1、Designation: E1220 10Standard Practice forVisible Penetrant Testing UsingSolvent-Removable Process1This standard is issued under the fixed designation E1220; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2covers procedures for visible penetrantexamination utilizing the solvent-removable process. It is anondestructive tes
3、ting method for detecting discontinuities thatare open to the surface such as cracks, seams, laps, cold shuts,laminations, isolated porosity, through leaks, or lack of fusionand is applicable to in-process, final, and maintenance exami-nation. It can be effectively used in the examination ofnonporou
4、s, metallic materials, both ferrous and nonferrous,and of nonmetallic materials such as glazed or fully densifiedceramics and certain nonporous plastics and glass.1.2 This practice also provides a reference:1.2.1 By which a visible penetrant examination methodusing the solvent-removable process reco
5、mmended or requiredby individual organizations can be reviewed to ascertain itsapplicability and completeness.1.2.2 For use in the preparation of process specificationsdealing with the visible, solvent-removable liquid penetrantexamination of materials and parts. Agreement by the pur-chaser and the
6、manufacturer regarding specific techniques isstrongly recommended.1.2.3 For use in the organization of the facilities andpersonnel concerned with the liquid penetrant examination.1.3 This practice does not indicate or suggest standards forevaluation of the indications obtained. It should be noted,ho
7、wever, that after indications have been produced, they mustbe interpreted or classified and then evaluated. For this purposethere must be a separate code, specification, or a specificagreement to define the type, size, location, and direction ofindications considered acceptable, and those considered
8、 unac-ceptable.1.4 All areas of this practice may be open to agreementbetween the cognizant engineering organization and the sup-plier, or specific direction from the cognizant engineeringorganization.1.5 The values stated in inch-pound units are regarded asstandard. SI units given in parentheses ar
9、e for information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
10、 to use.2. Referenced Documents2.1 ASTM Standards:3D129 Test Method for Sulfur in Petroleum Products (Gen-eral Bomb Method)D516 Test Method for Sulfate Ion in WaterD808 Test Method for Chlorine in New and Used PetroleumProducts (Bomb Method)D1552 Test Method for Sulfur in Petroleum Products(High-Tem
11、perature Method)E165 Practice for Liquid Penetrant Examination for GeneralIndustryE433 Reference Photographs for Liquid Penetrant Inspec-tionE543 Specification for Agencies Performing Nondestruc-tive TestingE1316 Terminology for Nondestructive Examinations2.2 ASNT Documents:SNT-TC-1A Recommended Pra
12、ctice for Personnel Quali-fication and Certification in Nondestructive Testing4ANSI/ASNT-CP-189 Standard for Qualification and Certi-fication of NDT Personnel42.3 Military Standard:MIL-STD-410 Nondestructive Testing Personnel Qualifica-tion and Certification52.4 AIA Standard:1This practice is under
13、the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.03 on LiquidPenetrant and Magnetic Particle Methods.Current edition approved Feb. 15, 2010. Published March 2010. Originallyapproved in 1987. Last previous edition approved in 2005
14、as E1220 - 05. DOI:10.1520/E1220-10.2For ASME Boiler and Pressure Vessel Code applications see related TestMethod SE-1220 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStanda
15、rds volume information, refer to the standards Document Summary page onthe ASTM website.4Available from TheAmerican Society for Nondestructive Testing (ASNT), P.O.Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbi
16、ns Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NAS 410 Certification and Qualification of NondestructiveTest Personnel62.5 DoD Contracts-Unless otherwise specified, the issuesof the
17、documents that are DoD adopted are those listed in theissue of the DoDISS (Department of Defense Index of Speci-fications and Standards) cited in the solicitation.2.6 Order of Precedence-In the event of conflict betweenthe text of this practice and the references cited herein, the textof this practi
18、ce takes precedence.3. Terminology3.1 Definitionsdefinitions relating to liquid penetrant ex-amination, which appear in Terminology E1316, shall apply tothe terms used in this practice.4. Summary of Practice4.1 A liquid penetrant is applied evenly over the surfacebeing tested and allowed to enter op
19、en discontinuities. After asuitable dwell time, the excess surface penetrant is removed bywiping and the surface is dried. If an aqueous developer is tobe employed, the developer is applied prior to the drying step.A developer is then applied, drawing the entrapped penetrantout of the discontinuity,
20、 staining the developer. The test surfaceis then examined visually to determine the presence or absenceof indications.4.2 Processing parameters, such as precleaning, penetrationtime, etc., are determined by the specific materials used, thenature of the part under examination (that is, size, shape,su
21、rface condition, alloy), and type of discontinuities expected.5. Significance and Use5.1 Liquid penetrant examination methods indicate the pres-ence, location, and, to a limited extent, the nature and magni-tude of the detected discontinuities. This practice is intendedprimarily for portability and
22、for localized areas of examination,utilizing minimal equipment. Surface roughness may be alimiting factor. If so, an alternate process, such as water-washvisible or post-emulsified penetrant should be considered whengrinding or machining is not practical.6. Reagents and Materials6.1 Visible, Solvent
23、-Removable Liquid Penetrant TestingMaterials, (see Note 1) consist of a family of applicable visiblepenetrant, solvent remover, as recommended by the manufac-turer, and are classified as Type II Visible, Method CSolvent-Removable. Intermixing of materials from various manufac-turers is not recommend
24、ed. (WarningWhile approvedpenetrant materials will not adversely affect common metallicmaterials, some plastics or rubber may be swollen or stained bycertain penetrants.)NOTE 1Refer to 8.1 for special requirements for sulfur, halogen, andalkali metal content.6.2 Visible, Solvent-Removable Penetrants
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12202010STANDARDPRACTICEFORVISIBLEPENETRANTTESTINGUSINGSOLVENTREMOVABLEPROCESS 使用 可用 溶剂 清除 工艺 进行

链接地址:http://www.mydoc123.com/p-528198.html