ASTM D6089-2015 red 5306 Standard Guide for Documenting a Groundwater Sampling Event《地下水取样事件文件形成标准指南》.pdf
《ASTM D6089-2015 red 5306 Standard Guide for Documenting a Groundwater Sampling Event《地下水取样事件文件形成标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6089-2015 red 5306 Standard Guide for Documenting a Groundwater Sampling Event《地下水取样事件文件形成标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6089 97 (Reapproved 2010)D6089 15Standard Guide forDocumenting a Groundwater Sampling Event1This standard is issued under the fixed designation D6089; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This guide covers what and how information should be recorded in the field when sampling a groundwater monitoring wel
3、l.Following these recommendations will provide adequate documentation in most monitoring programs. In some situations, it maybe necessary to record additional or different information, or both, to thoroughly document the sampling event. In other cases, itmay not be necessary to record all of the inf
4、ormation recommended in this guide. The level of documentation will be based onsite-specific conditions and regulatory requirements.1.2 This guide is limited to written documentation of a groundwater sampling event. Other methods of documentation (that is,electronic and audiovisual) can be used but
5、are not addressed in this guide. The specific activities addressed in this guide includedocumentation of static water level measurement, monitoring well purging, monitoring well sampling, field measurements,groundwater sample preparation, and groundwater sample shipment.1.3 This standard does not pu
6、rport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This guide offers an organized collection
7、of information or a series of options and does not recommend a specific courseof action. This document cannot replace education or experience and should be used in conjunction with professional judgment.Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not i
8、ntended to represent or replacethe standard of care by which the adequacy of a given professional service must be judged, nor should this document be appliedwithout consideration of a projects many unique aspects. The word “Standard” in the title of this document means only that thedocument has been
9、 approved through the ASTM consensus process.2. Referenced Documents2.1 ASTM Standards:2D4750 Test Method for Determining Subsurface Liquid Levels in a Borehole or Monitoring Well (Observation Well)(Withdrawn 2010)3D5088 Practice for Decontamination of Field Equipment Used at Waste SitesD5608 Practi
10、ces for Decontamination of Field Equipment Used at Low Level Radioactive Waste SitesD5903 Guide for Planning and Preparing for a Groundwater Sampling Event2.2 Government Document:40 CFR 261.4 (d) (ii)43. Terminology3.1 DefinitionsFor definitions of terms used in this guide, refer to Terminology D653
11、.3.2 Definitions of Terms Specific to This Standard:3.2.1 chain of custodythe process of maintaining accountability of the samples for the purpose of identifying potentialbreaches in sample integrity.3.2.2 chain of custody recorda record of all individuals who possess the samples from the time of co
12、llection until analysis.1 This guide is under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.21 on Groundwater and VadoseZone Investigations.Current edition approved July 1, 2010March 1, 2015. Published September 2010March 2015. Originall
13、y approved in 1997. Last previous edition approved in 20032010as D6089 97 (2003).(2010). DOI: 10.1520/D6089-97R10.10.1520/D6089-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume informat
14、ion, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depic
15、t all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internationa
16、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Significance and Use4.1 When sampling groundwater monitoring wells, it is very important to thoroughly document all field activities. Sufficientfield data should be retained to allow one to reconstruct the proc
17、edures and conditions that may have affected the integrity of asample. The field data generated are vital to the interpretation of the chemical data obtained from laboratory analyses of samples.Field data and observations may also be useful to analytical laboratory personnel.4.2 Due to the changing
18、nature of regulations and other information, users are advised to thoroughly research requirementsrelated to packaging and shipping prior to initiating a sampling event.NOTE 1The sampling of an individual groundwater monitoring well should be repeated as closely as possible each time the monitoring
19、well issampled. This reduces the variability of the chemical parameters due to sampling variability which is the desired result. The intent is to detect the changein chemistry by repeating the sampling protocol at each individual well. This does not mean that all the wells are sampled the same way,
20、nor does itprohibit changes in the sampling protocol, provided they are planned and documented.5. Documentation Methods5.1 Field records should be generated by a member of the sampling team. It is important to record procedures used andmeasurements immediately after they have been accomplished and a
21、re fresh in the memory. In general, notes should not be takenafter returning from the field.5.2 The format of the documentation is discretionary, but should be consistent from well to well and in accordance withregulatory requirements. Forms are often used for consistency and to reduce the chance of
22、 failing to record needed information.It may be desirable for records to be entered with indelible ink in a hard cover, stitch-bound book for credibility in litigation.6. Documentation Content6.1 General:6.1.1 Record the facility or site name, or both, and the well identification.6.1.2 Record the we
23、ather conditions.6.1.3 Record the names of all sampling team members.6.1.4 Record any instrument calibration details to include instrument identification and date and time of last calibration.6.1.5 Note any changes in the physical condition of the well.6.1.6 Note changes in land use or physical cond
24、itions of the site.6.1.7 Record wellhead observations and measurements (for example, odor, organic vapor measurements).6.1.8 Record any quality control samples collected or prepared in the field.6.1.9 Describe decontamination procedures for non-dedicated equipment (See Practice D5088, D5903 and D560
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60892015RED5306STANDARDGUIDEFORDOCUMENTINGAGROUNDWATERSAMPLINGEVENT 地下水 取样 事件 文件 形成 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-521505.html