ASTM D5769-2010(2015) 0829 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成.pdf
《ASTM D5769-2010(2015) 0829 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成.pdf》由会员分享,可在线阅读,更多相关《ASTM D5769-2010(2015) 0829 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《采用气相色谱 质谱法测定成.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5769 10 (Reapproved 2015)Standard Test Method forDetermination of Benzene, Toluene, and Total Aromatics inFinished Gasolines by Gas Chromatography/MassSpectrometry1This standard is issued under the fixed designation D5769; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of benzene
3、,toluene, other specified individual aromatic compounds, andtotal aromatics in finished motor gasoline, including gasolinescontaining oxygenated blending components, by gaschromatography/mass spectrometry (GC/MS).1.2 This test method has been tested for the followingconcentration ranges, in liquid v
4、olume percent, for the follow-ing aromatics: benzene, 0.1 % to 4 %; toluene, 1 % to 13 %;and total (C6 to C12) aromatics, 10 % to 42 %. The round-robin study did not test the method for individual hydrocarbonprocess streams in a refinery, such as reformates, fluid catalyticcracked naphthas, and so f
5、orth, used in the blending ofgasolines.1.3 Results are reported to the nearest 0.01 % for benzeneand 0.1 % for the other aromatics by liquid volume.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not p
6、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to its use.2. Referenced Documents2.1 ASTM Standar
7、ds:2D1298 Test Method for Density, Relative Density, or APIGravity of Crude Petroleum and Liquid Petroleum Prod-ucts by Hydrometer MethodD4052 Test Method for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum andPetroleum Pro
8、ductsD4307 Practice for Preparation of Liquid Blends for Use asAnalytical Standards3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 aromaticany hydrocarbon compound containing abenzene or naphthalene ring.3.1.2 calibrated aromatic componentthe individual aro-matic components th
9、at have a specific calibration.3.1.3 cool on-column injectorin gas chromatography,adirect sample introduction system that is set at a temperature ator below the boiling point of solutes or solvent on injection andthen heated at a rate equal to or greater than the column.Normally used to eliminate bo
10、iling point discrimination oninjection or to reduce adsorption on glass liners withininjectors, or both. The sample is injected directly into the headof the capillary column tubing.3.1.4 open split interfaceGC/MS interface used to main-tain atmospheric pressure at capillary column outlet and toelimi
11、nate mass spectrometer vacuum effects on the capillarycolumn. Can be used to dilute the sample entering the massspectrometer to maintain response linearity.3.1.5 reconstructed ion chromatogram (RIC)a limitedmass chromatogram representing the intensities of ion massspectrometric currents for only tho
12、se ions having particularmass to charge ratios. Used in this test method to selectivelyextract or identify aromatic components in the presence of acomplex hydrocarbon matrix, such as gasoline.3.1.6 retention gapin gas chromatography, refers to adeactivated precolumn which acts as a zone of low reten
13、tionpower for reconcentrating bands in space. The polarity of theprecolumn must be similar to that of the analytical column.3.1.7 split ratioin capillary gas chromatography, the ratioof the total flow of carrier gas to the sample inlet versus theflow of the carrier gas to the capillary column, expre
14、ssed by:1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.04.0M on Mass Spectroscopy.Current edition approved June 1, 2015. Published July 2015. Originally approvedin 1995. Last pre
15、vious edition approved in 2010 as D5769 10. DOI: 10.1520/D5769-10R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
16、website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1split ratio 5 S1C!/C (1)where:S = flow rate at the splitter vent, andC = flow rate at the column outlet.3.1.8 total ion chromatogram (TIC)mass spectrometercomputer output represe
17、nting either the summed intensities ofall scanned ion currents or a sample of the current in the ionbeam for each spectrum scan plotted against the correspondingspectrum number. Generally, it can be correlated with a flameionization detector chromatogram.3.1.9 uncalibrated aromatic componentindividu
18、al aro-matics for which a calibration is not available. These compo-nents are estimated from the calibration of several calibratedaromatic components.3.1.10 wall coated open tubular (WCOT)a type of capil-lary column prepared by coating or bonding the inside wall ofthe capillary with a thin film of s
19、tationary phase.4. Summary of Test Method4.1 A gas chromatograph equipped with a dimethylpolysi-loxane WCOT column is interfaced to a fast scanning massspectrometer that is suitable for capillary column GC/MSanalyses. The sample is injected either through a capillarysplitter port or a cool-on-column
20、 injector capable of introduc-ing a small sample size without overloading the column. Thecapillary column is interfaced directly to the mass spectrometeror by way of an open split interface or other appropriate device.4.2 Calibration is performed on a mass basis, using mixturesof specified pure arom
21、atic hydrocarbons. Volume percent datais calculated from the densities of the individual componentsand the density of the sample. A multipoint calibration consist-ing of at least five levels and bracketing the expected concen-trations of the specified individual aromatics is required.Specified deute
22、rated hydrocarbons are used as the internalstandards, for example, d6-benzene for quantitating benzene.Unidentified aromatic hydrocarbons present that have not beenspecifically calibrated for are quantitated using the calibrationof an adjacent calibrated compound and summed with the otheraromatic co
23、mponents to obtain a total aromatic concentrationof the sample.4.3 Specified quality control mixture(s), such as syntheticquality control mixtures must be analyzed to monitor theperformance of the calibrated GC/MS system. Analysis of agasoline as a reference material is strongly recommended.5. Signi
24、ficance and Use5.1 Test methods to determine benzene and the aromaticcontent of gasoline are necessary to assess product quality andto meet fuel regulations.5.2 This test method can be used for gasolines that containoxygenates (alcohols and ethers) as additives. It has beendetermined that the common
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5769201020150829STANDARDTESTMETHODFORDETERMINATIONOFBENZENETOLUENEANDTOTALAROMATICSINFINISHEDGASOLINESBYGASCHROMATOGRAPHYMASSSPECTROMETRY

链接地址:http://www.mydoc123.com/p-520634.html