ASTM D7011-2015 red 4750 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《采用气相色谱法和硫化选择检测法测定精制苯中微量噻吩.pdf
《ASTM D7011-2015 red 4750 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《采用气相色谱法和硫化选择检测法测定精制苯中微量噻吩.pdf》由会员分享,可在线阅读,更多相关《ASTM D7011-2015 red 4750 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《采用气相色谱法和硫化选择检测法测定精制苯中微量噻吩.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7011 10aD7011 15Standard Test Method forDetermination of Trace Thiophene in Refined Benzene byGas Chromatography and Sulfur Selective Detection1This standard is issued under the fixed designation D7011; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of thiophene in refined
3、 benzene using gas chromatography and sulfur selectivedetection. The test method is applicable to the determination of thiophene at levels of 0.02 to 2.18 mg thiophene per kg in benzene(mg/kg) on the AED, 0.03 to 1.87 mg/kg on the PFPD, and 0.03 to 2.11 mg/kg on the SCD. The range of the test method
4、 maybe extended by modifying the sample injection volume, split ratios, calibration range, or sample dilution with thiophene-freesolvent.1.2 In determining the conformance of the test results using this method to applicable specifications, results shall be roundedoff in accordance with the rounding-
5、off method of Practice E29.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of t
6、his standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific hazard statements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1685 Test Method for Traces of Thiop
7、hene in Benzene by Spectrophotometry (Withdrawn 2009)3D2359 Specification for Refined Benzene-535D3437 Practice for Sampling and Handling Liquid Cyclic ProductsD4734 Specification for Refined Benzene-545D4735 Test Method for Determination of Trace Thiophene in Refined Benzene by Gas ChromatographyD5
8、871 Specification for Benzene for Cyclohexane FeedstockD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related MaterialsE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE177 Practice for Use of the Terms
9、 Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE1510 Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and
10、 1910.120033. Summary of Test Method3.1 The thiophene concentration in refined benzene is determined at the sub-mg/kg to low mg/kg level using conventional gaschromatography with a sulfur selective detector. A reproducible volume of sample is injected. Quantitative results are obtained bythe use of
11、the external standard calibration technique.1 This test method is under the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons and Related Chemicals and is the direct responsibility of SubcommitteeD16.04 on Instrumental Analysis.Current edition approved Dec. 1, 2010June 1, 2015. Published D
12、ecember 2010July 2015. Originally approved in 2004. Last previous edition approved in 2010 asD7011 10.D7011 10a. DOI: 10.1520/D7011-10A.10.1520/D7011-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM St
13、andardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.This document is not an ASTM standard and i
14、s intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the
15、 current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 The method allows the
16、use of a sulfur chemiluminescence detector, atomic emission detector, pulsed flame photometricdetector, or any other sulfur selective detector provided that its performance meets requirements as set forth in 5.4. As sulfurcompounds elute from the gas chromatographic column, they are detected and qua
17、ntified. While the benzene molecule does notcontain any sulfur atoms, the possibility of matrix quenching and interference is a concern, especially for thiophene determinationat levels less than about 0.5 mg/kg. The column and conditions specified in Table 1 yield acceptable results with minimal mat
18、rixquenching and interference. Employing the column and conditions listed in Table 1 is not a requirement to meet the needs of allusers. For example, there is less concern of quenching and interference encountered with thiophene concentration levels greaterthan 0.5 mg/kg. Users of flame photometric
19、detectors should refer to Test Method D4735.4. Significance and Use4.1 Accurate gas chromatographic determination of trace levels of thiophene in benzene involves special analytical problemsbecause of the difficulties of trace level analysis. These problems arise from the low concentration levels th
20、at need to be measured,the type of column and detector needed for analysis, and the potential interference from the benzene matrix.4.2 This test method was found applicable for determining thiophene in refined benzene conforming to the specificationsdescribed in Specifications D2359, D4734, and D587
21、1 and may be applicable toward other grades of benzene if the user has takenthe necessary precautions as described in the text.4.3 This test method was developed as an alternative technique to Test MethodsMethod D1685 and D4735.5. Apparatus5.1 Gas ChromatographThe gas chromatograph shall be capable
22、of producing retention times for thiophene repeatable towithin 0.05 min. The gas chromatograph shall be equipped with an appropriate sulfur selective detector, column for separation,and sample inlet system for repeatable injection of sample volume.5.2 ColumnSpecifications and conditions described in
23、 Table 1 have been judged satisfactory for this analysis. The use of anycolumn that permits separation and determination of thiophene in benzene at levels consistent with the scope of this method isallowed. Specific chromatographic results and conditions are illustrated in Fig. 1. The user is referr
24、ed to Practice E1510 forinformation on installation of fused silica capillary columns.5.3 Sample Inlet SystemThe sample inlet system shall be able to quantitatively transfer the sample to the analytical column.It shall be capable of introducing constant and repeatable volumes of sample and calibrati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70112015RED4750STANDARDTESTMETHODFORDETERMINATIONOFTRACETHIOPHENEINREFINEDBENZENEBYGASCHROMATOGRAPHYANDSULFURSELECTIVEDETECTION

链接地址:http://www.mydoc123.com/p-524241.html