1、Designation: E 1065 08Standard Guide forEvaluating Characteristics of Ultrasonic Search Units1This standard is issued under the fixed designation E 1065; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers measurement procedures for evaluat-ing certain characteristics of ultrasonic search units (alsoknown as “transducers”
3、) that are used with ultrasonic exami-nation instrumentation. This guide describes means for obtain-ing performance data that may be used to define the acousticand electric responses of ultrasonic search units.1.2 The procedures are designed to measure search units asindividual components (separate
4、from the ultrasonic test instru-ment) using commercial search unit characterization systemsor using laboratory instruments such as signal generators,pulsers, amplifiers, oscilloscopes, and waveform analyzers.1.3 The procedures are applicable to manufacturing accep-tance and incoming inspection of ne
5、w search units or toperiodic performance evaluation of search units throughouttheir service life.1.4 The procedures in Annex A1-Annex A6 are generallyapplicable to ultrasonic search units operating within the 0.4 to10 MHz range. Annex A7 is applicable to higher frequencyimmersion search unit evaluat
6、ion. Annex A8 describes a guidefor measuring sound beam profiles in metals from contactstraight-beam search units. Additional Annexes, such as soundbeam profiling for angle-beam search units in metal andalternate means for search unit characterization, will be addedwhen developed.1.5 The values stat
7、ed in inch-pound units are to be regardedas standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility o
8、f regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 1316 Terminology for Nondestructive Examinations2.2 Other Document:Standard Methods for Testing Single Element Pulse-EchoUltrasonic Transducers33. Terminology3.1 DefinitionsFor definitions of terms used in this guide,
9、see Terminology E 1316.3.2 Definitions of Terms Specific to This Standard:3.2.1 aperturethe dimension(s) of the active area of thepiezoelectric element of the search unit as established byexperimentation.3.2.2 bandwidth (BW) that portion of the frequencyresponse that falls within given limits. In th
10、is text, the limitsused are the -6 dB level, as measured from the peak of thefrequency response. The equation used for BW is:BW 5 fu2 f1!/fc3 100 (1)where:fu= upper frequency,f1= lower frequency, andfc= center frequency.Bandwidth is expressed as a percentage.3.2.3 center frequency (fc)the frequency
11、value calculatedto be at the center of the bandwidth limits.3.2.4 depth of field (FD)as measured on the on-axis profileof a focused search unit, that portion of the sound beam thatfalls within given limits.3.2.5 focal length (FL)for focused search units, the dis-tance from the lens to the focal poin
12、t.3.2.6 focal point (Fp)for focused search units, the pointalong the acoustic axis of the beam in water at which the peak(maximum) pulse-echo amplitude response is recorded from aball target reflector.3.2.7 frequency responsethe pulse-echo response of thesearch unit measured as a function of frequen
13、cy. (This termalso referred to as frequency spectrum.)3.2.8 nominal frequency (fnom)the frequency stated on thelabel supplied by the manufacturer.3.2.9 on-axis profilea sequence of measurements madealong the acoustic axis of the beam of the search unit.3.2.10 peak frequency (fp)the frequency value a
14、t themaximum amplitude of the frequency response.1This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.06 on UltrasonicMethod.Current edition approved July 1, 2008. Published July 2008. Originally approvedin 1985.
15、Last previous edition approved in 2003 as E 1065 99(2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Av
16、ailable from the American Institute of Ultrasonics in Medicine, 14750Sweitzer Lane, Suite 100, Laurel, MD 20707-5906.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.11 pulse durationthe length of the sinusoidal burstused to excit
17、e the search unit as expressed in time or numberof cycles (sometimes referred to as tone-burst).3.2.12 pulse echo sensitivitya measurement that comparesthe amplitude of the applied voltage with the amplitude of thepulse-echo voltage recorded from a specified target.3.2.13 shock excitationa short ele
18、ctrical impulse that isapplied to the search unit. The impulse is typically a negative-going voltage spike of fast rise time and short duration.3.2.14 transverse profilesequence of measurements madealong a line perpendicular to the acoustic axis of the beam ofthe search unit.3.2.15 waveform duration
19、the time interval or durationover which the unrectified signal or echo from a specifiedtarget exceeds a selected amplitude level as related to themaximum amplitude of the signal or echo (for example, 20or 40 dB).4. Summary of Guide4.1 The acoustic and electrical characteristics which can bedescribed
20、 from the data obtained by procedures outlined in thisguide are described as follows:4.1.1 Frequency ResponseThe frequency response maybe obtained from one of two procedures: (a) shock excitationand (b) sinusoidal burst. Annex A1 describes procedures forobtaining frequency response for immersion and
21、 zero-degreecontact search units. Annex A2 describes the procedure forobtaining bandwidth characteristics.4.1.2 Relative Pulse-Echo Sensitivity (Srel)The relativepulse-echo sensitivity may be obtained from the frequencyresponse data obtained using the sinusoidal burst proceduredescribed in Annex A1.
22、 The value is obtained from therelationship of the amplitude of the voltage applied to thesearch unit and the amplitude of the pulse-echo signal receivedfrom a specified target. Annex A3 describes the procedure forobtaining pulse-echo sensitivity.NOTE 1Values for applied and received power, from whi
23、ch insertionloss might be determined are not covered with procedures described in thisguide.4.1.3 Time ResponseThe time response provides a meansfor describing the radio frequency (rf) response of the wave-form. A shock excitation, pulse-echo procedure is used toobtain the response. The time or wave
24、form responses arerecorded from specific targets that are chosen for the type ofsearch unit under evaluation (for example, immersion, contactstraight beam, or contact angle beam). Annex A4 describes theprocedures for measuring time response.4.1.4 Electrical Impedance:4.1.4.1 Complex Electrical Imped
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10652008488STANDARDGUIDEFOREVALUATINGCHARACTERISTICSOFULTRASONICSEARCHUNITS 评估 超声波 探测 装置 特性 标准 指南

链接地址:http://www.mydoc123.com/p-527844.html