《ASTM D7363-2013 4375 Standard Test Method for Determination of Parent and Alkyl Polycyclic Aromatics in Sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography.pdf》由会员分享,可在线阅读,更多相关《ASTM D7363-2013 4375 Standard Test Method for Determination of Parent and Alkyl Polycyclic Aromatics in Sediment Pore Water Using Solid-Phase Microextraction and Gas Chromatography.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7363 13Standard Test Method forDetermination of Parent and Alkyl Polycyclic Aromatics inSediment Pore Water Using Solid-Phase Microextractionand Gas Chromatography/Mass Spectrometry in SelectedIon Monitoring Mode1,2This standard is issued under the fixed designation D7363; the number i
2、mmediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 T
3、he U.S. Environmental Protection Agency (USEPA)narcosis model for benthic organisms in sediments contami-nated with polycyclic aromatic hydrocarbons (PAHs) is basedon the concentrations of dissolved PAHs in the interstitialwater or “pore water” in sediment. This test method covers theseparation of p
4、ore water from PAH-impacted sedimentsamples, the removal of colloids, and the subsequent measure-ment of dissolved concentrations of the required 10 parentPAHs and 14 groups of alkylated daughter PAHs in the porewater samples. The “24 PAHs” are determined using solid-phase microextraction (SPME) fol
5、lowed by GasChromatography/Mass Spectrometry (GC/MS) analysis in se-lected ion monitoring (SIM) mode. Isotopically labeled ana-logs of the target compounds are introduced prior to theextraction, and are used as quantification references.1.2 Lower molecular weight PAHs are more water solublethan high
6、er molecular weight PAHs. Therefore, USEPA-regulated PAH concentrations in pore water samples varywidely due to differing saturation water solubilities that rangefrom 0.2 g/L for indeno1,2,3-cdpyrene to 31 000 g/L fornaphthalene. This method can accommodate the measurementof microgram per litre conc
7、entrations for low molecular weightPAHs and nanogram per litre concentrations for high molecularweight PAHs.1.3 The USEPA narcosis model predicts toxicity to benthicorganisms if the sum of the toxic units (TUc) calculated for all“34 PAHs” measured in a pore water sample is greater than orequal to 1.
8、 For this reason, the performance limit required forthe individual PAH measurements was defined as the concen-tration of an individual PAH that would yield134 of a toxic unit(TU). However, the focus of this method is the 10 parent PAHsand 14 groups of alkylated PAHs (Table 1) that contribute 95 %of
9、the toxic units based on the analysis of 120 background andimpacted sediment pore water samples.3The primary reasonsfor eliminating the rest of the 5-6 ring parent PAHs are: (1)these PAHs contribute insignificantly to the pore water TU, and(2) these PAHs exhibit extremely low saturation solubilities
10、that will make the detection of these compounds difficult inpore water. This method can achieve the required detectionlimits, which range from approximately 0.01 g/L, for highmolecular weight PAHs, to approximately 3 g/L for lowmolecular weight PAHs.1.4 The test method may also be applied to the det
11、ermina-tion of additional PAH compounds (for example, 5- and 6-ringPAHs as described in Hawthorne et al.).4However, it is theresponsibility of the user of this standard to establish thevalidity of the test method for the determination of PAHs otherthan those referenced in 1.1 and Table 1.1.5 This st
12、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatem
13、ents, refer to Section 9.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved March 15, 2013. Published May 2013. Originallyapproved in 2007. La
14、st previous edition approved in 2011 as D7363 11. DOI:10.1520/D7363-13.2Standard methods under the jurisdiction of ASTM Committee D19 may bepublished for a limited time preliminary to the completion of full collaborative studyvalidation. Such standards are deemed to have met all other D19 qualifying
15、requirements but have not completed the required validation studies to fullycharacterize the performance of the test method across multiple laboratories andmatrices. Preliminary publication is done to make current technology accessible tousers of standards, and to solicit additional input from the u
16、ser community.3Hawthorne, S. B., Grabanski, C. B., and Miller, D. J., “Measured PartitioningCoefficients for Parent and Akyl Polycyclic Aromatic Hydrocarbons in 114Historically Contaminated Sediments: Part I, Koc Values,” Environmental Toxicol-ogy and Chemistry, Vol 25, 2006, pp. 29012911.4Hawthorne
17、, S. B., Grabanski, C. B., Miller, D. J., and Kreitinger, J. P., “SolidPhase Microextraction Measurement of Parent and Akyl Polycyclic AromaticHydrocarbons in Milliliter Sediment Pore Water Samples and Determination ofKDOCValues,” Environmental Science Technology, Vol 39, 2005, pp. 27952803.Copyrigh
18、t ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:5D1192 Guide for Equipment for Sampling Water and Steamin Closed Conduits (Withdrawn 2003)6D1193 Specification for Reagent WaterD2777 Practice for Deter
19、mination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsE178 Practice for Dealing With Outlying Observations3. Terminology3.1 Definitions:3.1.1 calibration standarda solution prepared from a sec-ondary standard, stock s
20、olution, or both, and used to calibratethe response of the instrument with respect to analyte concen-tration.3.1.2 calibration verification standard (VER)the mid-point calibration standard (CS3) that is analyzed daily to verifythe initial calibration.3.1.3 CS1, CS2, CS3, CS4shorthand notation for ca
21、libra-tion standards.3.1.4 data acquisition parametersparameters affecting thescanning operation and conversion of the analytical signal todigitized data files. These include the configuration of theADCcircuitry, the ion dwell time, the MID cycle time, and acqui-sition modes set up for the method. E
22、xamples of acquisitionmodes for the HP5973 include SIM mode, and Low MassResolution Mode.3.1.5 performance limitperformance limit for an indi-vidual PAH is defined as the concentration of an individualPAH that would yield134 of a toxic unit. For a performancelimit of an individual PAH, refer to Tabl
23、e 1.3.1.6 deuterated PAH (d-PAH)polycyclic aromatic hydro-carbons in which deuterium atoms are substituted for allhydrogens (that is, perdeuterated). In this method, d-PAHs areused as internal standards.3.1.7 GCgas chromatograph or gas chromatography.3.1.8 HRGChigh resolution GC.3.1.9 LRMSlow resolu
24、tion MS.3.1.10 internal standardsisotopically labeled analogs (d-PAHs) of the target analytes that are added to every sample,blank, quality control spike sample, and calibration solution.They are added to the water samples immediately aftercompleting the flocculation step and transferring the watera
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD736320134375STANDARDTESTMETHODFORDETERMINATIONOFPARENTANDALKYLPOLYCYCLICAROMATICSINSEDIMENTPOREWATERUSINGSOLIDPHASEMICROEXTRACTIONANDGASCHROMATOGRAPHYPDF

链接地址:http://www.mydoc123.com/p-525279.html