ASTM D5228-2016 Standard Test Method for Determination of Butane Working Capacity of Activated Carbon《测定活性炭丁烷工作容量的标准试验方法》.pdf
《ASTM D5228-2016 Standard Test Method for Determination of Butane Working Capacity of Activated Carbon《测定活性炭丁烷工作容量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5228-2016 Standard Test Method for Determination of Butane Working Capacity of Activated Carbon《测定活性炭丁烷工作容量的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5228 92 (Reapproved 2015)D5228 16Standard Test Method forDetermination of Butane Working Capacity of ActivatedCarbon1This standard is issued under the fixed designation D5228; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the butane working capacity (BWC) of new granular acti
3、vated carbon. TheBWC is defined as the difference between the butane adsorbed at saturation and the butane retained per unit volume of carbon aftera specified purge. The test method also produces a butane activity value that is defined as the total amount of butane adsorbed onthe carbon sample and i
4、s expressed as a mass of butane per unit weight or volume of carbon.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use.
5、 It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For a specific hazard statement, see 7.1.2. Referenced Documents2.1 ASTM Standards:2D2652 Terminology Relating to Activate
6、d CarbonD2854 Test Method for Apparent Density of Activated CarbonD2867 Test Methods for Moisture in Activated CarbonD3195 Practice for Rotameter CalibrationE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE300 Practice for Sampling Industrial ChemicalsE691 Practice for Cond
7、ucting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 Definitions For definitions of terms used in this test method, refer to Terminology D2652.4. Summary of Test Method4.1 An activated carbon bed of known volume and mass is saturated with butane vapor. The mas
8、s adsorbed at saturation isnoted. The carbon bed is then purged under prescribed conditions with dry hydrocarbon free air. The loss of mass is the BWC andis expressed as mass of butane per unit volume of carbon.5. Significance and Use5.1 The BWC, as determined by this test method, is a measure of th
9、e ability of an activated carbon to adsorb and desorb butanefrom dry air under specified conditions. It is useful for quality control and evaluation of granular activated carbons that are usedin applications where the adsorption of butane and desorption with dry air are of interest. The BWC can also
10、 provide a relativemeasure of the effectiveness of the tested activated carbons on other adsorbates.5.2 The butane activity and retentivity can also be determined under the conditions of the test. The butane activity is anindication of the micropore volume of the activated carbon sample. The butane
11、retentivity is an indication of the pore structureof the activated carbon sample.1 This test method is under the jurisdiction of ASTM Committee D28 on Activated Carbon and is the direct responsibility of Subcommittee D28.04 on Gas PhaseEvaluation Tests.Current edition approved Oct. 1, 2015June 1, 20
12、16. Published October 2015July 2016. Originally approved in 1992. Last previous edition approved in 20102015 asD5228 92 (2010).(2015). DOI: 10.1520/D5228-92R15.10.1520/D5228-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. Fo
13、r Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may n
14、ot be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor
15、Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Water Bath, capable of maintaining a temperature of 25 6 0.2C and of sufficient depth so the entire carbon bed in thesample tube is immersed in the water. A 6-mm OD copper tube with an immersed length of 1.9 m (Fig.
16、1) provides adequate heattransfer for gas temperature control.6.2 Sample Tube, as shown in Fig. 2. The glass plate with holes is preferred to a fritted disk to support the carbon, since fritteddisks can vary widely in pressure drop.6.3 Flow Meters, one capable of delivering air at 0 to 500 mL/min, a
17、nd one capable of delivering butane at 0 to 500 mL/min,both calibrated in accordance with Practice D3195.6.4 Balance, capable of weighing to within 60.01 g.6.5 Fill DeviceThe vibration feed device used in Test Method D2854, Figs. 1 through 4, is preferred.6.6 Buret, Class A, 25 mL capacity.6.7 Appar
18、atus Assembly shown in Fig. 1.7. Reagents7.1 n-Butane, C. P. Grade. (WarningButane is a flammable gas with a flash point of 138C and a boiling point of 0.5C.Its specific gravity is 2.046 relative to air. Butane may be narcotic in high concentrations and is considered a simple asphyxiant.If the entir
19、e apparatus is not set up in a fume hood, provision must be made to vent the gas coming from the discharge stem ofthe sample tube.)7.2 Dry Air, free of organics, with a dew point no higher than 32C.8. Sampling8.1 For guidance in sampling granular activated carbon, refer to Practice E300.9. Calibrati
20、on of a Sample Tube9.1 Clean and dry the sample tube to prevent any water droplets from adhering to the inner surface of the tube.9.2 Using distilled water, carefully fill the sample tube through the narrow side stem to prevent the introduction of any airbubbles.9.2.1 Hold the sample tube upright wh
21、ile slowly introducing the distilled water. Air bubbles have a tendency to form directlybelow the retainer plate of the tube.9.3 Clamp the filled sample tube in an upright position to a ring stand and stopper the narrow side stem.FIG. 1 Butane Working Capacity Apparatus SchematicD5228 1629.4 Using a
22、 pipet, carefully remove the water from the sample tube to the top of the retainer plate. Caution must be taken sono water is removed from below the retainer plate creating air bubbles that would result in a spurious calibration of the sampletube. If this occurs, the tube must be refilled by repeati
23、ng 9.1 through 9.3.9.5 Using the buret, fill the sample tube with 16.7 6 0.05 mL of water, then etch the tube at the level of the meniscus.10. Maintenance of Bath Water10.1 In order to prevent mold formation, the bath water should be changed periodically.11. Procedure11.1 Dry an adequate sample as p
24、rescribed in Test Methods D2867, Section 4.11.2 Determine the apparent density in accordance with Test Method D2854 and record.11.3 Accurately weigh the empty, dry sample tube and stoppers to the nearest 0.01 g and record.11.4 Fill the adsorption tube with carbon to the etch mark at a rate of 0.35 t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52282016STANDARDTESTMETHODFORDETERMINATIONOFBUTANEWORKINGCAPACITYOFACTIVATEDCARBON 测定 活性炭 丁烷 工作

链接地址:http://www.mydoc123.com/p-519208.html