1、Designation: E2748 11An American National StandardStandard Guide forFire-Resistance Experiments1This standard is issued under the fixed designation E2748; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis guide provides a means for ensuring comparability of findings among different researchersconducting fire-resistance experiments e
3、mploying innovative and creative variations to standard testmethods. This guide is intended to bring uniformity and consistency to tests and reports coveringfire-resistance research that is generally conducted as a variation of Test Methods E119. Its provisionsare voluntary and users are free to pic
4、k and choose from the provisions herein provided. Theoverriding goal is to make it possible to begin to provide data that ultimately can be used in fire safetyengineering and fire-resistance modeling as those fields evolve. When the purpose of the research isto study the effect of changing specific
5、individual variables on the outcome of Test Methods E119fire-resistance tests, sound research practices dictate that only one variable should be changed at atime.1. Scope1.1 This guide covers the conduct of fire-resistance testsusing conditions different than those addressed in Test MethodsE119. Thi
6、s guide also addresses the reporting of data derivedfrom those tests.1.2 This guide does not provide or generate fire-resistanceratings suitable for determining compliance with code orregulatory requirements comparable to those resulting fromtests conducted in accordance with Test Methods E119.1.3 T
7、he values stated in SI units are to be regarded asstandard. The values in parentheses are for information only.1.4 This guide is used to measure and describe the responseof materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate allfactors
8、required for fire hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pri
9、ate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E119 Test Methods for Fire Tests of Building Constructionand MaterialsE176 Terminology of Fire StandardsE603 Guide for Room Fire ExperimentsE1529 Test Me
10、thods for Determining Effects of LargeHydrocarbon Pool Fires on Structural Members and As-semblies2.2 Other Standards:ISO 834-1 Fire Resistance Tests Elements of BuildingConstruction Part 1: General Requirements3NFPA 251 Standard Methods of Tests of Fire Resistance ofBuilding Construction and Materi
11、als43. Terminology3.1 Definitions: For definitions of terms used in this guide,refer to Terminology E176.1This guide is under the jurisdiction ofASTM Committee E05 on Fire Standardsand is the direct responsibility of Subcommittee E05.11 on Fire Resistance.Current edition approved May 15, 2011. Publi
12、shed June 2011. Originallyapproved in 2010 as E274810. DOI: 10.1520/E2748-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page ont
13、he ASTM website.3Available from International Organization for Standardization, P.O. Box 56,CH-1211, Geneva 20, Switzerland.4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.1Copyright ASTM International, 100 Barr Harbor Drive,
14、 PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 The methods and procedures set forth in this guide relateto the conduct and reporting of fire-resistance tests obtainedfrom particular fire-resistance tested specimens tested usingconditions different than those
15、 addressed by Test MethodsE119.4.2 Data derived from fire tests conducted and reportedunder this guide are useful for general fire research and aspotential input data for use in fire models.4.3 It is necessary that users of this guide have knowledgeand understanding of the provisions of Test Methods
16、 E119,including those pertaining to conditions of acceptance in orderto understand how the alternative test conditions relate to thosespecified in Test Methods E119.4.4 Users of this guide should be aware that tests conductedusing exposure conditions different than those specified in TestMethods E11
17、9 do not provide or generate fire resistance ratingssuitable for determining compliance with code or regulatoryrequirements.4.4.1 In Test Methods E119, standard test specimens aresubjected to specific exposure conditions. Substitution ofdifferent exposure conditions can change the measured fire-test
18、-response characteristics of a test specimen. Therefore, thedata are valid for only the alternative exposure conditions used.5. General Principles5.1 Except as specifically modified herein, fire-resistancetests should be conducted using the test furnaces, exposureconditions, test specimens, instrume
19、ntation, and acceptancecriteria set forth in Test Methods E119.5.2 Although it is possible to vary many variables at onetime, and it may be desirable to do so when evaluating theresponse of a specimen to specific design fire conditions, it isusually desirable to vary only one parameter at a time whe
20、ncomparing results from two or more tests or when evaluatingthe effect on fire resistance of changing a specific variable.5.3 LimitationsThe test data is valid for only the speci-men and parameters used in the test.6. Alternative Time-Temperature Curves6.1 The provisions in this section are applicab
21、le to the use ofalternative time-temperature curves that are different from thetime-temperature curve specified in Test Methods E119.6.1.1 When the time-temperature curve specified in TestMethods E119 is used, it should be so stated in the report.NOTE 1There are a number of recognized time-temperatu
22、re curves inuse in fire-resistance test standards around the world.6.2 When a recognized or published time-temperature curveis used, the reference in which the curve is described should becited and the time-temperature curve should be reported.6.3 Fire safety engineering and computer modeling aremet
23、hods whereby non-standard time-temperature curves can bederived to represent specific design conditions.6.3.1 When these design fires are used as the basis of atime-temperature curve, a table or equation representing thecurve should be reported.7. Alternative Pressure Differentials7.1 The provisions
24、 in this section are applicable to the use ofspecific furnace pressure differentials.NOTE 2There are a number of recognized or published furnacepressure differentials in use in fire test standards around the world.7.2 When a recognized or published furnace pressure dif-ferential is used, the referen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27482011STANDARDGUIDEFORFIRERESISTANCEEXPERIMENTS 耐火 实验 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-531811.html