ASTM E1414 E1414M-2011ae1 Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum《共用一个天花板中通风系统的房间之间气载噪声衰减率的标准试验方法》.pdf
《ASTM E1414 E1414M-2011ae1 Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum《共用一个天花板中通风系统的房间之间气载噪声衰减率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1414 E1414M-2011ae1 Standard Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum《共用一个天花板中通风系统的房间之间气载噪声衰减率的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1414/E1414M 11a1Standard Test Method forAirborne Sound Attenuation Between Rooms Sharing aCommon Ceiling Plenum1This standard is issued under the fixed designation E1414/E1414M; the number immediately following the designation indicates the yearof original adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEResearch report number RR: E331033 was editorially corrected to RR: E331013 in October 2014.INTRODUCTION
3、This test method is designed to measure the sound attenuation provided by a suspended ceiling inthe presence of a continuous plenum space under prescribed laboratory test conditions. The testmethod is an adaptation ofAMA1-II-1967 Method of Test. This modified test method may give resultsdiffering fr
4、om the AMA-1-II procedure.1. Scope1.1 This test method utilizes a laboratory space so arrangedthat it simulates a pair of horizontally adjacent small offices orrooms separated by a partition and sharing a common plenumspace. The partition either extends to the underside of acommon plenum space or pe
5、netrates through it. In the pre-scribed configuration, special design features of the facilityensure that the only significant sound transmission path is byway of the ceiling and the plenum space.1.2 Within the limitations outlined in the significancestatement, the primary quantity measured by this
6、test method isthe ceiling attenuation of a suspended ceiling installed in alaboratory environment. By accounting for receiving roomsound absorption, the normalized ceiling attenuation may bedetermined.1.3 The test method may also be used to evaluate theattenuation of composite ceiling systems compri
7、sed of theceiling material and other components such as luminaires andventilating systems.1.4 The field performance of a ceiling system may differsignificantly from the results obtained by this test method (seeSection 5, Significance and Use, and Test Method E336).1.5 The procedures may also be used
8、 to study the additionalsound insulation that may be achieved by other attenuationmeasures. This would include materials used either as plenumbarriers or as backing for all or part of the ceiling.1.6 The facility may also be used to study the performanceof an integrated system comprising plenum, cei
9、ling, andpartition, tested as a single assembly.1.7 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from th
10、e two systems may result in non-conformancewith the standard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-
11、bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C423 Test Method for SoundAbsorption and SoundAbsorp-tion Coefficients by the Reverberation Room MethodC634 Terminology Relating to Building and EnvironmentalAcousticsC636 Practice for Installation of Metal Ceil
12、ing SuspensionSystems for Acoustical Tile and Lay-In PanelsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElementsE177 Practice for Use of the Terms Precision and Bias inASTM Test Methods1This test method is under the jurisdiction ofASTM Commi
13、ttee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved Nov. 1, 2011. Published December 2011. Originallyapproved in 1991. Last previous edition approved in 2011 as E1414 11. DOI:10.1520/E1414_E1414M11AE01.
14、2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
15、700, West Conshohocken, PA 19428-2959. United States1E336 Test Method for Measurement of Airborne SoundAttenuation between Rooms in BuildingsE413 Classification for Rating Sound InsulationE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ANSI Standar
16、ds:S1.11 Specification for Octave-Band and Fractional-OctaveBand Analog and Digital Filters32.3 Other Standards:AMA 1-II-1967 Method of Test, Standard Specification forCeiling Sound Transmission Test by Two Room Method43. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod see
17、 Terminology C634.3.2 Definitions of Terms Specific to This Standard:3.2.1 ceiling attenuation (Dc)the noise reduction betweenthe source and receiving rooms where flanking transmission byall paths are at least 10 decibels lower than the path through theceiling and plenum.Dc5 L12 L2(1)where L1is the
18、average one-third octave band sound pres-sure level in the source room; L2is the average one-thirdoctave band sound pressure level in the receiving room.3.2.2 normalized ceiling attenuation (Dn,c)the ceiling at-tenuation adjusted to account for receiving room absorption.Dn,c5 Dc1Nf(2)where Nfis the
19、normalization term defined in 3.2.3.3.2.3 normalization term(Nf)the adjustment term deter-mined in 9.3 which normalizes the ceiling attenuation toaccount for receiving room absorption.3.2.4 ceiling attenuation class (CAC)a single figure ratingderived from the normalized ceiling attenuation values in
20、accordance with Classification E413, except that the resultantrating shall be designated ceiling attenuation class.3.2.5 plenum spacethe whole of the void above thesuspended ceilings in both rooms. Its dimensions are to bemeasured, discounting the thickness of any sound absorbingmaterial either adhe
21、red to walls or laid on the back of the testceiling.3.2.6 direct sound fieldthe sound that results from anacoustical source without reflection from boundaries.3.2.7 reverberant sound fieldthe sound in an enclosed orpartially enclosed space that has been reflected repeatedly fromthe enclosure boundar
22、ies.4. Summary of Test Method4.1 The laboratory test facility consists of an outer shelldivided into two rooms by a partition and a suspended ceiling(the test specimen). The partition between the two rooms mayextend up to, or through, the suspended ceiling, dependingupon whether the specific test sp
23、ecimen is designed to becontinuous or interrupted at the partition line. The rooms arebuilt so that the only significant sound transmission pathbetween them is that provided by the test specimen and theceiling plenum. All other sound transmission paths must benegligible. The ceiling attenuation is d
24、etermined in each of thetest frequency bands, by placing a sound source in one roomand then calculating the difference of the average soundpressure levels in both rooms. For the purposes of this testmethod, the room containing the sound source is designated thesource room and the other, the receivin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1414E1414M2011AE1STANDARDTESTMETHODFORAIRBORNESOUNDATTENUATIONBETWEENROOMSSHARINGACOMMONCEILINGPLENUM

链接地址:http://www.mydoc123.com/p-528644.html