1、Designation: D 6072 08Standard Practice forObtaining Samples of Geosynthetic Clay Liners1This standard is issued under the fixed designation D 6072; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for sampling geosyn-thetic clay liners (GCLs) for the purpose of laboratory testing.These procedures are des
3、igned to ensure that representativesamples are obtained and properly packaged for submittal to atesting laboratory.1.2 The procedures in this practice may be applied to eithersamples of unhydrated GCLs obtained at the project site priorto installation (or at the production facility, prior to shipmen
4、t tothe project site) or samples exhumed from a project site afterinstallation.1.3 It is assumed that the number of samples to be obtainedhas already been determined in the project specification,standard test method, or by prior agreement between thepurchaser and seller. This practice covers only th
5、e methods forobtaining a pre-arranged number of samples and does notdescribe methods for obtaining individual specimens from thesample.1.4 The values stated in SI units are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with
6、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 4220 Practices for Preserving and Transporting SoilSamplesD 4354 Pr
7、actice for Sampling of Geosynthetics for TestingD 4439 Terminology for GeosyntheticsD 5888 Guide for Storage and Handling of GeosyntheticClay Liners3. Terminology3.1 Definitions:3.1.1 geosynthetic clay liner (GCL), na manufacturedhydraulic barrier consisting of clay bonded to a layer or layersof geo
8、synthetics.3.1.2 sample, na portion of a material which is taken fortesting or for record purposes (See Practice D 4354).3.1.3 specimen, na specific portion of a material orlaboratory sample upon which a test is performed or which istaken for that purpose (See Practice D 4354).3.1.4 For definitions
9、of other geosynthetic terms used in thispractice, refer to Terminology D 4439.4. Significance and Use4.1 This practice provides a procedure by which samples ofGCL should be obtained for laboratory testing. The practiceapplies to materials obtained prior to installation (either at a jobsite or at a p
10、roduction facility) or exhumed material afterinstallation.4.2 Only GCL samples obtained in accordance with 5.1 ofthis practice will be considered representative of the actualmanufactured GCL for quality assurance/quality control (QA/QC) purposes4.3 The quantity of GCL received by the laboratory shou
11、ldbe sufficient for the preparation of several representative testspecimens for the standardized physical, hydraulic, and me-chanical tests to be performed on the GCLs.4.4 The procedures in this practice should be used by plantand field personnel for obtaining GCL samples for laboratorytesting.5. Pr
12、ocedure5.1 Obtaining Samples prior to Installation:5.1.1 In accordance with the project specifications or withPractice D 4354, divide the shipment or other given quantity ofGCL into lots, and select lot and laboratory samples. This willusually involve the selection of a certain number of finishedGCL
13、 rolls from which samples will be cut.1This practice is under the jurisdiction of ASTM CommitteeD35 on Geosyn-thetics and is the direct responsibility of Subcommittee D35.04 on GeosyntheticClay Liners.Current edition approved July 1, 2008. Published September 2008. Originallyapproved in 1996. Last p
14、revious edition approved in 2002 as D 607296(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright
15、 ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.2 Affix on the packaging of the GCL rolls to be sampledadhesive labels or other markings which clearly identify thatthe roll is to be sampled.5.1.3 Record the label information from each roll
16、 to besampled for future incorporation into within the qualityassurance/quality control (QA/QC) documentation for theGCL.5.1.4 Segregate the rolls identified for sampling. Refer toGuide D 5888 for the proper equipment and techniques forhandling the GCL rolls.5.1.5 Inspect the packaging of the select
17、ed GCL rolls fordamage. Describe and record the damage, if any.5.1.6 Remove the outer packaging from the GCL as care-fully as possible, taking precautions not to damage the GCLand to preserve the packaging as much as possible for re-useafter sampling is completed.5.1.7 Obtain samples from the select
18、ed GCL rolls. Thesurface on which the GCL is cut shall be smooth, hard, and freeof irregularities and potential contaminants. All samples shallbe obtained by cutting across the full width of the roll end,perpendicular to the edges. Samples shall be cut with a sharputility knife or other implement ca
19、pable of making a clean,straight cut through all components of the GCL. Unlessotherwise specified, the cut shall be made at a point that is 1.0m from the exposed end of the roll.NOTE 1At the discretion of the engineer, shorter or narrower samples,or both, may be obtained provided that the packaging
20、procedures in thisguide are followed.5.1.8 A unique sample number shall be written on thesample. Additional markings should be made on the sample toidentify the machine direction and the top/bottom sides of theGCL.5.1.9 The GCL sample shall then be manually rolled arounda core at least 75 mm in diam
21、eter, in the same direction as thecut. Care should be taken to wind the GCL without slack. Widestrapping tape (50 mm) shall then be wound around the samplein at least two places to secure the loose end. Bentonite lossfrom the sample may be minimized by applying the tapearound the roll ends.5.1.10 At
22、 least two layers of plastic sheeting shall be used towrap the GCL sample roll for shipment to the laboratory, so asto minimize GCL sample disturbance or changes in moisturecontent. A thin cellophane material may be used for the innerwrapping, provided it is wound securely and repeatedly aroundthe r
23、olled sample. The outer sheeting shall be at least 0.15 mm(6 mils) in thickness and shall be wrapped to minimize theamount of GCL shifting within the wrapping.5.1.11 To ensure proper sample chain-of-custody tracking,all shipping documents shall indicate the sample number,project name and contact, an
24、d laboratory name and contact.5.1.12 If an additional sample from the same GCL roll isrequired for testing, 5.1.6 through 5.1.10 of this practice maybe repeated on the exposed end of the roll until a sufficientamount of GCL is obtained.NOTE 2Additional material cut from the same roll is still consid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60722008809STANDARDPRACTICEFOROBTAININGSAMPLESOFGEOSYNTHETICCLAYLINERSPDF

链接地址:http://www.mydoc123.com/p-521449.html