1、Designation: E 72 05Standard Test Methods ofConducting Strength Tests of Panels for BuildingConstruction1This standard is issued under the fixed designation E 72; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONSound engineering design of structures using
3、 existing or new materials requires accurate technicaldata on the strength and rigidity of the basic elements employed in various construction systems. It isthe purpose of these test methods to provide a systematic basis for obtaining engineering data onvarious construction elements and structural d
4、etails of value to designers, builders, building officials,and others interested in this field. The results should closely approximate the performance in actualservice.1. Scope1.1 These test methods cover the following procedures fordetermining the structural properties of segments of wall, floor,an
5、d roof constructions:SectionTest Specimens 3Loading 4Deformation Measurements 5Reports 6Precision and Accuracy 7TESTING WALLSSignificance and Use 8Compressive Load 9Tensile Load 10Transverse LoadSpecimen Horizontal 11Transverse LoadSpecimen Vertical 12Concentrated Load 13Impact LoadSee Test Methods
6、E 695 andE 661Racking LoadEvaluation of SheathingMaterials on a Standard Wood Frame14Racking LoadEvaluation of SheathingMaterials (Wet) on a Standard WoodFrame15TESTING FLOORSSignificance and Use 16Transverse Load 17Concentrated Load 18Impact LoadSee Test Methods E 695 andE 661TESTING ROOFSSectionSi
7、gnificance and Use 19Transverse Load 20Concentrated Load 21APPENDIXTechnical Interpretation Appendix X11.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.2. Referenced Documents2.1 ASTM Standards:2E4 Practices for Force Verifi
8、cation of Testing MachinesE73 Practice for Static Load Testing of Truss AssembliesE 564 Practice for Static Load Test for Shear Resistance ofFramed Walls for BuildingsE 575 Practice for Reporting Data from Structural Tests ofBuilding Constructions, Elements, Connections, and As-sembliesE 661 Test Me
9、thod for Performance of Wood and Wood-Based Floor and Roof Sheathing Under ConcentratedStatic and Impact LoadsE 695 Test Method of Measuring Relative Resistance ofWall, Floor, and Roof Constructions to Impact LoadingE 2322 Test Method for Conducting Traverse and Concen-trated Load Tests on Panels us
10、ed in Floor and RoofConstruction3. Test Specimens3.1 SizeThere shall be at least three specimens for eachtest. Specimens shall be constructed to represent sections of the1These test methods are under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and are the direct responsibility
11、of Subcommittee E 06.11on Horizontal and Vertical Structures/Structural Performance of Completed Struc-tures.Current edition approved May 1, 2005. Published May 2005. Originallyapproved in 1947. Last previous edition approved in 2004 as E 72 04.2For referenced ASTM standards, visit the ASTM website,
12、 www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.w
13、all, floor, or roof assembly. The specimens shall be represen-tative as to material and workmanship and shall be of thelargest practical size to predict structural performance at-tributes of the assembly. Unsymmetrical assemblies shall betested in each axis for which the results may be different.3.2
14、 Length or HeightThe length or height of specimen foreach element shall be chosen to conform to the length or heightof that element in actual use.3.3 WidthThe width of specimen shall be chosen, insofaras possible, to include several of the principal load-carryingmembers to ensure that the behavior u
15、nder load will simulatethat under service conditions. With the exception of specimensfor the racking load test, the nominal width of wall specimensshall be 1.2 m (4 ft). The actual width of specimens shall be awhole number multiplied by the spacing of the principalload-carrying members except for pr
16、efabricated panels, forwhich the actual width shall be the width of panel used. If thestructural properties of a particular construction are to becompared with another construction, there should not be agreat difference in the actual widths of the specimens.3.4 AgeConstructions, such as concrete and
17、 masonry(brick, structural clay tile, concrete block) for which thestructural properties depend upon the age of the specimen,shall be tested not less than 25 days nor more than 31 days afterfabrication. This age requirement applies also to plastered andstuccoed constructions.4. Loading4.1 ApparatusT
18、he testing machine or load-measuring ap-paratus shall comply with the requirements prescribed inMethods E4.4.2 Application of LoadApply the load to all of thespecimens in any test in increments so chosen that a sufficientnumber of readings will be obtained to determine definitely theload-deformation
19、 curve (see Section 6). Record the initialreading of the load and the reading of the deformation, eitherwith no load on the specimen or under a small initial load.Increase the load to the first increment and record the defor-mation. Unless otherwise specified, decrease the load to theinitial load an
20、d record the set (sometimes designated “perma-nent set”). Increase the load to two increments and record theset, when it is released to the initial load. Follow this sequenceof readings for three increments, four increments, and so forth,of load. When for each specimen the behavior of the specimenun
21、der load indicates that the specimen might fail suddenly anddamage the deformation-measuring apparatus, remove thisapparatus from the specimen and increase the load continu-ously until the maximum load that can be applied to thespecimen is determined.4.3 Duration of Load ApplicationExcept for rackin
22、g tests,after each increment of load is applied, maintain the load levelas constant as possible for a period of 5 min (see Note 1). Takedeformation readings as soon as practical after load applica-tion, at the end of the 5-min period under constant load, andimmediately and at the end of the 5-min pe
23、riod after any partialor complete load release. Plot initial and 5-min readings in theform of load-deformation curves. Maintain complete load-deformation-time records throughout the test. If application ofa given load is required for a certain period, such as 24 h, takedeformation readings at the be
24、ginning, at intervals during thisperiod, and at the end of this period, to allow the satisfactoryplotting of a time-deformation curve for the complete period.NOTE 1Reasons for the 5-min application of constant-level incrementloads are as follows:(1) To permit the assembly to come to a substantial re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME722005STANDARDTESTMETHODSOFCONDUCTINGSTRENGTHTESTSOFPANELSFORBUILDINGCONSTRUCTION 建筑工程 板条 传导 强度

链接地址:http://www.mydoc123.com/p-527611.html