ASTM D5987-1996(2015) 1742 Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Extraction and Ion Selective Electrode or Ion Chromatograph Methods《使用水解萃取和离子选.pdf
《ASTM D5987-1996(2015) 1742 Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Extraction and Ion Selective Electrode or Ion Chromatograph Methods《使用水解萃取和离子选.pdf》由会员分享,可在线阅读,更多相关《ASTM D5987-1996(2015) 1742 Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Extraction and Ion Selective Electrode or Ion Chromatograph Methods《使用水解萃取和离子选.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5987 96 (Reapproved 2015)Standard Test Method forTotal Fluorine in Coal and Coke by PyrohydrolyticExtraction and Ion Selective Electrode or IonChromatograph Methods1This standard is issued under the fixed designation D5987; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the analysis of total fluor
3、ine incoal and coke.1.2 This analysis was successfully tested on coals contain-ing 37 % ash or less (see AS 1038.10.4 and Conrad2).1.3 The values stated in SI units shall be regarded asstandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all
4、 of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements see Note 4.1.5 All accountability
5、 and quality control aspects of GuideD4621 apply to this test method.2. Referenced Documents2.1 ASTM Standards:3D346 Practice for Collection and Preparation of CokeSamples for Laboratory AnalysisD1193 Specification for Reagent WaterD2013 Practice for Preparing Coal Samples for AnalysisD2234/D2234M P
6、ractice for Collection of a Gross Sampleof CoalD3174 Test Method for Ash in the Analysis Sample of Coaland Coke from CoalD3180 Practice for Calculating Coal and Coke Analysesfrom As-Determined to Different BasesD4621 Guide for Quality Management in an OrganizationThat Samples or Tests Coal and Coke
7、(Withdrawn 2010)4D5142 Test Methods for Proximate Analysis of the AnalysisSample of Coal and Coke by Instrumental Procedures(Withdrawn 2010)42.2 Australian Standard:5AS 1038.10.4 Determination of Trace ElementsCoal,Coke and Fly-Ash-Determination of Fluorine ContentPyrohydrolysis Method3. Summary of
8、Test Method3.1 Total fluorine is determined in this test method by firstsubjecting the weighed test portion to pyrohydrolytic condi-tions which separate fluorine from the coal/coke matrix. Thepyrohydrolysate is then gravimetrically processed and finaldeterminations are made by either ion-selective e
9、lectrode orion chromatographic techniques.4. Significance and Use4.1 This test method permits measurement of the fluorinecontent of coal and coke for the evaluation of potential fluorineemission from coal combustion or conversion processes. Whencoal samples are combusted in accordance with this test
10、method, the fluorine is quantitatively released from the coaland retained in the pyrohydrolysate so that it is representativeof the total fluorine concentration in coal.5. Apparatus5.1 Laboratory WareExcept as noted, all laboratory ware,for example, volumetric flasks, beakers, bottles, etc., used fo
11、rsolutions containing fluoride ions must be made ofpolyethylene, polystyrene, or a heat-resistant polymer such aspolypropylene.5.2 VialsGlass or polystyrene, 10 to 30-mL capacity withtightly fitting snap-on plastic lids.1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Cok
12、e and is the direct responsibility of Subcommittee D05.29 on MajorElements in Ash and Trace Elements of Coal.Current edition approved Nov. 1, 2015. Published December 2015. Originallypublished approved in 1996. Last previous edition approved in 2007 asD598796(2007). DOI: 10.1520/D5987-96R15.2Conrad,
13、 V. B., and Brownlee, W. D., “HydropyrolyticIon ChromatographicDetermination of Fluoride in Coal and Geological Materials,” Analytical Chemistry,Vol 60, No. 4, 1988, pp. 365369.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
14、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY
15、 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 BottlesPolypropylene, 125-mL capacity, wide-mouth,with liner-less leakproof polyethylene screw cap, for tube-furnace pyrohydrolysate processing.5.4 VialsPolystyrene, 70-mL cap
16、acity, with liner-lessleakproof polyethylene screw cap.5.5 Dispensing BottlesPolyethylene, 250-mL capacity, forthe standard fluorine solution (6.3.1) and of 600-mL capacityfor the absorption solution (6.3.3) and buffer (6.3.5).5.6 MicropipettesPolypropylene or other suitablepolymer, variable volumes
17、 ranging from 0.1 mL to at least 2.0mL. This is a satisfactory alternative to the 250-mL dispensingbottle (5.5), for the delivery of small volumes of the standardfluorine solution.5.7 Glass Dropper Bottle30-mL capacity for dispensingglacial acetic acid.5.8 BalanceAnalytical, with a sensitivity of 0.
18、1 mg. Thebalance shall be checked periodically to determine its accuracy.5.9 Apparatus for Tube-Furnace Pyrohydrolysis (see Fig.1):5.9.1 Silica Tube-Furnace and Accessories:5.9.1.1 Quartz Combustion TubeTranslucent, pure silica(25-mm outside diameter, 20-mm inside diameter) of lengthappropriate to t
19、he particular furnace used. Preferably, the gasoutlet end should be narrowed to a tubulure of approximately7 mm in diameter.NOTE 1Combustion tubes of alternative refractory compositions donot have adequate thermal stress characteristics for operation with this testmethod.5.9.1.2 Silicone Stoppers20
20、mm in diameter, positioned atinlet end and outlet, if applicable, of silica combustion tube(5.9.1.1).FIG. 1 Pyrohydrolysis Furnace and Fluorine Absorption AssemblyD5987 96 (2015)25.9.1.3 Combustion BoatsUnglazed porcelain, high alu-mina content, approximately 97 mm by 16 mm by 12 mm,preheated at 100
21、0C for 1 h.5.9.1.4 Silica Pusher and T-TubeA silica push rod ofdimensions 5 mm in diameter by 50 cm long, fused at one endto provide a flat disk surface of 10 to 12 mm in diameter andhaving a piece of magnetic steel affixed to the other end byepoxy resin. The T-tube, 50 cm long, is composed of boros
22、ili-cate glass and protrudes 10 mm into the silica tube (5.9.1.1)through a stopper (5.9.1.2). A magnet is used to move thepusher inside the T-tube.5.9.1.5 Combustion FurnaceCapable of reaching a maxi-mum temperature of at least 1100C.5.9.1.6 Heating Tape and Power RegulatorTo preventcondensation fro
23、m forming in the outlet end of the combustiontrain.5.9.2 Steam Generator (Fig. 1):5.9.2.1 Round Bottom FlaskGlass, 2-L capacity.5.9.2.2 Heating MantleOf size sufficient to heat the roundbottom flask (5.9.1.1).5.9.2.3 Y-pieceGlass, 10 mm in diameter.5.9.2.4 Gas Distribution TubeZero porosity.5.9.2.5
24、StopcocksOne three-way and one two-way.5.9.2.6 FlowmeterCapable of regulating and delivering atleast 1000 mL/min of the oxygen.5.9.3 Absorption Vessel Components:5.9.3.1 Separatory FunnelGlass, 125-mL capacity forrinsing Graham Condenser into receiving flask, with stopcockand 24/40 joint with drip t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5987199620151742STANDARDTESTMETHODFORTOTALFLUORINEINCOALANDCOKEBYPYROHYDROLYTICEXTRACTIONANDIONSELECTIVEELECTRODEORIONCHROMATOGRAPHMETHODS

链接地址:http://www.mydoc123.com/p-521234.html