1、Designation: D 5985 02 (Reapproved 2008)An American National StandardStandard Test Method forPour Point of Petroleum Products (Rotational Method)1This standard is issued under the fixed designation D 5985; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers an alternative procedure for the determination of pour poin
3、t of petroleumproducts using an automatic apparatus.1. Scope1.1 This test method covers the determination of pour pointof petroleum products by an automatic instrument that con-tinuously rotates the test specimen against a suspended detec-tion device during cooling of the test specimen.1.2 This test
4、 method is designed to cover the range oftemperatures from 57 to +51C; however, the range oftemperatures included in the 1992 interlaboratory programonly covered the temperature range of 39 to +6C (see 13.4).1.3 This test method determines the no-flow point of petro-leum products by detection of the
5、 crystal structure or viscosityincrease, or both, in the sample that is sufficient to impede flowof the specimen.1.4 This test method is not intended for use with crude oils.NOTE 1The applicability of this test method on residual fuel sampleshas not been verified. For further information on applicab
6、ility, refer to13.4.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standa
7、rd to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177
8、 Practice for Automatic Sampling of Petroleum andPetroleum Products2.2 Energy Institute Standards:3IP 15 Test Method for Pour Point of Petroleum Products3. Terminology3.1 Definitions:3.1.1 pour point, nin petroleum products, the lowesttemperature at which movement of the test specimen isobserved und
9、er prescribed conditions of test.3.2 Definitions of Terms Specific to This Standard:3.2.1 no-flow point, nin petroleum products, the tempera-ture of the test specimen at which a wax crystal structure orviscosity increase, or both, impedes movement of the surfaceof the test specimen under the conditi
10、ons of the test.3.2.2 DiscussionThe no-flow point occurs when, uponcooling, the formation of wax crystal structures or viscosityincrease, or both, have progressed to the point where theapplied observation device no longer detects movement underthe conditions of the test. The preceding observation te
11、mpera-ture, at which flow of the test specimen is last observed, is thepour point.3.2.3 pour point at 3C testing intervals, nin petroleumproducts, the temperature calculated by rounding the no-flowpoint of the test specimen to the next higher integer which is amultiple of 3C.3.2.4 DiscussionThe no-f
12、low point can be measured witha resolution of 0.1C in this test method. In Test Method D97observations for no-flow are in 3C intervals and when resultswith a similar format to Test Method D97are required, thiscalculation shall be performed. Some apparatus can performthis calculation automatically.1T
13、his test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved May 1, 2008. Published September 2008. Originallyapproved in 1996. Last previous edition approved in
14、2002 as D 598502.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cav
15、endish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5 rotational, nin this standard, the technique of turn-ing the test specimen jar in an upright position upon a turntabl
16、ewith a stationary positioned, temperature sensor containingpendulum, inserted into the test specimen.3.2.6 DiscussionUpon cooling of the test specimen, theresultant crystal formation or viscosity increase in the speci-men exerts force upon the pendulum, offsetting the stationaryposition and causing
17、 detection of the no-flow point.4. Summary of Test Method4.1 After inserting the test specimen into the automatic pourpoint apparatus, and initiation of the program, the test speci-men is heated and then cooled by maintaining a constanttemperature differential between the cooling block and thesample
18、. The test specimen is continuously tested for flowcharacteristics by rotating the test specimen cup at approxi-mately 0.1 rpm against a stationary, counter-balanced, sphere-shaped pendulum. The temperature of the test specimen atwhich a crystal structure or a viscosity increase, or both, withinthe
19、test specimen causes the displacement of the pendulum isrecorded with a resolution of 0.1C. The test specimen is thenheated to the original starting temperature.5. Significance and Use5.1 The pour point of a petroleum product is an index of thelowest temperature of its utility for certain applicatio
20、ns. Flowcharacteristics, such as pour point, can be critical for thecorrect operation of lubricating systems, fuel systems, andpipeline operations.5.2 Petroleum blending operations require precise measure-ment of the pour point.5.3 This test method can determine the temperature of thetest specimen w
21、ith a resolution of 0.1C at which eithercrystals have formed or viscosity increases sufficiently toimpede movement of the petroleum product.5.4 This test method yields a pour point in a format similarto Test Method D97/IP 15 when the 3C interval results arereported.NOTE 2Since some users may wish to
22、 report their results in a formatsimilar to Test Method D97(in 3C intervals) the precisions were derivedfor the temperatures rounded to the 3C intervals. For statements on biasrelative to Test Method D97, see 13.3.5.5 This test method has better repeatability and comparablereproducibility relative t
23、o Test Method D97as measured in the1992 interlaboratory program. (See Section 13.)6. Apparatus6.1 Automatic Apparatus4The automatic pour point appa-ratus described in the Annex A1 consists of a microprocessorcontrolled measuring unit that is capable of heating, cooling,rotating, and recording the te
24、mperature of the test specimen.The apparatus shall be equipped with a digital display, cooling/heating block assembly, turntable, test specimen cup andmeasuring head containing a counter-balanced pendulum andtemperature measuring device.6.2 Test Specimen CupThe test specimen cup is a flatbottom alum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD598520022008317STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTSROTATIONALMETHOD 石油 产品 标准 试验 方法

链接地址:http://www.mydoc123.com/p-521228.html