1、Designation: D 6817 07Standard Specification forRigid Cellular Polystyrene Geofoam1This standard is issued under the fixed designation D 6817; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the types, physical propertiesand dimensions of rigid cellular polystyrene intended for use asgeofoam.1.2 This specific
3、ation does not cover the layout, placementand workmanship for proper installation and performance ofrigid cellular polystyrene geofoam.1.3 Rigid cellular polystyrene geofoam covered by thisspecification may need protection from certain chemicals,environmental exposure, and concentrated loads. Additi
4、onaldesign considerations may include thermal conductivity andbuoyancy. Guidelines regarding these end use considerationsare included in Appendix X1.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this s
5、tandard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2C 165 Test Method for Measuring Compressive Propertiesof Thermal InsulationsC 203 Test Methods for Breaking Load and Flexu
6、ral Prop-erties of Block-Type Thermal InsulationC 303 Test Method for Dimensions and Density of Pre-formed Block and BoardType Thermal InsulationC 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC 578 Specification for Rigid, Cellular PolystyreneThermalInsulationD 1621 Test Method
7、for Compressive Properties Of RigidCellular PlasticsD 1622 Test Method forApparent Density of Rigid CellularPlasticsD 2863 Test Method for Measuring the Minimum OxygenConcentration to Support Candle-Like Combustion ofPlastics (Oxygen Index)3. Terminology3.1 Definitions:3.1.1 Terms used in this speci
8、fication are defined in Termi-nology D 4439.3.1.2 geofoamblock or planar rigid cellular foam poly-meric material used in geotechnical engineering applications.3.2 Definitions of Terms Specific to This Standard:3.2.1 EPS, XXnumber designation for expanded polysty-rene geofoam Type(s) having a minimum
9、 density of XXkg/m3(lb/ft3).3.2.2 XPS, XXnumber designation for extruded polysty-rene geofoam Type(s) having a minimum density of XXkg/m3(lb/ft3).3.2.3 RCPSletter designation for EPS and XPS rigidcellular polystyrene geofoam covered by this specification.4. Ordering Information4.1 Acquisition docume
10、nts shall specify the following:4.1.1 Title, number and year of this specification.4.1.2 Type, as per Table 1, or minimum density required.4.1.3 Total product volume required of each Type, orminimum density.5. Materials and Manufacture5.1 RCPS geofoam shall be formed by the expansion ofpolystyrene r
11、esin beads or granules in a molding process (EPS)or by the expansion of polystyrene base resin in an extrusionprocess (XPS). RCPS geofoam may be manufactured withreprocessed polystyrene foam (regrind).5.2 RCPS geofoam shall be of uniform density and haveessentially closed cells. RCPS geofoam is an o
12、rganic materialand is considered combustible. It should not be exposed toflames or other ignition sources.1This specification is under the jurisdiction of ASTM Committee D35 onGeosynthetics and is the direct responsibility of Subcommittee D35.03 on Perme-ability and Filtration.Current edition approv
13、ed Dec. 1, 2007. Published December 2007. Originallyapproved in 2002. Last previous edition approved in 2006 as D 6817 06a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, re
14、fer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (all rights reserved); Wed Sep 10 20:31:08 EDT 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to
15、 License Agreement. No further reproductions authorized.TABLE1PhysicalPropertyRequirementsofRCPSGeofoamA,BTypeEPS12EPS15EPS19EPS22EPS29EPS39EPS46XPS20XPS21XPS26XPS29XPS36XPS48Density,min.,kg/m3(lb/ft3)11.2(0.70)14.4(0.90)18.4(1.15)21.6(1.35)28.8(1.80)38.4(2.40)45.7(2.85)19.2(1.20)20.8(1.30)25.6(1.60
16、)28.8(1.80)35.2(2.20)48.0(3.00)CompressiveResistance,min.,kPa(psi)at1%15(2.2)25(3.6)40(5.8)50(7.3)75(10.9)103(15.0)128(18.6)20(2.9)35(5.1)75(10.9)105(15.2)160(23.2)280(40.6)CompressiveResistance,min.,kPa(psi)at5%35(5.1)55(8.0)90(13.1)115(16.7)170(24.7)241(35.0)300(43.5)85(12.3)110(16.0)185(26.8)235(
17、34.1)335(48.6)535(77.6)CompressiveResistance,min.,kPa(psi)at10%A40(5.8)70(10.2)110(16.0)135(19.6)200(29.0)276(40.0)345(50)104(15.0)104(15.0)173(25.0)276(40.0)414(60.0)690(100.0)FlexuralStrength,min.,kPa(psi)69(10.0)172(25.0)207(30.0)276(40.0)345(50.0)414(60.0)517(75.0)276(40.0)276(40.0)345(50.0)414(
18、60.0)517(75.0)689(100.0)Oxygenindex,min.,volume%24.024.024.024.024.024.024.024.024.024.024.024.024.0AIfyieldoccurspriorto10%deformation,reportcompressiveresistanceanddeformationatyieldinadditiontothecompressiveresistanceat1%,5%and10%deformation.BForproductsthathaveanexternalskin,testingshallbeundert
19、akenwithskinsintact.D6817072Copyright by ASTM Intl (all rights reserved); Wed Sep 10 20:31:08 EDT 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further reproductions authorized.6. Qualification Requirements6.1 The physical properties listed in Table 1 constitute themini
20、mum product qualification requirements for commonlymanufactured types of RCPS geofoam.6.2 RCPS Geofoam TypesIt is the users responsibility tospecify the required Type as inTable 1 and to obtain supportingdocumentation regarding physical properties from the materialsupplier.6.3 Combustibility Require
21、mentsAll RCPS geofoam shallcontain sufficient flame retardants to meet a minimum OxygenIndex as required in Table 1.6.4 CuringUnless otherwise specified in the contract,RCPS geofoam shall be cured for a minimum of 24 h beforedelivery and inspection.7. Availability and Dimensional Tolerance7.1 Availa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD68172007895STANDARDSPECIFICATIONFORRIGIDCELLULARPOLYSTYRENEGEOFOAM 刚性 泡沫 聚苯乙烯 土工 材料 标准规范 PDF

链接地址:http://www.mydoc123.com/p-523665.html