ASTM E276-2013 red 8173 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Finer for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及较细筛进行.pdf
《ASTM E276-2013 red 8173 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Finer for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及较细筛进行.pdf》由会员分享,可在线阅读,更多相关《ASTM E276-2013 red 8173 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Finer for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及较细筛进行.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E276 03 (Reapproved 2008)1E276 13Standard Test Method forParticle Size or Screen Analysis at No. 4 (4.75-mm) Sieveand Finer for Metal-Bearing Ores and Related Materials1This standard is issued under the fixed designation E276; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEEditorial corrections were made throughout in September
3、 2008.1. Scope1.1 This test method covers the determination of the size distribution by screen analysis, dry or wet, of metal-bearing ores andrelated materials at No. 4 (4.75-mm) sieve and finer.1.2 The values stated in inch-pound units are to be regarded as standard. The SI values given in parenthe
4、ses are provided forinformation only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the
5、applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and Test SievesE135 Terminology Relating to Analytical Chemistry for Metals, Ores, and Related MaterialsE882 Guide for Accountability and Quality Control i
6、n the Chemical Analysis Laboratory3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, refer to Terminology E135.4. Summary of Test Method4.1 The sample is passed through a bank of standard sieves by agitation. The dry screening technique described in this testmetho
7、d may be used on any solid particles that can be dried so that sieve blinding does not occur. The wet screening techniqueusing liquid media may be used on any insoluble solids.5. Significance and Use5.1 This test method is intended to be used for compliance with compositional specifications for part
8、icle size distribution. It isassumed that all who use this procedure will be trained analysts capable of performing common laboratory practices skillfully andsafely. It is expected that work will be performed in a properly equipped laboratory and that proper waste disposal procedures willbe followed
9、. Follow appropriate quality control practices such as those described in Guide E882.6. Apparatus and Materials6.1 U.S. Standard Sieves, conforming to the requirements of Specification E11.6.2 Mechanical Sieve Shaker.6.3 Drying Oven, of appropriate size and capable of maintaining a uniform temperatu
10、re at 110 C 6 5 C.110 C 6 5 C.1 This test method is under the jurisdiction of ASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials and is the direct responsibility ofSubcommittee E01.02 on Ores, Concentrates, and Related Metallurgical Materials.Current edition approved
11、Sept. 1, 2008Oct. 1, 2013. Published September 2008November 2013. Originally approved in 1965. Last previous edition approved in 20032008as E276 03.E276 03 (2008)1. DOI: 10.1520/E0276-03R08E01.10.1520/E0276-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Custom
12、er Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the
13、previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright AST
14、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.4 Sample Splitter or Riffle with 1-in. (25.4-mm) opening.6.5 Scales and Weights, of adequate accuracy.6.6 Pans, for holding samples.6.7 Brass and Fiber Bristle Brushes, for cleaning sieves and pans
15、.6.8 Special Apparatus, for wet screening, including deep-frame sieves.6.9 Water or other liquid, for wet screening.7. Sample Preparation7.1 If necessary, reduce the sample by riffling or other suitable means to obtain a test sample that will not overload the sieves,and dry at 110 C 6 5 C to constan
16、t weight. 110 C 6 5 C to constant mass. Constant mass is obtained when an additional hourdrying at 110 C 6 5 C does not cause a change greater than 0.05 % mass.NOTE 1The size of the sample is very important in sieve analysis because the number of particles on a sieve surface affects the probability
17、of anyone particle passing through the sieve at a given time. The more particles there are on a sieve, the greater probability that any one particle is hinderedfrom getting into a position to pass through the opening. Avoid overloading the sieves.7.2 Screen the test sample from 7.1 on a No. 4 (4.75-
18、mm) sieve. Weigh the material retained on the No. 4 sieve. Record mass.8. Preparation of Apparatus8.1 Clean coarse sieves up to No. 80 (180 m) with a soft brass wire brush and clean the finer sieves with a fiber brush. Cleanby brushing the under side of the sieves. Gently tap the brass frame to aid
19、in freeing trapped particles.At times, it may be necessaryto wash the sieves in a warm soap and water solution. After washing, dry the sieves thoroughly. If wet screening is to be used,nest selected special deep-frame sieves after cleaning as described.NOTE 2As an alternative, ultrasonic cleaning of
20、 sieves is recommended.9. Standardization of Sieves9.1 Calibrate the sieves by use of calibrated glass spheres. Standard glass spheres are available through the National Instituteof Standards and Technology (NIST) and other international standardization organizations.9.2 Use of the microscopic metho
21、d in the appendix of Specification E11 is also permissible to assure that the sieves meetspecification.10. Procedure10.1 Dry Screening:10.1.1 For Samples Containing Less than 10 % 10 % Passing a No. 200 (75-m) SieveNest the selected sieves and fit a panbelow the bottom sieve. Place the material whic
22、h passed the No. 4 (4.75-mm) sieve from 7.2, in the top sieve. Cover and clampthe nested sieves in the mechanical shaker and shake for the time interval specified in 10.1.3.10.1.2 For Samples Containing More than 10 % 10 % Passing a No. 200 (75-m) SieveWash the material which passed theNo. 4 (4.75-m
23、m) sieve from 7.2 on a No. 200 (75-m) sieve until the solution passing through the sieve is clear (see 10.2). Savethe material passing the sieve. Dry the sieve fractions in accordance with 10.2.4.2 and process the retained fraction in accordancewith 10.1.1.10.1.3 Length of Screening Time or End Poin
24、tThe screening time or end point is when additional periods of shaking fail tochange the results on any sieve used in the test by more than 0.3 %. The screening time may vary from 3 min to 30 min or moredepending on the type of material. Determine the exact time for each material experimentally.10.1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2762013RED8173STANDARDTESTMETHODFORPARTICLESIZEORSCREENANALYSISATNO4475MMSIEVEANDFINERFORMETALBEARINGORESANDRELATEDMATERIALS

链接地址:http://www.mydoc123.com/p-527284.html