ASTM D6383 D6383M-1999(2011)e1 7500 Standard Practice for Time-to-Failure (Creep-Rupture) of Adhesive Joints Fabricated from EPDM Roof Membrane Material《由EPDM屋顶膜材料制造的胶粘剂接头的失效时间(蠕变破.pdf
《ASTM D6383 D6383M-1999(2011)e1 7500 Standard Practice for Time-to-Failure (Creep-Rupture) of Adhesive Joints Fabricated from EPDM Roof Membrane Material《由EPDM屋顶膜材料制造的胶粘剂接头的失效时间(蠕变破.pdf》由会员分享,可在线阅读,更多相关《ASTM D6383 D6383M-1999(2011)e1 7500 Standard Practice for Time-to-Failure (Creep-Rupture) of Adhesive Joints Fabricated from EPDM Roof Membrane Material《由EPDM屋顶膜材料制造的胶粘剂接头的失效时间(蠕变破.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6383/D6383M 99 (Reapproved 2011)1Standard Practice forTime-to-Failure (Creep-Rupture) of Adhesive JointsFabricated from EPDM Roof Membrane Material1This standard is issued under the fixed designation D6383/D6383M; the number immediately following the designation indicates theyear of or
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially revised in June 2011.1. Scope1.1 T
3、his practice covers sample preparation temperatures,test parameters, and specimen exposure conditions that areapplicable when Test Method D5405 is used for conductingtime-to-failure (creep-rupture) tests of adhesive joints fabri-cated from ethylene-propylene-diene terpolymer (EPDM) roofmembrane mate
4、rial.1.2 This practice is applicable to joints fabricated in thelaboratory from EPDM roof membrane materials and adhe-sives received from suppliers, and to joints prepared fromEPDM seams sampled from field installations.1.3 The joints are bonded using preformed tape or liquid-based adhesives, and EP
5、DM roof membrane materials that arenon-reinforced, fabric- or scrim-reinforced, and fabric backed.Primers are also used as recommended for the specific adhe-sive.1.4 This practice contains notes that are explanatory and arenot part of the mandatory requirements of this practice.1.5 The values stated
6、 in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.6 This
7、 standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of the regulatory limitations prior to use.2. Referenced Docum
8、ents2.1 ASTM Standards:2D907 Terminology of AdhesivesD1079 Terminology Relating to Roofing and WaterproofingD5405 Test Method for Conducting Time-to-Failure(Creep-Rupture) Tests of Joints Fabricated from Nonbitu-minous Organic Roof Membrane Material2.2 SPRI Document:3SPRI Recommended Laboratory Test
9、 Methods for Liquidand TapeAdhesives Used to Splice Single-Ply Membranes3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminologies D907 and D1079.3.2 Definitions of Terms Specific to This Standard:3.2.1 creep-rupture testa test that measures the time-to-fail
10、ure of a specimen subjected to a constant load; progressivespecimen deformation may also be measured.3.2.2 failurerupture of the bond resulting in completeseparation of its adherents under the test conditions; or,alternatively, rupture of the membrane material away from thebonded section of the test
11、 specimen (that is, material rupture).3.2.3 time-to-failurethe period of time beginning when ajoint specimen is placed under load and ending when failureoccurs.4. Summary of Practice4.1 Adhesive joints are prepared in the laboratory at ambi-ent and low temperatures using tape or liquid adhesives and
12、1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.18 on Nonbi-tuminous Organic Roof Coverings.Current edition approved May 1, 2011. Published June 2011. Originallyapproved in 1999. Last previous edition appr
13、oved in 2005 as D6383 99 (2005).DOI: 10.1520/D6383_D6383M-99R11E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM we
14、bsite.3Available from Single Ply Roofing Institute (SPRI), 77 RumfordAve., Suite 3B,Waltham, MA 02453.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.EPDM roof membrane material. Creep-rupture tests are thenconducted in accordance wi
15、th Test Method D5405 before andafter subjecting these joints to artificial exposure in thelaboratory. The loads are applied in either peel or shearconfigurations at ambient and elevated temperatures. Table 1summarizes the preparation temperatures, test parameters, andexposure conditions incorporated
16、 in this practice.Alternatively,adhesive joints are prepared from EPDM seams sampled fromroofs in service, and then subjected directly to creep-rupturetesting.5. Significance and Use5.1 An important factor affecting the performance of seamsof EPDM membranes is their ability to remain bonded over the
17、membranes expected service life. Time-to-failure tests providea means of characterizing the behavior of joints under constantload over time.NOTE 1Table 1 is based on the results of an industry governmentconsortium study on creep-rupture resistance (time-to-failure) of EPDMadhesive joints.4,5Referral
18、 to Footnotes 5 and 6 provides typical time-to-failure data, developed under the conditions in Table 1, for EPDM jointsfabricated in the laboratory with nonreinforced EPDM roof membranematerial, butyl-based tapes, and liquid adhesives. It is noted that the peelload specified in this practice is 9.8
19、N 2.2 lbf. The peel load under whichthe tests described in Footnotes 4 and 5 were conducted was 9.3 N 2.1lbf. A load of 9.8 N 2.2 lbf corresponds to 1 kgf 2.2 lbf, and deadweights of 1-kg 2.2-lbm mass are available through laboratory equip-ment supply houses. Similarly, a load of 29.4 N 6.6 lbf corr
20、esponds to adead weight of 3-kg 6.6-lbm mass.5.2 Time-to-failure tests complement other mechanical testssuch as strength for characterizing joints of EPDM roofmembranes, and can be incorporated in specifications foradhesives for joining EPDM roof membrane material.5.3 This practice, which is specifi
21、c to EPDM joints, comple-ments Test Method D5405 that provides general requirementsfor the preparation and creep-rupture testing of joints fabri-cated from any nonbituminous organic roof membrane mate-rial.5.4 Laboratory experience in conducting time-to-failuretests of joints EPDM roof membranes has
22、 shown that speci-mens are less creep-resistant under peel loading than undershear loading. Consequently, the majority of the tests stipulatedin this practice are performed under peel loading.5.5 This practice does not develop time-to-failure data on allenvironmental conditions to which EPDM adhesiv
23、e seams canbe subjected in service.6. Test Specimen6.1 Laboratory SpecimensPrepare peel specimens andshear specimens as described in Section 8 of Test MethodD5405. Table 1 lists the seven sample sets for which specimensare prepared.6.1.1 Peel Specimen DimensionsThe dimensions of thepeel specimens sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6383D6383M19992011E17500STANDARDPRACTICEFORTIMETOFAILURECREEPRUPTUREOFADHESIVEJOINTSFABRICATEDFROMEPDMROOFMEMBRANEMATERIAL

链接地址:http://www.mydoc123.com/p-522354.html