ASTM D5419-2014 red 0700 Standard Test Method for Environmental Stress Crack Resistance (ESCR) of Threaded Plastic Closures.pdf
《ASTM D5419-2014 red 0700 Standard Test Method for Environmental Stress Crack Resistance (ESCR) of Threaded Plastic Closures.pdf》由会员分享,可在线阅读,更多相关《ASTM D5419-2014 red 0700 Standard Test Method for Environmental Stress Crack Resistance (ESCR) of Threaded Plastic Closures.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5419 09D5419 14Standard Test Method forEnvironmental Stress Crack Resistance (ESCR) of ThreadedPlastic Closures1This standard is issued under the fixed designation D5419; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method determines the susceptibility of threaded plastic closures to failure due to environme
3、ntal stress cracking(ESC).1.2 In use, threaded plastic closures can contact agents that appreciably reduce the stress at which cracks form. Examples ofsuch agents are: soaps, detergents, oils, and liquid bleaches.1.3 Major factors that influence environmental stress crack resistance (ESCR) of thread
4、ed plastic closures include the closurematerial(s), closure design, molded-in stress, and applied stress.1.4 This procedure can be applied to all closures, but is particularly applicable to closures made from plastics based onpolypropylene (PP) or polystyrene (PS).1.5 The values stated in SIinch-pou
5、nd units are to be regarded as the standard. The values given in parentheses are forinformation only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and hea
6、lth practices and determine the applicability of regulatorylimitations prior to use. Specific precautionary statements are given in Section 8 and 6.2.NOTE 1There is no known ISO equivalent to this test method.standard.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics
7、 for TestingD883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating to PlasticsD2911 Specification for Dimensions and Tolerances for Plastic BottlesD3198 Test Method for Application and Removal Torque of Threaded or Lug-Style ClosuresE145 Specification for Gravity-Conve
8、ction and Forced-Ventilation OvensE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsExcept for those terms below, see Terminologies D883 and D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 assemblyclosure appl
9、ied to a bottle finish.3.2.2 failureduring this test, any visible crack.3.2.2.1 Discussion1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.19 on Film, Sheeting, and MoldedProducts.Current edition approved Nov. 15, 200
10、9Nov. 15, 2014. Published December 2009December 2014. Originally approved in 1993. Last previous edition approved in20032009 as D5419 95D5419 09.(2003). DOI: 10.1520/D5419-09.10.1520/D5419-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serv
11、iceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version.
12、Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section a
13、ppears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1A crack does not have to penetrate the closure wall to be considered a failure.3.2.3 finishfixture representing the threaded portion of the bottle.3.2.4
14、 threaded closurepart applied to seal bottle as specified in Specification D2911.4. Summary of Test Method4.1 This test method consists of applying closures at a specified application torque to rigid finishes (of polysulfone or otherappropriate resin), immersing the assembly in a potential stress-cr
15、acking agent, and observing and reporting time-to-failure.5. Significance and Use5.1 This test method compares closures for ESCR. Suitable variables are: closure materials, closure designs, processes, appliedtorque, and stress-crack agents.5.2 Results can be used for estimating shelf life of closure
16、s in terms of ESCR. This requires that the user has calibrated failuretime in this test to failure time in the field for actual packaging systems.6. Apparatus6.1 Wide-Mount Gallon Jars, glass, PET, or other suitable material. Must have lined closures to ensure air-tight seal. Use onejar per sample.6
17、.2 Circulating-Air Oven, capable of maintaining a temperature of 50 6 1C (critical in this application). See SpecificationE145 for a procedure for confirming satisfactory uniformity of temperature within the oven. There is no air-flow requirement inthis application. An environmental room with these
18、properties is also suitable. (WarningA high-temperature safety switch ishighly recommended on this oven. Some test liquids can cause extreme pressure to build up upon heating. Under these conditionsit is possible that the test jars maywill rupture with explosive force. The Set the override cutoff sw
19、itch should be set to turn offthe oven if the test temperature is exceeded by 10C or more.)6.3 Tongs, for sample removal and inspection.6.4 Bottle Finishes, polysulfone or other material of equivalent stiffness and thermal coefficient of expansion, to which closuresare applied. These can be made by
20、injection molding or by machining rod stock. See Fig. 1 for a drawing of a typical fixture. Usean appropriate size based on closure and bottle specifications.6.5 Torque Meter, with capacity of at least 5 torque Nm, calibrated or verified within the past 12 months.6.6 Plastic Test Closures, lined or
21、unlined closure based on specifications.NOTE 2To ensure that full crystallization has essentially been achieved, PP-based closures should condition for at least three weeks before testingand PS closures for at least 16 h.NOTE 3To convert lbf-in. torque to Nm torque, multiply by 0.113.7. Reagents and
22、 Materials7.1 Test SolutionUse solution for which the closure is intended.8. Hazards8.1 Always wear protective equipment, such as goggles, gloves, and aprons, appropriate to the product hazard when setting upor inspecting closures.9. Test Specimens9.1 Normal sample size is 20 closures, typical of lo
23、ts to be tested. It is strongly advisable to run the test in duplicate (two setsof 20) or to sample more than one lot.9.2 Visually inspect each closure to be tested. Replace any that appear defective or irregular.10. Conditioning10.1 ConditioningAfter aging in accordance with 6.6, condition closures
24、 and bottle finishes at 23 6 2C and 50 6 10 %relative humidity for not less than 40 h prior to test, in accordance with Procedure A of Practice D618 unless otherwise specifiedby agreement or the relevant ASTM material specification. Condition test solution at 50 6 1C until it reaches 50 6 1C (16 hno
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54192014RED0700STANDARDTESTMETHODFORENVIRONMENTALSTRESSCRACKRESISTANCEESCROFTHREADEDPLASTICCLOSURESPDF

链接地址:http://www.mydoc123.com/p-519731.html