ASTM D7232-2006 Standard Test Method for Rapid Determination of the Nonvolatile Content of Coatings by Loss in Weight《重量损耗的覆层非挥发物含量的快速测试方法》.pdf
《ASTM D7232-2006 Standard Test Method for Rapid Determination of the Nonvolatile Content of Coatings by Loss in Weight《重量损耗的覆层非挥发物含量的快速测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7232-2006 Standard Test Method for Rapid Determination of the Nonvolatile Content of Coatings by Loss in Weight《重量损耗的覆层非挥发物含量的快速测试方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7232 06Standard Test Method forRapid Determination of the Nonvolatile Content of Coatingsby Loss in Weight1This standard is issued under the fixed designation D 7232; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to obtain rapid determination ofthe weight percent nonvolatile (solids) content v
3、ia instrumentalloss in weight technology. It is not meant as a replacement forTest Method D 2369.1.2 This test method is principally intended for qualitycontrol labs and manufacturing environments where previouslycharacterized materials will be tested repeatedly for differentbatches or lots.1.3 This
4、 test method can be used for waterborne andsolventborne resins, intermediates and finished paint products.This test method may not be applicable to all types of coatings.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 T
5、his standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.NOTE 1There is no s
6、imilar or equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:2D16 Terminology for Paint, Related Coatings, Materials,and ApplicationsD 2369 Test Method for Volatile Content of CoatingsE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial an
7、d Spe-cialty Chemicals3. Terminology3.1 DefinitionsThe definitions used in this test method arein accordance with Terminology D16.3.1.1 nonvolatile content, nthe coating material that re-mains in the pan at the conclusion of the test.3.2 Definitions of Terms Specific to This Standard:3.2.1 flip and
8、squish, na testing technique that may beused when the expected nonvolatile content is greater than40 %, or when the sample is highly viscous and does notabsorb well into the filter paper.3.2.1.1 DiscussionThe specimen is applied to the filterpaper on the sample pan, the filter paper is “flipped” ove
9、r andthe specimen is then “squished” between the filter paper andthe sample pan in order to more uniformly distribute thespecimen. In addition, use of this technique forces the glassfibers of the filter paper into the specimen, helping to createpathways for volatiles release from the specimen and av
10、oidingincomplete volatiles removal due to “skinning over” of thesample material.3.2.2 lift, nthe result of convection currents created dur-ing the heating of the specimen that raises the sample pan offof its support and falsely indicates a weight loss.3.2.2.1 DiscussionThis effect is compensated for
11、 by theuse of an algorithm that is applied to the digital data.3.2.3 syringe tare, na testing technique that may be usedwhen the expected nonvolatile content is less than 40 %, orwhen the sample is highly volatile and tends to evaporaterapidly.3.2.3.1 DiscussionThe specimen weight is determinedusing
12、 an external balance by calculating the difference betweenthe syringe weight before (initial weight) and after (finalweight) the specimen is applied to the pan. This differencebetween initial and final weight is the actual weight ofspecimen (see 10.2), and is used to minimize error due to rapidchang
13、e of the specimen weight after addition to a heatedsample pan.4. Summary of Test Method4.1 The specimen is spread onto a sample pan that issupported on a balance in a heating chamber that has beenpreheated and equilibrated to the specified idle temperature. Itis then heated to the specified test tem
14、perature to vaporize thevolatiles. The analysis is completed when the indicated rate ofweight loss falls below a rate specified in the test conditions.The total weight loss is calculated and reported as weight1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coati
15、ngs, Materials, andApplications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June 1, 2006. Published June 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service a
16、t serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.percent nonvolatiles. Both the analyzers balance
17、and heaterare calibrated with NIST-traceable standards to achieve preciseand accurate results.4.2 Through adjustment of the analyzers parameter set-tings, a set of optimal conditions is developed for each materialtype to measure the percent nonvolatiles. These optimalconditions are recorded and may
18、be used for repeat testing ofthat material.5. Significance and Use5.1 This test method is intended for use as a rapid qualitycontrol, acceptance, and assessment test. Results are obtainedin five to fifteen minutes on most materials. Since the instru-ment parameters are adjusted to produce the same r
19、esults asTest Method D 2369, which takes over one hour to run, thetime and effort expended on determining the optimal condi-tions for testing a coating with this instrumental method isvaluable when numerous measurements are going to be madeon different lots or batches of the same material. Also, the
20、automation of the measurement and the calculations shouldlead to fewer mistakes being made by less-trained operators.6. Apparatus6.1 Analyzer, containing:6.1.1 An oven capable of heating the sample to at least225C.6.1.2 A balance capable of measuring to the nearest 0.0001g.6.1.3 An electronic means
21、of compensating for lift causedby convection currents created during testing.6.1.4 A processor that is capable of converting the loss ofweight to digital data.6.1.5 Digital display for presenting the digital data asweight percent nonvolatiles.6.2 Flat disposable pan, of aluminum alloy 3003, withsmoo
22、th, uncoated, oil-free surface.6.3 Round glass-fiber filter paper, Grade 111.6.4 Syringe, 3 cc plastic slip-tip without needle but withcap, capable of dispensing specimen onto pan.6.5 Nitrogen compressed gas (N2) dry and oil-free.6.6 Compressed gas regulator(s), as needed to supply N2from high-press
23、ure sources to controlled delivery pressuresthat are appropriate for the apparatus.7. Reagents7.1 Sodium Tartrate DihydrateACS certified reagentgrade.8. Calibration and Standardization8.1 To maintain the integrity of the test results, the balanceshall be calibrated using NIST-traceable weights and t
24、he heatershall be calibrated using an NIST-traceable temperature cali-bration interface per the analyzer manufacturers guidelines.8.2 The calibration may be verified using sodium tartratedihydrate, which has a theoretical water content of 15.66 %,with an acceptable result range of 15.61 to 15.71 %.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72322006STANDARDTESTMETHODFORRAPIDDETERMINATIONOFTHENONVOLATILECONTENTOFCOATINGSBYLOSSINWEIGHT 重量

链接地址:http://www.mydoc123.com/p-524888.html