《ASTM E2140-2001 Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head《通过静水压头测试金属屋顶格间水渗透性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2140-2001 Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head《通过静水压头测试金属屋顶格间水渗透性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2140 01Standard Test Method forWater Penetration of Metal Roof Panel Systems by StaticWater Pressure Head1This standard is issued under the fixed designation E 2140; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This Laboratory test method covers the determination ofthe resistance to water penetration of exterior meta
3、l roof panelsystem sideseams, endlaps, and roof plane penetrations when aspecified static water pressure head is applied to the outsideface of the roof panel.NOTE 1This test method is intended to evaluate water-barrier (notwater-shedding) roof system joints and details. These systems are alsoreferre
4、d to as hydrostatic roof systems.1.2 This test method is limited to specimens in which thesideseams and attachments are clearly visible and in which thesource of leakage is readily observable.1.3 This test method excludes performance at roof perimeterconditions.1.4 This test method is suitable for e
5、valuating leakage atroof plane penetrations such as fasteners, curbs, pipes andexpansion joints under a static water pressure head.1.5 The proper use of this test method requires a knowledgeof the principles of water pressure.1.6 The values stated in inch-pound units are to be regardedas the standar
6、d. The SI equivalents of inch-pound units areapproximate.1.7 The text of this standard includes notes and footnotesexcluding tables and figures, which provide explanatory mate-rial. These notes and footnotes shall not be considered asrequirements of the standard.1.8 This standard does not purport to
7、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 7
8、.2. Referenced Documents2.1 ASTM Standards:E 631 Terminology of Building Construction2E 1646 Standard Test Method for Water Penetration ofExterior Metal Roof Panel Systems by Uniform Static AirPressure Difference23. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding const
9、ruction used in this method, see TerminologyE 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 composite roof systemsroof systems consisting of anexterior metal skin and other components. Factory assembledcomposite panels consist of an exterior metal skin, insulationand interior metal sk
10、in. Field assembled composite systemsconsist of exterior metal skins, underlayment and a structuralroof deck.3.2.2 panel endlapthe connection between two in-linemetal panels across the width of the panels.3.2.3 panel sideseamthe connection between two adja-cent metal panels along the length of the p
11、anels.3.2.4 specimenthe entire assembled unit submitted fortest as described in Section 8.3.2.5 water leakagepenetration of water through theplane of the innermost face of the test specimen during the testperiod.3.2.6 water pressure headthe distance from the surface ofthe water to the lowest point o
12、r cell of the metal panelspecimen, measured at the locations shown in Fig. 1.4. Summary of Test Method4.1 The test consists of sealing and fixing a test specimen toa horizontal support frame, locating vertical water dams aroundthe perimeter of the test specimen, applying a specified staticwater head
13、 to the outside face of the test specimen andobserving for water leakage on the underside of the testspecimen.5. Significance and Use5.1 This test method is a standard procedure for determiningwater leakage through metal roof panel system sideseams,endlaps, and roof plane penetrations when the roof
14、system issubjected to a specified static water pressure head.NOTE 2In applying the results of tests by this method, note that theperformance of a roof or its components or both, is in part a function of1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Building Constr
15、uctions and is the direct responsibility of Subcom-mittee E06.57 on Performance of Metal Roof Systems.Current edition approved April 10, 2001. Published May 2001.2Annual Book of ASTM Standards, Vol 04.07.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2
16、959, United States.proper installation and adjustment. In service, the performance will alsodepend on the integrity of the supporting construction, roof slope, and onthe resistance of components to deterioration by various causes: corrosiveatmosphere, aging, ice, vibration, thermal cycling, etc. It
17、is difficult tosimulate the identical complex wetting, aging and other variable condi-tions that can be encountered in service, including wind-blown pondedwater, the effects of temperature and age on sealant performance,differential pressure across the joints due to wind, snow and ice accumu-lation,
18、 densification and migration, and abrasions within the joint compo-nents which may occur during thermal cycling and other weather events.Some joint conditions are more sensitive than others to these factors.5.2 This test method will evaluate the resistance of roofpanels, sideseams, endlaps, and roof
19、 plane penetrations towater submersion. It will not evaluate panel resistance to winddriven rain.NOTE 3See E 1646 for a test which evaluates resistance to winddriven rain.5.3 This test method is not a structural adequacy test.5.4 This test method is applicable to single skin metalpanels, the exterio
20、r skin of factory assembled compositepanels, and the exterior skin of field assembled compositesystems as long as means can be provided to distinguishleakage through the exterior panel sideseams/endlaps andperimeter leakage.6. Apparatus6.1 This description of apparatus is general in nature andany ar
21、rangement of equipment capable of performing the testprocedure within the allowable tolerances is permitted.NOTE 4One such alternate test apparatus arrangement consists ofperimeter seals erected on top of the test specimen.6.2 Test Chamber(See Figs. 1 and 2). A well-sealedFIG. 1 Plan of Typical Thre
22、e-Span Test Specimen Mounted in ChamberFIG. 2 Section Through Typical Test Specimen Mounted in ChamberE2140012chamber or box with either an opening, a removable mountingpanel or one open face in which or against which the specimenis installed and sealed. The test chamber shall be maintained ina hori
23、zontal position.6.2.1 The test chamber shall be provided with a horizontalperimeter support ledge to which test specimens may beattached and sealed.6.2.2 The test specimen shall be anchored to the testchamber perimeter to adequately resist imposed test loadswithout leakage or failure.6.2.3 The test
24、chamber shall be provided with a verticalwater dam around the perimeter of the chamber. Water damshall be well sealed and of sufficient height to maintain therequired water pressure head.6.2.4 A means of viewing all areas under the roof panelspecimen shall be provided to facilitate observations for
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21402001STANDARDTESTMETHODFORWATERPENETRATIONOFMETALROOFPANELSYSTEMSBYSTATICWATERPRESSUREHEAD 通过

链接地址:http://www.mydoc123.com/p-530385.html