ASTM E1817-2008(2014) Standard Practice for Controlling Quality of Radiological Examination by Using Representative Quality Indicators &40 RQIs&41 《使用典型质量指示仪(RQI)对放射性检查进行质量控制的标准实施规.pdf
《ASTM E1817-2008(2014) Standard Practice for Controlling Quality of Radiological Examination by Using Representative Quality Indicators &40 RQIs&41 《使用典型质量指示仪(RQI)对放射性检查进行质量控制的标准实施规.pdf》由会员分享,可在线阅读,更多相关《ASTM E1817-2008(2014) Standard Practice for Controlling Quality of Radiological Examination by Using Representative Quality Indicators &40 RQIs&41 《使用典型质量指示仪(RQI)对放射性检查进行质量控制的标准实施规.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1817 08 (Reapproved 2014)Standard Practice forControlling Quality of Radiological Examination by UsingRepresentative Quality Indicators (RQIs)1This standard is issued under the fixed designation E1817; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the radiological examination ofunique materials or p
3、rocesses, or both, for which convention-ally designed image quality indicators (IQIs), such as thosedescribed in Practices E747 and E1025, may be inadequate incontrolling the quality and repeatability of the radiologicalimage.1.2 Where appropriate, representative image quality indica-tors (RQIs) may
4、 also represent criteria levels of the acceptanceor rejection of images of discontinuities.1.3 This practice is applicable to most radiological methodsof examination.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of t
5、he user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E543 Specification for Agencies Performing NondestructiveTestingE747 Practice for Design, Manufacture and
6、Material Group-ing Classification of Wire Image Quality Indicators (IQI)Used for RadiologyE1000 Guide for RadioscopyE1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole-Type Image Quality In-dicators (IQI) Used for RadiologyE1316 Terminology for Nondestructive Examinat
7、ionsE1441 Guide for Computed Tomography (CT) Imaging2.2 ASNT Standards:3SNT-TC-1A Recommended Practice for Personnel Qualifi-cation in Nondestructive TestingANSI/ASNT CP-189 Standard for Qualification and Certifi-cation of Nondestructive Testing Personnel2.3 Aerospace Industries Association Document
8、:NAS 410 Certification and Qualification of NondestructiveTesting Personnel43. Terminology3.1 DefinitionsFor definitions of terms used in thispractice, refer to Terminology E1316.3.2 Definitions of Terms Specific to This Standard:3.2.1 representative quality indicator (RQI)a real part, ora fabricati
9、on of similar geometry in radiologically similarmaterial to a real part, that has features of known characteris-tics that represent those features of interest for which the partsto be purchased are being examined.4. Summary of Practice4.1 The information from an RQI image may be used tocontrol all o
10、f the parameters necessary for production exami-nation images (which look essentially like the RQI images) andis particularly effective in the practice of radioscopic andtomographic techniques. Refer to Guides E1000 and E1441,respectively.4.2 The designer may also use the RQI, when in compliancewith
11、 the requirements set out in this practice, to set accept orreject criteria, as applicable, to that part design.5. Significance and Use5.1 The use of RQIs is a significant departure from normalpractice in industrial radiology because it is not a standarddesign and is dependent on the application, ma
12、terial, andprocess and therefore cannot be a simple plaque or wire. Theuse of an RQI provides documented evidence that radiologicimages have the level of quality necessary to reveal those1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testingand is the direct respon
13、sibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved June 1, 2014. Published July 2014. Originally approvedin 1996. Last previous edition approved in 2008 as E1817 - 08. DOI: 10.1520/E1817-08R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org
14、, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, ht
15、tp:/www.asnt.org.4Available from Aerospace Industries Association of America, Inc. (AIA), 1000Wilson Blvd., Suite 1700,Arlington, VA22209-3928, http:/www.aia-aerospace.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1nonconformance
16、s for which the parts are being examined byensuring adequate spatial resolution and contrast sensitivity inthe areas of interest.5.2 Where conventional IQIs conforming to Practice E747or E1025 can be used effectively, those practices should befollowed.6. Basis of Application6.1 The following items s
17、hall be agreed upon between thepurchaser and the supplier and specified in the contract or joborder:6.1.1 Nondestructive testing (NDT) personnel shall bequalified in accordance with a nationally or internationallyrecognized NDT personnel qualification practice or standardsuch as ANSI/ASNT CP-189, SN
18、T-TC-1A, NAS 410, or asimilar document. The practice or standard used and itsapplicable revision shall be specified in the contractual agree-ment between the using parties.6.1.2 Nondestructive Testing Agency EvaluationIf a sys-tematic assessment of the capability of an NDT agency isspecified, a docu
19、mented procedure such as that described inPractice E543 shall be used as the basis for evaluation.6.1.3 Quality LevelsQuality levels to be used shall bespecified in accordance with 7.1 and 7.2.6.1.4 System Performance Using RQIsNonconformancesin RQIs used to determine system performance shall bespec
20、ified in accordance with 8.1.1 8.1.3.6.1.5 RQI FabricationThe design and manufacture ofRQIs shall be specified in accordance with 8.3.1 and 8.3.2.6.1.6 Frequency of RQI UsageIf not in accordance with8.7.1, the frequency of RQI usage shall be specified inaccordance with 8.7.2.6.1.7 Accept and Reject
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME181720082014STANDARDPRACTICEFORCONTROLLINGQUALITYOFRADIOLOGICALEXAMINATIONBYUSINGREPRESENTATIVEQUALITYINDICATORS40RQIS41

链接地址:http://www.mydoc123.com/p-529529.html