ASTM E2342 E2342M-2010(2015)e1 Standard Test Method for Durability Testing of Duct Sealants《管道密封剂耐久检验的标准试验方法》.pdf
《ASTM E2342 E2342M-2010(2015)e1 Standard Test Method for Durability Testing of Duct Sealants《管道密封剂耐久检验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2342 E2342M-2010(2015)e1 Standard Test Method for Durability Testing of Duct Sealants《管道密封剂耐久检验的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2342/E2342M 10 (Reapproved 2015)1Standard Test Method forDurability Testing of Duct Sealants1This standard is issued under the fixed designation E2342/E2342M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits statement was inserted in 1.4 and units information was corrected editorially in February 2015.INTRODUCTIONDuct leaka
3、ge has been identified as a major source of energy loss in residential buildings. Most ductleakage occurs at the connections to registers, plenums, or branches in the duct system. At each ofthese connections a method of sealing the duct system is required. Typical sealing methods includetapes or mas
4、tics applied around the joints in the system. Field examinations of duct systems havetypically shown that these seals tend to fail over extended periods of time.The proposed method evaluates the durability of duct sealants by blowing heated air into testsections, combined with a pressure difference
5、between the test sections and their surroundings. Thetemperatures and pressures were chosen to expose the test sections to typical conditions that are foundin residential duct systems. The duct leakage site geometry represents a leakage site commonly foundin duct systems. The test sections are const
6、ructed from standard duct fittings.1. Scope1.1 This test method describes an accelerated aging test forevaluating the durability of duct sealants by exposure totemperatures and static pressures characteristic of residentialduct systems.1.2 This test method is intended to produce a relativemeasure of
7、 the durability of duct sealants. This standard doesnot measure durability under specific conditions of weather andbuilding operation that might be experienced by an individualbuilding and duct system. Instead it evaluates the sealantmethod under fixed conditions that do not include the manifoldeffe
8、cts of installation practice.1.3 This test method only addresses sealants not mechanicalstrength of the connections.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsyst
9、em shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
10、 appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements see Section 7.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building Constructions3. Terminology3.1 Terminology E631 defines much of the t
11、erminologyused in this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 air-leakage ratethe volume of air movement perunit time across the duct wall.3.2.2 duct sealanta method or material, or both, forsealing leaks in forced air thermal distribution duct systems.3.2.3 durabilityt
12、he capability of maintaining the service-ability of a product, component, or assembly over a specifiedtime.4. Summary of Test Method4.1 To evaluate sealant durability this test method uses astandardized joint configuration with controlled temperature1This test method is under the jurisdiction of AST
13、M Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.41on Air Leakage and Ventilation Performance.Current edition approved Jan. 1, 2015. Published February 2015. Originallyapproved in 2003. Last previous edition approved in 2010 as E2342 10. DOI:10.1520/E23
14、42_E2342M-10R15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Har
15、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1and pressure differences. These temperatures and pressures arechosen to represent conditions found in residential duct sys-tems. The test apparatus applies temperature and pressureconditions and measures how well the sealant per
16、forms overtime.5. Significance and Use5.1 Residential duct systems are often field designed andassembled. There are many joints, often of dissimilar materialsthat require both mechanical connection and air sealing.Without this sealing, duct systems would be extremely leakyand hence inefficient. Whil
17、e some duct sealants are rated ontheir properties at the time of manufacture or during storage,none of these ratings adequately addresses the in-servicelifetime. This test method has been developed to address thisdurability issue.5.2 This standard applies to products which list duct sealingas one of
18、 their uses. This includes duct tape (cloth, metal foil,or plastic backed), mastics, and sprayed/aerosol sealants. Itdoes not apply to caulks or plaster patches that are not intendedto be permanent duct sealing methods.5.3 The standard duct leak site is a collar to plenumconnection for round duct th
19、at is 10 to 20 cm 4 to 8 in. indiameter. This perpendicular connection was chosen becausealmost all residential duct systems have this type of connectionand in field observations of duct systems, it is often this type ofconnection that has sealant failure.6. Apparatus6.1 The following is a general d
20、escription of the requiredapparatus. Any arrangement of equipment using the sameprinciples and capable of performing the test procedure withinthe allowable tolerances is permitted.6.2 Major ComponentsThere are two major componentsrequired to perform the testing: a test section leakage measure-ment d
21、evice (Fig. 1) and a durability test apparatus (Fig. 2).6.2.1 Test Section Leakage Measuring DeviceAdevice formeasuring the leakage of individual test sections. This deviceshall consist of a fan to blow air into the test section, a flowmeasurement device for measuring the flow rate in the testsectio
22、n, a pressure measuring device for measuring the pres-sure difference between the inside and outside of the testsection, and a cap to seal the end of the test section. See Fig.2. For these test section leakage measurements, the air flowmeasuring device shall have an accuracy of 60.085 m3/h 0.05cfm o
23、r 61 % of the measured flow, whichever is greater.6.2.2 Durability Test ApparatusA device for blowing hotair through one or more test sections. This device is comprisedof the following components.6.2.2.1 Air-Moving EquipmentA fan that is capable ofmoving air through the test sections. The fan must b
24、e selectedto provide the required flow rates and pressure differences. Inaddition, the fan must be selected to be capable of operating atthe hot conditions existing in the test apparatus.FIG. 1 Schematic of Durability ApparatusE2342/E2342M 10 (2015)126.2.2.2 Pressure-Measuring DevicesManometers or p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2342E2342M20102015E1STANDARDTESTMETHODFORDURABILITYTESTINGOFDUCTSEALANTS 管道 密封剂 耐久 检验 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-530925.html