ASTM D6749-2002(2012) 1250 Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method)《石油产品倾点的标准试验方法 (自动空气压力法)》.pdf
《ASTM D6749-2002(2012) 1250 Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method)《石油产品倾点的标准试验方法 (自动空气压力法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6749-2002(2012) 1250 Standard Test Method for Pour Point of Petroleum Products (Automatic Air Pressure Method)《石油产品倾点的标准试验方法 (自动空气压力法)》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6749 02 (Reapproved 2012)Standard Test Method forPour Point of Petroleum Products (Automatic Air PressureMethod)1This standard is issued under the fixed designation D6749; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers an alternative procedure for the determination of pour point of petroleumproduc
3、ts using an automatic apparatus.1. Scope1.1 This test method covers the determination of pour pointof petroleum products by an automatic apparatus that applies aslightly positive air pressure onto the specimen surface whilethe specimen is being cooled.1.2 This test method is designed to cover the ra
4、nge oftemperatures from 57 to +51C; however, the range oftemperatures included in the (1998) interlaboratory test pro-gram only covered the temperature range from 51 to 11C.1.3 Test results from this test method can be determined ateither 1 or 3C testing intervals.1.4 This test method is not intende
5、d for use with crude oils.NOTE 1The applicability of this test method on residual fuel sampleshas not been verified. For further information on the applicability, refer to13.4.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.
6、1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced D
7、ocuments2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum Products2.2 Energy Institute Standard:IP 15 Test Method for Pour Point of Petroleum Pro
8、ducts33. Terminology3.1 Definitions:3.1.1 pour point, nin petroleum products, lowest tempera-ture at which movement of the test specimen is observed underprescribed conditions of test.3.2 Definitions of Terms Specific to This Standard:3.2.1 air pressure, nregulated slightly positive air pres-sure ge
9、ntly applied onto the specimen surface in the airtighttest jar that causes upward movement of the specimen in thecommunicating tube, which has one end inserted into the testspecimen and the other end at atmospheric pressure.3.2.2 no-flow point, nin petroleum products, temperatureof the test specimen
10、 at which a wax crystal structure of the testspecimen or viscosity increase, or both, impedes movement ofthe surface of the test specimen under the conditions of the test.3.2.2.1 DiscussionThe no-flow point occurs when, uponcooling, the formation of wax crystal structures or viscosityincrease, or bo
11、th, has progressed to the point where the appliedobservation device no longer detects movement under theconditions of the test. The preceding observation temperature,at which flow of the test specimen is last observed, is the pourpoint.4. Summary of Test Method4.1 After inserting the test jar contai
12、ning the specimen intothe automatic pour point apparatus and initiating the test1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved Nov. 1, 2012. Publi
13、shed November 2012. Originallyapproved in 2002. Last previous edition approved in 2007 as D674902 (2007).DOI: 10.1520/D6749-02R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informat
14、ion, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1program, th
15、e specimen is automatically heated to the desig-nated temperature and then cooled at a controlled rate. Attemperature intervals of 1 or 3C, depending on the selectionmade by the user prior to the test, a slightly positive airpressure is gently applied onto the surface of the specimenwhich is contain
16、ed in an airtight test jar equipped with acommunicating tube. Since one end of the communicating tubeis inserted into the specimen while the other end is maintainedat atmospheric pressure, a small amount of downward move-ment or deformation of the specimen surface, as a result of theapplication of a
17、ir pressure, is observed by means of upwardmovement of the specimen in the communicating tube. Thisupward movement of the specimen is detected by a pressuresensor which is installed at the atmospheric end of thecommunicating tube. The lowest temperature at which defor-mation of the specimen is obser
18、ved upon application of airpressure is recorded as the pour point in accordance with TestMethod D6749.5. Significance and Use5.1 The pour point of a petroleum product is an index of thelowest temperature of its utility for certain applications. Flowcharacteristics, like pour point, can be critical f
19、or the correctoperation of lubricating systems, fuel systems, and pipelineoperations.5.2 Petroleum blending operations require precise measure-ment of the pour point.5.3 Test results from this test method can be determined ateither 1 or 3C intervals.5.4 This test method yields a pour point in a form
20、at similarto Test Method D97/IP 15 when the 3C interval results arereported. However, when specification requires Test MethodD97/IP 15, do not substitute this test method.NOTE 2Since some users may wish to report their results in a formatsimilar to Test Method D97/IP 15 (in 3C intervals), the precis
21、ion datawere derived for the 3C intervals. For statements on bias relative to TestMethod D97/IP 15, see 13.3.1.5.5 This test method has better repeatability and reproduc-ibility relative to Test Method D97/IP 15 as measured in the1998 interlaboratory test program (see Section 13).6. Apparatus6.1 Aut
22、omatic Apparatus4,5The automatic pour point ap-paratus described in this test method is a microprocessorcontrolled apparatus that is capable of heating and cooling aspecimen, applying air pressure onto the specimens surface,detecting the specimens surface movement, and then comput-ing and reporting
23、the pour point (see Fig. 1). The detail isdescribed in Annex A1.6.2 Test Jar, clear cylindrical glass with a flat bottom withan approximate capacity of 12 mL. Approximately 4.5 mL ofsample specimen is contained when filled to the scribed line.The test jar is fitted with a test jar cap assembly on it
24、s top toform an air chamber over the test specimen.6.3 Test Jar Cap AssemblyAplastic cap is installed on topof the test jar with the provision of sealing air.Aglass tube witha metallic tip shall be inserted from underneath the plastic capinto the round hole in the center of the test jar cap. The top
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6749200220121250STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTSAUTOMATICAIRPRESSUREMETHOD 石油 产品

链接地址:http://www.mydoc123.com/p-523429.html