ASTM E1680-2011 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems《通过外部金属屋面板系统空气泄漏率的标准试验方法》.pdf
《ASTM E1680-2011 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems《通过外部金属屋面板系统空气泄漏率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1680-2011 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems《通过外部金属屋面板系统空气泄漏率的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1680 11Standard Test Method forRate of Air Leakage Through Exterior Metal Roof PanelSystems1This standard is issued under the fixed designation E1680; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the resis-tance of exterior metal roof panel systems to air infiltrationresulti
3、ng from either positive or negative air pressure differ-ences. The test method described is for tests with constanttemperature and humidity across the specimen. This testmethod is a specialized adaption of Test Method E283.1.2 This test method is applicable to any roof area. This testmethod is inten
4、ded to measure only the air leakage associatedwith the field of the roof, including the panel side laps andstructural connections; it does not include leakage at theopenings or perimeter or any other details.1.3 The proper use of this test method requires knowledgeof the principles of air flow and p
5、ressure measurements.1.4 The text of this test method references notes andfootnotes excluding tables and figures, which provide explana-tory material. These notes and footnotes shall not be consid-ered to be requirements of the test method.1.5 The values stated in inch-pound units are to be regarded
6、as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
7、this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2E283 Test Method for Determining Rate of Air LeakageThrough Exte
8、rior Windows, Curtain Walls, and DoorsUnder Specified Pressure DifferencesAcross the SpecimenE631 Terminology of Building ConstructionsE1592 Test Method for Structural Performance of SheetMetal Roof and Siding Systems by Uniform Static AirPressure DifferenceE1646 Test Method for Water Penetration of
9、 Exterior MetalRoof Panel Systems by Uniform Static Air PressureDifference2.2 Other Standards:AAMA 501 Methods of Test for Metal Curtain Walls33. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding construction used in this test method, see TerminologyE631.3.2 Definitions
10、of Terms Specific to This Standard:3.2.1 air leakage (Q)the volume of air flowing per unit oftime through the assembled specimen under a test pressuredifference, expressed in cubic feet per minute (cubic metres persecond).3.2.2 extraneous air leakage (QL)the difference betweenthe metered air flow (Q
11、m) and air leakage (Q); the leakage ofthe remainder of the test chamber.3.2.3 metered air flow (Qm)the volume of air flowing perunit of time through the air flow metering system, expressed incubic feet per minute (cubic metres per second).3.2.4 rate of air leakagethe air leakage per unit ofspecimen
12、area (A), expressed in cubic feet per minute persquare foot (cubic metres per second per square metre).3.2.5 reference standard conditionsdry air at a pressure of29.92 in. Hg (101.3 kPa), temperature of 69.4F (20.8C), andair density of 0.075 lb/ft3(1.2 kg/m3).3.2.6 specimenthe entire assembled unit
13、submitted fortesting as described in Section 8.3.2.7 specimen area (A)the area determined by the overalldimensions of the test specimen expressed in square feet(square metres). The dimensions used to determine area shallnot include exterior framework.1This test method is under the jurisdiction of AS
14、TM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.57on Performance of Metal Roof Systems.Current edition approved Nov. 1, 2011. Published November 2011. Originallyapproved in 1995. Last previous edition approved in 2003 as E1680 95 (2003).DOI: 10.1520/E
15、1680-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Architectural Aluminum Manufacturers
16、Association (AAMA),1827 Walden Office Square, Suite 550, Schaumburg, IL 60173, http:/www.aamanet.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.8 test pressure differencethe specified difference instatic air pressure across
17、the fixed specimen, expressed inpounds-force per square foot (pascals).4. Summary of Test Method4.1 The test procedure consists of sealing and fixing a testspecimen into or against one face of an air chamber, supplyingair to or exhausting air from the chamber at the rate required tomaintain the spec
18、ified test pressure difference across thespecimen, and measuring the resultant air flow through thespecimen.5. Significance and Use5.1 This test method is a standard procedure for determiningair leakage characteristics under specified air pressure differ-ences.NOTE 1The air pressure differences acti
19、ng across a building envelopevary greatly. The slope of the roof and other factors affecting air pressuredifferences and the implications of the resulting air leakage relative to theenvironment within buildings are discussed in the literature.4,5,6Thesefactors shall be considered fully when specifyi
20、ng the test pressuredifference to be used.NOTE 2When applying the results of tests by this test method, notethat the performance of a roof or its components, or both, may be afunction of proper installation and adjustment. The performance in servicewill also depend on the rigidity of supporting cons
21、truction, the presence ofinterior treatments, the roof slope, and the resistance of components todeterioration by various causes: corrosive atmospheres, aging, ice, vibra-tion, thermal expansion, and contraction, etc. It is difficult to simulate theidentical complex environmental conditions that can
22、 be encountered inservice, including rapidly changing pressures due to wind gusting. Somedesigns are more sensitive than others to these environmental conditions.5.2 Rates of air leakage are sometimes used for comparisonpurposes. The comparisons are not always valid unless thecomponents being tested
23、 and compared are of essentially thesame size, configuration, and design.NOTE 3The specimen construction discussed in 1.2 and required in8.1 isolates a source of leakage. The rate of air leakage measured duringthe test method has units of cubic feet per minute per square foot (litres persecond per s
24、quare metre). Openings and details such as end laps or roofcurbs are excluded since leakage is measured more appropriately in cubicfeet per minute per foot (litres per second per metre) at these conditions.The test specimen area is relatively small; the inclusion of details will giveunrealistic impo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16802011STANDARDTESTMETHODFORRATEOFAIRLEAKAGETHROUGHEXTERIORMETALROOFPANELSYSTEMS 通过 外部 金属 屋面板 系统

链接地址:http://www.mydoc123.com/p-529216.html