《ASTM D6705-2004 Standard Guide for the Repair and Recoat of Sprayed Polyurethane Foam Roofing Systems《喷涂的聚氨基甲酸乙酯泡沫屋面系统的修理和再涂的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6705-2004 Standard Guide for the Repair and Recoat of Sprayed Polyurethane Foam Roofing Systems《喷涂的聚氨基甲酸乙酯泡沫屋面系统的修理和再涂的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6705 04Standard Guide forRepair and Recoat of Spray Polyurethane Foam RoofingSystems1This standard is issued under the fixed designation D 6705; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the procedures for the repair andrecoating of existing spray polyurethane roofing systems.1.2 The values state
3、d in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and heal
4、th practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 1029 Specification for Spray-Applied Rigid CellularPolyurethane Thermal InsulationD 5469 Guide for Application of New Spray Applied Poly-urethane Foam and Coated Roofing
5、SystemsD 6083 Specification for Liquid Applied Acrylic CoatingUsed In Roofing2.2 SPFA Standards:3AY 102 A Guide for Selection of Elastomeric ProtectiveCoatings Over Sprayed Polyurethane FoamAY 107 Spray Polyurethane Foam Blisters, Their Causes,Types, Prevention and Repair2.3 API Standard:4Alliance f
6、or The Polyurethane Industry (API), Bulletin AX119 Guide for Safe Handling and Use of Polyurethaneand Polyisocyanurate Foam Systems3. Terminology3.1 Definitions:3.1.1 recoatto apply a new protective coating over anexisting coated SPF (spray polyurethane foam) roof system toextend the performance lif
7、e of the roofing system.3.1.2 scarfingto shave or grind an SPF foam surfacemechanically to remove a coating, or UV deteriorated SPF, orboth, to refoam or recoat the surface.4. Significance and Use4.1 This guide outlines general procedures and precautionsnecessary for correct and safe repair and reco
8、at of SPF roofingsystems.4.2 This guide is not all inclusive; this guide is intended tosupplement detailed instructions from manufacturers andsafety requirements required by law.5. Roof Inspection Procedures and Considerations5.1 General Considerations:5.1.1 The performance of a sprayed-in-place pol
9、yurethanefoam roof system can be affected by all the component parts ofthe roof structure, as well as the atmospheric conditions insideand outside the structure. Structural design, code compliance,specification review, contractor, and material selection shouldbe considered in the repair and recoat o
10、f a spray polyurethanefoam roof system.5.1.2 A range of spray polyurethane foam systems existswith various physical properties, exhibiting different tempera-ture limitations, and different combustibility characteristics.Most published data are obtained from testing of laboratorysamples. The thicknes
11、s of the polyurethane foam sprayed,number of passes, temperature of substrate, ambient tempera-ture, and so forth will have an effect on all polyurethane foamproperties.5.1.3 The specifier should consult with the respective ma-terial manufacturer of the sprayed-in-place polyurethane foamroof system.
12、 This should include, but not be limited to,materials selection, expansion joints, flashing details, and otheritems.1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.06 on SprayPolyurethane Foam Roof Systems.C
13、urrent edition approved Dec. 1, 2004. Published December 2004. Originallyapproved in 2001. Last previous edition approved in 2001 as D 6705 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
14、lume information, refer to the standards Document Summary page onthe ASTM website.3Available from Spray Polyurethane Foam Alliance, 4400 Fair Lakes Ct., Suite105, Fairfax, VA 22033.4Available from TheAlliance for the Polyurethanes Industry, 1300 Wilson Blvd.,Arlington, VA 22209.1Copyright ASTM Inter
15、national, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Inspection:5.2.1 The preparation for the repair and recoat of a sprayed-in-place polyurethane foam roof system will vary according tothe conditions of the roof and its component parts and the typeof exi
16、sting protective coating used over the polyurethane foam.5.2.2 Conduct a roof inspection to determine the repairs tobe performed and the type of materials to be used.5.3 Visual Inspection:5.3.1 Look for blisters or delaminated areas in the originalroof.5.3.2 Check the condition of the roofing system
17、 at allflashing and termination points.5.3.3 Look for damage that would affect recoating of theroofing system.5.3.4 Check for pinholes in the polyurethane foam, orcoating, or both.5.3.5 Check for exposed polyurethane foam and areas oferoded coating.5.3.6 Check for areas of ponding water.5.4 Physical
18、 Inspection:5.4.1 Perform a nondestructive moisture survey. Follow upsuspected moisture-laden areas with a moisture probe or coresamples.5.4.2 Take slit samples of the existing system as required bythe new coating manufacturer.5.4.3 Take polyurethane foam core samples as required bythe SPF, or coati
19、ng manufacturer, or both.5.5 Analyze Inspection:5.5.1 Core and slit samples should be examined for thefollowing characteristics:5.5.1.1 Adhesion of polyurethane foam to the substrate,5.5.1.2 Interlaminar adhesion of polyurethane foam,5.5.1.3 Presence of moisture,5.5.1.4 Adhesion of base coat to poly
20、urethane foam,5.5.1.5 Adhesion of top coat to base coat,5.5.1.6 Type and condition of protective coating, and5.5.1.7 Thickness of protective coating.5.5.2 On a roof sketch, indicate the following items anddeficiencies:5.5.2.1 Location of core and slit samples,5.5.2.2 Areas of pinholes,5.5.2.3 Uncure
21、d coating,5.5.2.4 Polyurethane foam or coating blisters,5.5.2.5 Mechanical damage,5.5.2.6 Poor drainage,5.5.2.7 Repairs required for foamstops, parapet walls, gut-ters, scuppers, edge-termination details, expansion joints,counterflashing, and other perimeter items,5.5.2.8 Repairs required to soil an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD67052004STANDARDGUIDEFORTHEREPAIRANDRECOATOFSPRAYEDPOLYURETHANEFOAMROOFINGSYSTEMS 喷涂 氨基 甲酸 泡沫 屋面

链接地址:http://www.mydoc123.com/p-523290.html