ASTM E1289-2008(2016) Standard Specification for Reference Specimen for Sound Transmission Loss《用于声音传输损失的参考试样的标准规格》.pdf
《ASTM E1289-2008(2016) Standard Specification for Reference Specimen for Sound Transmission Loss《用于声音传输损失的参考试样的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1289-2008(2016) Standard Specification for Reference Specimen for Sound Transmission Loss《用于声音传输损失的参考试样的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1289 08 (Reapproved 2016)Standard Specification forReference Specimen for Sound Transmission Loss1This standard is issued under the fixed designation E1289; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification describes the construction and instal-lation of standard reference specimens for quality control of
3、laboratory sound transmission loss measurements using TestMethod E90.1.2 Laboratories may choose to construct and test all of thereference specimens described here or only a subset. Specificspecimens may be required by a test method or an accreditingagency.1.3 The values stated in SI units are to be
4、 regarded asstandard. The values given in parentheses are for informationonly.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions andElements3.
5、Terminology3.1 DefinitionsFor definitions of terms used in thisspecification, see Terminology C634.4. Construction of Reference Specimen4.1 General:4.1.1 The reference specimen is composed of framed steelpanels. The required materials for fabrication and installationare as follows:Galvanized steel s
6、heetswidth, 1220 mm (4 ft); nominal thickness, 0.63 mm(24 gauge). The weight of the sheets shall be 5.1 0.7 kg/m2(1.05 0.15 lb/ft2).Steel right angles with 25-mm (1-in.) flangesmetal thickness, 3.2 mm (18 in.).Blind rivetsdiameter, 3.2 mm (18 in. ).Duct tape, 50 mm (2 in.) wide.Drywall screws, Type
7、Wlength, 32 mm (1.25 in.).Bolts #1024 25 mm (1 in.) long with appropriate nuts and washers.Fasteners, to hold wood frame to the perimeter of the test opening.Non-hardening, caulking,Nominal 2 by 4 in. wood framing, approximately 40 by 90 mm.NOTE 1The quantity and length of each component needed depe
8、ndson the size of the laboratory test opening.NOTE 1To simplify cleaning, the wood framing used to support thesteel panels may be painted.4.1.2 The weight of each component of the referencespecimen and the assembled specimen shall be measured andkept on record. In addition, the thickness of each of
9、the steelpanels shall be measured in six locations. (See Appendix X1.)4.2 Assembly:4.2.1 Galvanized SheetsThe length of each galvanizedsheet shall be a few millimetres less than the height of thelaboratory test opening. The total width of all the sheets shallbe a few millimetres less than the width
10、of the laboratory testopening. This may require that one or more sheets be cutlengthwise. The intent is that, when installed, the panels fill thetest opening completely.4.2.2 FrameCut steel right angles to size to form a framefor each sheet; the frame shall have the same outside dimen-sions as the s
11、heets. Notch and weld the steel angles to form thefour corners of the frame as shown in Fig. 1. Alternatively,miter the angles and weld similarly. Smooth corners afterwelding.4.2.3 PanelsConstruct a panel by riveting steel sheets tothe frames as follows:04.2.3.1 Drill holes at 100 mm (4 in.) on-cent
12、er around theperimeter of the sheets for the installation of the blind rivets. Toensure proper alignment of the sheets with the frame, it isrecommended to drill a few holes and then install rivets to holdthe sheet in place. Once this is done, the remaining holes maybe drilled and the rivets installe
13、d. Position these holes to avoidconflict with the clearance holes described in 4.2.3.2.4.2.3.2 Drill 4 mm (532 inch) diameter holes through thehorizontal members of the frame and sheet as shown in Fig. 2.These are clearance holes for the drywall screws used to attachthe panel to the wood plate (see
14、5.4). Drill similar holesthrough the vertical members of the panels that will be used toattach the assembled specimen to the vertical wood plates. Thespacing between these holes is not important.1This specification is under the jurisdiction of ASTM Committee E33 onBuilding and Environmental Acoustic
15、s and is the direct responsibility of Subcom-mittee E33.03 on Sound Transmission.Current edition approved May 1, 2016. Published May 2016. Originallyapproved in 1989. Last previous edition approved in 2008 as E1289 08. DOI:10.1520/E1289-08R16.2For referenced ASTM standards, visit the ASTM website, w
16、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2.
17、3.3 Drill 6.4 mm (14 in.) diameter holes at 406 mm (16in.) on-center through the vertical flanges of the steel frame.These are clearance holes for the bolts used to connect thepanels together (see 5.3 and Fig. 3). The holes in adjacentvertical members should be carefully aligned with each other toea
18、se installation of the panels.5. Installation A: Single Layer Reference Specimen5.1 Using approximately 40 mm by 90 mm wood studs(nominal 2 in. by 4 in.), install a wood frame around theperimeter of the laboratory opening. Use a double bead ofcaulking between the wood frame and the surface of thelab
19、oratory opening. Use suitable fasteners no more than 305mm (12 in.) on-center.5.2 Place the reference specimen against the wood framewith the flanges of the panel frames as shown in Fig. 4.NOTE 1The panels are positioned 75 mm from the mid-plane of thelaboratory test opening to minimize changes when
20、 laboratories intend totest other reference specimens described in this document that use separateplates.NOTE 2The direction of sound transmission for these referencespecimens is not important. It can be left-to-right or right-to-left.5.3 Insert 25-mm (1-in.) long No. 10-24 bolts or equivalentthroug
21、h the holes in adjacent vertical flanges drilled accordingto 4.2.3.3. Washers may be used if desired. Tighten nut snuglyto close the gap between adjacent panels. (See Fig. 3).5.4 Fasten the test panels to the vertical and horizontalsections of the wood frame with Type W drywall screws 32mm (1.25 in.
22、) long inserted through the holes drilled accordingto 4.2.3.2.5.5 Seal the test panel joints on both sides with a singlelayer of 50-mm (2-in.) wide duct tape (centered on the joints).5.6 Seal the perimeter joint on both sides with a single layerof 50-mm (2-in.) wide duct tape (centered on the joints
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME128920082016STANDARDSPECIFICATIONFORREFERENCESPECIMENFORSOUNDTRANSMISSIONLOSS 用于 声音 传输 损失 参考 试样

链接地址:http://www.mydoc123.com/p-528336.html