ASTM D7011-2010a 1875 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《通过气色谱法和硫磺选择探测测定精制苯中痕量噻吩的标准试验.pdf
《ASTM D7011-2010a 1875 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《通过气色谱法和硫磺选择探测测定精制苯中痕量噻吩的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM D7011-2010a 1875 Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection《通过气色谱法和硫磺选择探测测定精制苯中痕量噻吩的标准试验.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7011 10aStandard Test Method forDetermination of Trace Thiophene in Refined Benzene byGas Chromatography and Sulfur Selective Detection1This standard is issued under the fixed designation D7011; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of thiophenein refined benzene using g
3、as chromatography and sulfurselective detection. The test method is applicable to thedetermination of thiophene at levels of 0.02 to 2.18 mgthiophene per kg in benzene (mg/kg) on the AED, 0.03 to 1.87mg/kg on the PFPD, and 0.03 to 2.11 mg/kg on the SCD. Therange of the test method may be extended by
4、 modifying thesample injection volume, split ratios, calibration range, orsample dilution with thiophene-free solvent.1.2 In determining the conformance of the test results usingthis method to applicable specifications, results shall berounded off in accordance with the rounding-off method ofPractic
5、e E29.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis
6、h appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1685 Test Method for Traces of Thiophene in Benzene bySpec
7、trophotometry3D2359 Specification for Refined Benzene-535D3437 Practice for Sampling and Handling Liquid CyclicProductsD4734 Specification for Refined Benzene-545D4735 Test Method for Determination of Trace Thiophenein Refined Benzene by Gas ChromatographyD5871 Specification for Benzene for Cyclohex
8、ane Feed-stockD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE69
9、1 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120043. Summary of Test Method3.1 The th
10、iophene concentration in refined benzene is de-termined at the sub-mg/kg to low mg/kg level using conven-tional gas chromatography with a sulfur selective detector. Areproducible volume of sample is injected. Quantitative resultsare obtained by the use of the external standard calibrationtechnique.3
11、.2 The method allows the use of a sulfur chemilumines-cence detector, atomic emission detector, pulsed flame photo-metric detector, or any other sulfur selective detector providedthat its performance meets requirements as set forth in 5.4.Assulfur compounds elute from the gas chromatographic column,
12、they are detected and quantified. While the benzene moleculedoes not contain any sulfur atoms, the possibility of matrixquenching and interference is a concern, especially forthiophene determination at levels less than about 0.5 mg/kg.The column and conditions specified in Table 1 yield accept-able
13、results with minimal matrix quenching and interference.Employing the column and conditions listed in Table 1 is not a1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.04 on Instrumental
14、Analysis.Current edition approved Dec. 1, 2010. Published December 2010. Originallyapproved in 2004. Last previous edition approved in 2010 as D7011 - 10. DOI:10.1520/D7011-10A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
15、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capito
16、l St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.requirement to meet the needs of all users. For example, thereis less concern of quenching and interference enc
17、ountered withthiophene concentration levels greater than 0.5 mg/kg. Users offlame photometric detectors should refer to Test MethodD4735.4. Significance and Use4.1 Accurate gas chromatographic determination of tracelevels of thiophene in benzene involves special analyticalproblems because of the dif
18、ficulties of trace level analysis.These problems arise from the low concentration levels thatneed to be measured, the type of column and detector neededfor analysis, and the potential interference from the benzenematrix.4.2 This test method was found applicable for determiningthiophene in refined be
19、nzene conforming to the specificationsdescribed in Specifications D2359, D4734, and D5871 andmay be applicable toward other grades of benzene if the userhas taken the necessary precautions as described in the text.4.3 This test method was developed as an alternative tech-nique to Test Methods D1685
20、and D4735.5. Apparatus5.1 Gas ChromatographThe gas chromatograph shall becapable of producing retention times for thiophene repeatableto within 0.05 min. The gas chromatograph shall be equippedwith an appropriate sulfur selective detector, column forseparation, and sample inlet system for repeatable
21、 injection ofsample volume.5.2 ColumnSpecifications and conditions described inTable 1 have been judged satisfactory for this analysis. The useof any column that permits separation and determination ofthiophene in benzene at levels consistent with the scope of thismethod is allowed. Specific chromat
22、ographic results and con-ditions are illustrated in Fig. 1. The user is referred to PracticeE1510 for information on installation of fused silica capillarycolumns.5.3 Sample Inlet SystemThe sample inlet system shall beable to quantitatively transfer the sample to the analyticalcolumn. It shall be ca
23、pable of introducing constant andrepeatable volumes of sample and calibration standards. Use ofa liquid autosampler or liquid sampling valve is permitted forthe analysis of thiophene in benzene.5.4 DetectorA sulfur selective detector is used and shallmeet or exceed the following specifications: (1)
24、linearity orcompensated linearity of at least 102, (2) minimum detectablelevel of less than 0.02 mg/kg thiophene in benzene, (3)selectivity of sulfur to carbon greater than 105, and (4) absenceof quenching that affect results under the conditions used forthe analysis.5.5 Data Handling SystemUse of a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70112010A1875STANDARDTESTMETHODFORDETERMINATIONOFTRACETHIOPHENEINREFINEDBENZENEBYGASCHROMATOGRAPHYANDSULFURSELECTIVEDETECTION

链接地址:http://www.mydoc123.com/p-524240.html