《ASTM E2927-2016e1 Standard Test Method for Determination of Trace Elements in Soda-Lime Glass Samples Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Forensic.pdf》由会员分享,可在线阅读,更多相关《ASTM E2927-2016e1 Standard Test Method for Determination of Trace Elements in Soda-Lime Glass Samples Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Forensic.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2927 161Standard Test Method forDetermination of Trace Elements in Soda-Lime GlassSamples Using Laser Ablation Inductively Coupled PlasmaMass Spectrometry for Forensic Comparisons1This standard is issued under the fixed designation E2927; the number immediately following the designatio
2、n indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections were made to 11.1 in
3、December 2017.INTRODUCTIONOne objective of a forensic glass examination is to compare glass samples to determine if they maybe discriminated using their physical, optical or chemical properties (for example, color, refractiveindex (RI), density, elemental composition). If the samples are distinguish
4、able in any of theseobserved and measured properties, it may be concluded that they did not originate from the samesource of broken glass. If the samples are indistinguishable in all of these observed and measuredproperties, the possibility that they originated from the same source of glass may not
5、be eliminated.The use of an elemental analysis method such as laser ablation inductively coupled plasma massspectrometry yields high discrimination among sources of glass.1. Scope1.1 This test method covers a procedure for the quantitativeelemental analysis of the following seventeen elements:lithiu
6、m (Li), magnesium (Mg), aluminum (Al), potassium (K),calcium (Ca), iron (Fe), titanium (Ti), manganese (Mn),rubidium (Rb), strontium (Sr), zirconium (Zr), barium (Ba),lanthanum (La), cerium (Ce), neodymium (Nd), hafnium (Hf)and lead (Pb) through the use of Laser Ablation InductivelyCoupled Plasma Ma
7、ss Spectrometry (LA-ICP-MS) for theforensic comparison of glass fragments. The potential of theseelements to provide the best discrimination among differentsources of soda-lime glasses has been published elsewhere(1-5).2Silicon (Si) is also monitored for use as a normalizationstandard. Additional el
8、ements may be added as needed, forexample, tin (Sn) can be used to monitor the orientation of floatglass fragments.1.2 The method only consumes approximately 0.4 to 2 g ofglass per replicate and is suitable for the analysis of fullthickness samples as well as irregularly shaped fragments assmall as
9、0.1 mm by 0.4 mm in dimension. The concentrationsof the elements listed above range from the low parts permillion (gg-1) to percent (%) levels in soda-lime-silicate glass,the most common type encountered in forensic cases. Thisstandard method may be applied for the quantitative analysis ofother glas
10、s types; however, some modifications in the referencestandard glasses and the element menu may be required.1.3 This standard does not replace knowledge, skill, ability,experience, education or training and should be used inconjunction with professional judgment.1.4 The values stated in SI units are
11、to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices a
12、nd determine the applica-bility of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom
13、-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.1This test method is under the jurisdiction ofASTM Committee E30 on ForensicSciences and is the direct responsibility of Subcommittee E30.01 on Criminalistics.Current edition approved Dec. 1, 2016. Publishe
14、d April 2017. Originallyapproved in 2013. Last previous edition approved in 2013 as E2927 13. DOI:10.1520/E2927-16E01.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
15、19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Te
16、chnical Barriers to Trade (TBT) Committee.12. Referenced Documents2.1 ASTM Standards:3E2330 Test Method for Determination of Concentrations ofElements in Glass Samples Using Inductively CoupledPlasma Mass Spectrometry (ICP-MS) for Forensic Com-parisonsE177 Practice for Use of the Terms Precision and
17、 Bias inASTM Test MethodsC162 Terminology of Glass and Glass Products3. Terminology3.1 Definitions:3.1.1 calibration standard, nused to determine the quan-titative analysis for the analyte elements of interest in the glassmatrix. The calibration standard(s) shall have a known elemen-tal composition
18、including a known uncertainty for the reportedanalytes.3.1.2 glass, nan inorganic product of fusion that has beencooled to a rigid condition without crystallization. C1623.1.3 normalization standard, nan element that is presentin the glass matrix at elevated and relatively homogeneousconcentration t
19、hat may be used to normalize the laser ablationsignal to compensate for any variation on the ablated mass orinstrumental drift.4. Summary of Test Method4.1 The glass fragments usually do not require samplepreparation prior to the LA-ICP-MS analysis. However, theymay be washed with solvents or pre-ab
20、lated if necessary.4.2 The glass fragment is placed inside an ablation chamberand a laser beam is focused on the surface of the sample. Whenthe ablation is started, the interaction between the pulsed laserand the sample surface produces a cloud of very smallparticles, which are transported from the
21、ablation cell by acarrier gas into the ICP-MS for analysis.4.3 An ICP-MS is used to quantify the elements of interest.4.4 Quantitative analysis is accomplished using well-characterized glass standards whose major elemental compo-sition is similar to the material to be analyzed.4.5 A comparison betwe
22、en the reported elemental composi-tions of the known and recovered glass fragments may result ina decision on whether the samples are distinguishable byelemental composition or indistinguishable by elemental com-position.5. Significance and Use5.1 This test method is useful for the determination ofe
23、lemental concentrations in the microgram per gram (gg-1)topercent (%) levels in soda-lime glass samples. A standard testmethod may aid in the interchange of data between laboratoriesand in the creation and use of glass databases.5.2 The determination of elemental concentrations in glassprovides high
24、 discriminating value in the forensic comparisonof glass fragments.5.3 This test method produces minimal destruction of thesample. Microscopic craters of 50 to 100 m in diameter by 80to 150-m deep are left in the glass fragment after analysis. Themass removed per replicate is approximately 0.4 to 3.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29272016E1STANDARDTESTMETHODFORDETERMINATIONOFTRACEELEMENTSINSODALIMEGLASSSAMPLESUSINGLASERABLATIONINDUCTIVELYCOUPLEDPLASMAMASSSPECTROMETRYFORFORENSICPDF

链接地址:http://www.mydoc123.com/p-532120.html