ASTM D5971 D5971M-2016 red 0556 Standard Practice for Sampling Freshly Mixed Controlled Low-Strength Material《新拌受控低强度材料抽样用标准实施规程》.pdf
《ASTM D5971 D5971M-2016 red 0556 Standard Practice for Sampling Freshly Mixed Controlled Low-Strength Material《新拌受控低强度材料抽样用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5971 D5971M-2016 red 0556 Standard Practice for Sampling Freshly Mixed Controlled Low-Strength Material《新拌受控低强度材料抽样用标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5971/D5971M 13D5971/D5971M 16Standard Practice forSampling Freshly Mixed Controlled Low-Strength Material1This standard is issued under the fixed designation D5971/D5971M; the number immediately following the designation indicates theyear of original adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice explains the procedure for obtaining a representative sample of freshly mixed controlled
3、 low-strength material(CLSM) as delivered to the project site on which tests are to be performed to determine compliance with quality requirements ofthe specifications under which the CLSM is furnished (Note 1). This practice includes sampling from revolving-drum truck mixersand from agitating equip
4、ment used to transport central-mixed CLSM. This Practice is based on Practice C172 for concrete.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used i
5、ndependently of the other. Combining values from thetwo systems may result in non-conformance with the standard.NOTE 1Composite samples are required by this practice unless specifically excepted by procedures governing the tests to be performed, such as teststo determine uniformity of consistency an
6、d mixer efficiency. Procedures used to select the specific test batches are not described in this practice. It isrecommended that random sampling be used to determine overall specification compliance.1.3 This standard does not purport to address all of the safety concerns, if any, associated with it
7、s use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin andtissue upon prolon
8、ged exposure.2)1.4 This practice offers a set of instructions for performing one or more specific operations. This document cannot replaceeducation or experience and should be used in conjunction with professional judgement. Not all aspects of this practice may beapplicable in all circumstances. Thi
9、s ASTM standard is not intended to represent or replace the standard of care by which theadequacy of a given professional service must be judged, nor should this document be applied without consideration of a projectsmany unique aspects. The word “standard” in the title of this document means only t
10、hat the document has been approved throughthe ASTM consensus process.2. Referenced Documents2.1 ASTM Standards:3C172 Practice for Sampling Freshly Mixed ConcreteD653 Terminology Relating to Soil, Rock, and Contained FluidsD3740 Practice for Minimum Requirements for Agencies Engaged in Testing and/or
11、 Inspection of Soil and Rock as Used inEngineering Design and ConstructionD4832 Test Method for Preparation and Testing of Controlled Low Strength Material (CLSM) Test CylindersD6023 Test Method for Density (Unit Weight), Yield, Cement Content, and Air Content (Gravimetric) of ControlledLow-Strength
12、 Material (CLSM)D6103 Test Method for Flow Consistency of Controlled Low Strength Material (CLSM) (Withdrawn 2013)43. Terminology3.1 DefinitionsFor common definitions of terms in this standard, refer to Terminology D653.3.1 Definitions of Terms Specific to This Standard:Definitions:1 This practice i
13、s under the jurisdiction of ASTM Committee D18 on Soil and Rock and is the direct responsibility of Subcommittee D18.15 on Stabilization WithAdmixtures.Current edition approved Aug. 1, 2013Dec. 1, 2016. Published August 2013December 2016. Originally approved in 1995. Last previous edition approved i
14、n 20072013as D5971 07.D5971 13. DOI: 10.1520/D5971-13.10.1520/D5971_D5971M-16.2 Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of ASTM Standards, Vol 04.02.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at se
15、rviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of
16、 an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as pub
17、lished by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1 composite sample, na sample that is constructed by combini
18、ng equal portions of grab samples taken at two or moreregularly spaced intervals during discharge of the middle portion of the batch of CLSM.3.1.1 For definitions of common technical terms in this standard, refer to Terminology D653.3.1.2 controlled low-strength material (CLSM), na mixture of Portla
19、nd cement, fly ash, aggregates, water, and possiblychemical admixtures that, as the cement hydrates, forms a soil replacement material. The CLSM is a self compacting, flowable,cementitious material that is primarily used as a backfill or structural fill instead of compacted fill or unsuitable native
20、 soil.Depending on the amount of water used in the CLSM mixture, it can be placed as a non-flowable compacted material or as amortar. soil, aggregates (sand, gravel, or both), cementitious materials, water, and sometimes admixtures, that hardens into amaterial with a higher strength than the soil, b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5971D5971M2016RED0556STANDARDPRACTICEFORSAMPLINGFRESHLYMIXEDCONTROLLEDLOWSTRENGTHMATERIAL 受控 强度

链接地址:http://www.mydoc123.com/p-521183.html