ASTM D1780-2005(2012) Standard Practice for Conducting Creep Tests of Metal-to-Metal Adhesives《金属间胶粘剂蠕变试验的标准实施规程》.pdf
《ASTM D1780-2005(2012) Standard Practice for Conducting Creep Tests of Metal-to-Metal Adhesives《金属间胶粘剂蠕变试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1780-2005(2012) Standard Practice for Conducting Creep Tests of Metal-to-Metal Adhesives《金属间胶粘剂蠕变试验的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1780 05 (Reapproved 2012)Standard Practice forConducting Creep Tests of Metal-to-Metal Adhesives1This standard is issued under the fixed designation D1780; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice covers the determination
3、 of the amount ofcreep of metal-to-metal adhesive bonds due to the combinedeffects of temperature, tensile shear stress, and time.NOTE 1Since the characteristics that render a material resistant tocreep under the condition of test are not yet completely known, the detailsof the procedure considered
4、herein are those known to have importantinfluences. Since other equally important characteristics may be discov-ered in the future, the recommended details are largely advisory in nature.1.2 Test periods depend upon the reasonable life expectedfrom the material in service. The uncertainties of extra
5、polationshould be considered in deciding upon the length of the test.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
6、It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D907 Terminology of AdhesivesD1002 Test Method for Apparent Shear Strength of
7、Single-Lap-Joint Adhesively Bonded Metal Specimens by Ten-sion Loading (Metal-to-Metal)3. Terminology3.1 DefinitionsMany of the terms in this practice aredefined in Terminology D907.3.2 Definitions of Terms Specific to This Standard:3.2.1 creep, nthe time-dependent part of the strain thatresults fro
8、m exposure to a constant temperature and load (Note2). That is, the creep at a given elapsed time is equal to the totalstrain at the given time minus the instantaneous strain (Note 3)on loading. The creep extension is expressed as a percentage,that is, the extension divided by the initial unstretche
9、d lengthmultiplied by 100.NOTE 2Constant-stress creep tests are desirable. The usual one is aconstant deadweight load test. Creep tests made by means of springloading or fixtures which involve deflection or strain measurements in thefixture for the application of load are unsatisfactory. However, if
10、 the totaldeformation or extension in the adhesive is large, corrections must bemade to compensate for the decrease in stress because of the extension inthe adhesive.NOTE 3Since the time-dependent strain develops rapidly even duringthe application of the load, the instantaneous strain for recovery i
11、s usuallydifficult to determine, except in the arbitrary manner given in thedefinitions of instantaneous strain and instantaneous recovery.3.2.2 deformation, nthe total strain at any specific time.3.2.3 failure, nrupture of the specimen, or exceeding thestrain requirements of a specific design.3.2.4
12、 instantaneous recovery, nthe decrease in strain oc-curring immediately upon unloading a specimen. As in instan-taneous strain, a more reproducible value is obtained if thedecrease in strain is measured after a given small increment oftime (such as 1 min) following unloading. The increment oftime us
13、ed shall be specified. The instantaneous recovery shallbe expressed in the same units as strain, that is, the decrease inlength divided by the gage length usually, in inches per inch.3.2.5 instantaneous strain, nthe strain occurring immedi-ately upon loading a creep specimen. Since it is nearlyimpos
14、sible to obtain strain readings at the instant of loading,the strain after a given small increment of time (such as 1 min)after loading is a more reproducible value. The increment oftime used shall be specified. The instantaneous strain shall beexpressed in the units as strain, that is, the extensio
15、n divided bythe gage length, usually in inches per inch.3.2.6 recovery, nthe time-dependent portion of the de-crease in strain following unloading of a specimen at the sameconstant temperature as the initial test. Recovery is equal to thetotal decrease in strain minus the instantaneous recovery (see
16、Note 3). The recovery shall be expressed in the same units asinstantaneous recovery.1This practice is under the jurisdiction of ASTM Committee D14 on Adhesivesand is the direct responsibility of Subcommittee D14.80 on Metal BondingAdhesives.Current edition approved Oct. 1, 2012. Published October 20
17、12. Originallyapproved in 1960. Last previous edition approved in 2005 as D1780 05. DOI:10.1520/D1780-05R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stan
18、dards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Significance and Use4.1 This practice provides information on the creep ofbonded metal parts subjected to combined effects oftemperature
19、, shear, and time.5. Possibilities and Limitations5.1 The primary use of creep tests is to provide basic datafor the choice of safe working stresses for applications inwhich allowable deformation within the service life of thestructure is the criterion of failure.5.2 Creep is an extremely sensitive
20、index of strength, andusually does not vary as a linear function of stress. (It dependson the material, stress, temperature, and time.)5.3 In the application of the following test requirements andrecommendations it is assumed that the test specimens of agiven adhesive bond are essentially comparable
21、 and trulyrepresentative of the material. In tests conducted to show theeffects of temperature or stress as variables, great care must beused to ensure that the specimens are representative of theadhesive bond. Departure from this assumption may introducediscrepancies as great as, if not greater tha
22、n, those due todeparture from details of procedure outlined in this practice.6. Apparatus6.1 Testing Machine, capable of producing a tensile load onthe specimen at the rate indicated in 10.2 and consisting of thefollowing:6.1.1 Fixed MemberA fixed or essentially stationarymember, carrying one grip.6
23、.1.2 Movable MemberA movable member, carrying asecond grip.6.1.3 GripsThe grips, designed to minimize eccentricloading of the specimen. A swivel or universal joint near eachend of the specimen is desirable wherever possible.6.2 MicroscopeA calibrated microscope having a Filarmicrometer eyepiece and
24、a 10 objective lens.7. Temperature Control and Measurement7.1 For tests at a particular temperature, maintain thespecimen at a constant temperature, preferably by a suitableautomatic control device. Where a furnace or cold box is used,it is desirable to locate this unit in a constant-temperature roo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD178020052012STANDARDPRACTICEFORCONDUCTINGCREEPTESTSOFMETALTOMETALADHESIVES 金属 胶粘剂 试验 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-510454.html