《ASTM E3147-2018 Standard Practice for Evaluating DICONDE Interoperability of Nondestructive Testing and Inspection Systems《无损检测和检验系统的DICONDE互操作性评定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E3147-2018 Standard Practice for Evaluating DICONDE Interoperability of Nondestructive Testing and Inspection Systems《无损检测和检验系统的DICONDE互操作性评定的标准实施规程》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3147 18Standard Practice forEvaluating DICONDE Interoperability of NondestructiveTesting and Inspection Systems1This standard is issued under the fixed designation E3147; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes procedures for evaluating DI-CONDE compliance of radiographic, ultrasonic and ed
3、dycurrent examination instruments and systems.1.2 This practice establishes no performance limits forexamination systems; if such acceptance criteria are required,these must be specified by the using parties. Where acceptancecriteria are implied herein they are for example only and aresubject to mor
4、e or less restrictive limits imposed by customersand end users controlling documents.1.3 The specific parameters to be evaluated, conditions andfrequency of test, and report data required, must also bedetermined by the user.1.4 This practice may be used for the evaluation of acomplete examination sy
5、stem, including search unit,instrument, interconnections, scanner fixtures and connectedalarm and auxiliary devices, primarily in cases where such asystem is used repetitively without change or substitution. Thispractice is not intended to be used as a substitute for calibrationor standardization of
6、 an instrument or system to inspect anygiven material.1.5 Alternate procedures, such as examples described in thispractice, or others, may only be used with customer approval.1.6 It is expected that the customer sets the requirements forthe level to which this practice be conformed, including thereq
7、uirements for which functionality and DICONDE interop-erability be incorporated for testing.1.7 Two customer types are targeted for usage: a high-levelpurchaser wishing to quickly assess results and a low-levelsystems developer wishing to understand the details about theextent of the results, as dis
8、cussed in Section 5.1.8 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standa
9、rd to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.10 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on
10、 Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:E1316 Terminology for Nondestructive ExaminationsE2339 Practice for Digital Imaging and C
11、ommunication inNondestructive Evaluation (DICONDE)E2663 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for UltrasonicTest MethodsE2699 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for Digital Ra-diographic (DR) Test Method
12、sE2738 Practice for Digital Imaging and CommunicationNondestructive Evaluation (DICONDE) for ComputedRadiography (CR) Test MethodsE2767 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE) for X-ray Com-puted Tomography (CT) Test MethodsE2934 Practice for Digital Imag
13、ing and Communication inNondestructive Evaluation (DICONDE) for Eddy Current(EC) Test Methods2.2 DICOM StandardsNEMA Standards Publication PS3, Version 3 Digital Imag-ing and Communications in Medicine (DICOM)ACR-NEMA 300-1998 Digital Imaging and Communica-tions in Medicine3. Terminology3.1 Refer to
14、 Terminology E1316 for definitions of terms inthis practice.3.2 Definitions:1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalImaging and Communication in Nondestructive Evaluation (DICONDE).Cur
15、rent edition approved Feb. 1, 2018. Published February 2018. DOI: 10.1520/E314718.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on sta
16、ndardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2.1 application entity (AE)a local or remote DICOM(DICONDE) service.3.2.2 AE titlethe
17、 name of the application entity, forexample, the name of the computer running the local or remoteservice, or other user-defined name of the application entity.3.2.3 connectivitythe ability to establish a connectionbetween two or more systems and exchange messages.3.2.4 DICONDE interconnectivitythe l
18、evel to which twoapplication entities can exchange messages using the DI-CONDE protocol.3.2.5 DICONDE interoperabilityability for two applica-tion entities to exchange composite information objects orinformation about normalized information objects and for eachentity to interpret, view, and present
19、that info in the same way.3.2.6 DICONDE validationthe assurance that the NDEsystem meets the needs of the purchaser and other identifiedstakeholders. It often involves acceptance with external enti-ties.3.2.7 DICONDE verificationthe evaluation of whether theNDE system conforms to the DICONDE standar
20、d. It is oftenan internal process.3.2.8 PS3NEMA DICOM standard publication.3.2.9 SCPa Service Class Provider (SCP) is a device thatacts as a server and “provides” a DICONDE service. SCP typesmost commonly include the storage type (C-STORE orC-MOVE) to accept data that is transmitted from anotherdevi
21、ce and the find type (C-FIND) to respond to searches(queries) for data and fulfill transmission requests. A devicemay serve as both SCP and SCU. Refer to PS3.4 for moreinformation. See Section 5 for diagram.3.2.10 SCUa Service Class User (SCU) is a device thatinitiates DICONDE requests from an SCP.
22、SCU types mostcommonly include the storage type (C-STORE or C-MOVE) toallow sending of data to another device for storage and the findtype (C-FIND) to enable searching and retrieval of stored data.A device may serve as both SCU and SCP. Refer to PS3.4 formore information. See Section 5 for diagram.3
23、.2.11 validation systemthe real-world application entitythat interconnectivity and interoperability is tested against.3.2.12 verification systemthe system that a vendor usesinternally to verify conformance to the DICONDE standard.An example is DVTk: See Appendix X1 and Appendix X2.4. Summary of Prac
24、tice4.1 This practice is intended for use by NDE systemmanufacturers and NDE system purchasers, who need to assessthe technical extent of a systems compliance and conformanceto the DICONDE standard. The procedure is organized in sucha way that the level to which the DICONDE standard issupported is e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME31472018STANDARDPRACTICEFOREVALUATINGDICONDEINTEROPERABILITYOFNONDESTRUCTIVETESTINGANDINSPECTIONSYSTEMS

链接地址:http://www.mydoc123.com/p-532379.html