPARKATOMICEMISSIONSPECTROMETRY

链接地址:http://www.mydoc123.com/p-532725.html