ASTM E2105-2000(2010) Standard Practice for General Techniques of Thermogravimetric Analysis (TGA) Coupled With Infrared Analysis (TGA IR)《(TGA IR)热重分析外加红外线分析的通用技术实施规程》.pdf
《ASTM E2105-2000(2010) Standard Practice for General Techniques of Thermogravimetric Analysis (TGA) Coupled With Infrared Analysis (TGA IR)《(TGA IR)热重分析外加红外线分析的通用技术实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2105-2000(2010) Standard Practice for General Techniques of Thermogravimetric Analysis (TGA) Coupled With Infrared Analysis (TGA IR)《(TGA IR)热重分析外加红外线分析的通用技术实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2105 00 (Reapproved 2010)Standard Practice forGeneral Techniques of Thermogravimetric Analysis (TGA)Coupled With Infrared Analysis (TGA/IR)1This standard is issued under the fixed designation E2105; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers techniques that are of general use inthe qualitative an
3、alysis of samples by thermogravimetric analy-sis (TGA) coupled with infrared (IR) spectrometric techniques.The combination of these techniques is often referred to asTGA/IR.1.2 A sample heated in a TGA furnace using a predeter-mined temperature profile typically undergoes one or moreweight losses. M
4、aterials evolved during these weight losses arethen analyzed using infrared spectroscopy to determine chemi-cal identity. The analysis may involve collecting discreteevolved gas samples or, more commonly, may involve passingthe evolved gas through a heated flowcell during the TGAexperiment. The gene
5、ral techniques of TGA/IR and othercorresponding techniques, such as TGA coupled with massspectroscopy (TGA/MS), as well as, TGA, used in conjunctionwith GC/IR, are described in the referenced literature (1-4).21.3 Some thermal analysis instruments are designed toperform both thermogravimetric analys
6、is and differential scan-ning calorimetry simultaneously. This type of instrument issometimes called a simultaneous thermal analyzer (STA). Theevolved gas analysis performed with an STA instrument (5) issimilar to that with a TGA, and so, would be covered by thispractice. With use of a simultaneous
7、thermal analyzer, thecoupled method typically is labeled STA/IR.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This statement does not purport to address all of thesafety concerns, if any, associated with its use. It is
8、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E131 Terminology Relating to Molecular SpectroscopyE168 Practices for General Techn
9、iques of Infrared Quanti-tative AnalysisE334 Practice for General Techniques of Infrared Mi-croanalysisE473 Terminology Relating to Thermal Analysis and Rhe-ologyE1131 Test Method for CompositionalAnalysis by Thermo-gravimetryE1252 Practice for General Techniques for Obtaining Infra-red Spectra for
10、Qualitative AnalysisE1421 Practice for Describing and Measuring Performanceof Fourier Transform Mid-Infrared (FT-MIR) Spectrom-eters: Level Zero and Level One Tests3. Terminology3.1 DefinitionsFor general definitions of terms and sym-bols, refer to Terminologies E131 and E473.3.2 Definitions of Term
11、s Specific to This Standard:3.2.1 evolved gas, nany material (or mixture) evolvedfrom a sample during a thermogravimetric or simultaneousthermal analysis experiment. Materials evolved from thesample may be in the form of a gas, a vapor, an aerosol or asparticulate matter. For brevity, the term “evol
12、ved gas” will beused throughout this practice to indicate any material form ormixture evolved from a sample.3.2.2 evolved gas analysis (EGA), na technique in whichthe nature and amount of gas evolved from a sample ismonitored against time or temperature during a programmedchange in temperature of th
13、e sample.3.2.3 evolved gas profile (EGP), nan indication of thetotal amount of gases evolved, as a function of time ortemperature, during the thermogravimetric experiment. InTGA/IR, this profile is calculated from the infrared spectro-scopic data recorded by application of the Gram-Schmidt1This prac
14、tice is under the jurisdiction of ASTM Committee E13 on MolecularSpectroscopy and Separation Science and is the direct responsibility of Subcom-mittee E13.03 on Infrared and Near Infrared Spectroscopy.Current edition approved March 1, 2010. Published May 2010. Originallyapproved in 2000. Last previo
15、us edition approved in 2005 as E2105 00 (2005).DOI: 10.1520/E2105-00R10.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual B
16、ook of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.reconstruction (GSR) algorithm (6,7). Because the GSR wasdesigned for use in gas
17、 chromatography coupled with infrared(GC/IR) analysis, the evolved gas profile has sometimes beenerroneously called the evolved gas chromatogram.3.2.4 functional group profile (FGP), nan indication ofthe amount of gas evolved during the thermogravimetricexperiment that contains a particular chemical
18、 functionalitymeasured as a function of time or temperature. This profile iscalculated from the infrared spectroscopic data recorded byintegration of the absorbances over selected spectral regions asthe experiment progresses. Typically, a number of such profilesare calculated in real-time. Additiona
19、l profiles (using differentspectral regions) can often be calculated after the experimentfrom the stored spectroscopic data. Because the software usedhas similarities with that used for GC/IR analysis, the func-tional group profile has sometimes been erroneously called thefunctional group chromatogr
20、am.3.2.5 hit quality index (HQI), nthe numerical ranking ofinfrared reference spectra against that of an analyte spectrumthrough the use of search algorithms that measure a compara-tive fit spectral data.3.2.6 specific gas profile (SGP), na special type of func-tional group profile arises when the s
21、elected region of thespectrum contains absorbances due to a specific gas such asammonia or carbon monoxide.4. Significance and Use4.1 This practice provides general guidelines for the prac-tice of thermogravimetry coupled with infrared spectrometricdetection and analysis (TGA/IR). This practice assu
22、mes thatthe thermogravimetry involved in the practice is proper. It isnot the intention of this practice to instruct the user on properthermogravimetric techniques. Please refer to Test MethodE1131 for more information.5. General TGA/IR Techniques5.1 Two different types of TGA/IR techniques are used
23、 toanalyze samples. These consist of discrete evolved gas trap-ping and use of a heated flowcell interface. It should be notedthat only the latter technique allows for the calculation of theevolved gas and functional group profiles.5.2 Evolved Gas Trapping TechniquesEvolved gas trap-ping techniques
24、are the least elaborate means for obtainingTGA/IR data. In these techniques, the evolved gas is collectedfrom the TGA furnace in discrete aliquots that are thenanalyzed. In use of such techniques, it is essential to monitorthe TGA weight loss curve to determine the time or tempera-ture at which the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME210520002010STANDARDPRACTICEFORGENERALTECHNIQUESOFTHERMOGRAVIMETRICANALYSISTGACOUPLEDWITHINFRAREDANALYSISTGAIRTGAIR

链接地址:http://www.mydoc123.com/p-530289.html