ASTM D5153-2004 Standard Test Method for Palladium in Molecular Sieve Catalyst by Atomic Absorption《用原子吸收法测定分子筛催化剂中钯的标准测试方法》.pdf
《ASTM D5153-2004 Standard Test Method for Palladium in Molecular Sieve Catalyst by Atomic Absorption《用原子吸收法测定分子筛催化剂中钯的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5153-2004 Standard Test Method for Palladium in Molecular Sieve Catalyst by Atomic Absorption《用原子吸收法测定分子筛催化剂中钯的标准测试方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5153 04Standard Test Method forPalladium in Molecular Sieve Catalyst by AtomicAbsorption1This standard is issued under the fixed designation D 5153; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of palladiumin molecular sieve-containing fresh catalysts with about 0.5weight % o
3、f palladium.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
4、Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and StatisticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Metho
5、d2.2 U.S. Federal Specification:Federal Spec. NNN-P-395C Tolerance for Class A Pipets33. Summary of Test Method3.1 The test sample is treated with a mixture of sulfuric andhydrofluoric acids. Upon dissolution, the excess hydrofluoricacid is expelled. Aqua regia and lanthanum chloride are addedand th
6、e solution is diluted to a specific volume. Palladiumconcentration is determined by atomic absorption spectropho-tometry. Absorbance of the samples is bracketed using a set ofnarrow range, matrix matched standards. A second sample,taken at the same time as the analysis sample, is used todetermine lo
7、ss on ignition.4. Significance and Use4.1 This test method provides a means of determining thepalladium content in fresh catalysts containing molecularsieves.4.2 This test method is not intended to cover samplescontaining precious metals other than palladium.5. Apparatus5.1 Analytical Balance, capab
8、le of weighing to nearest 0.1mg.5.2 Atomic absorption spectrophotometer.5.3 Beakers, TFE-fluorocarbon, 100-mL.5.4 Crucibles, porcelain, 10-mL.5.5 Crucible Cover, porcelain, for 10-mL crucible.5.6 Desiccator.5.7 Flasks, Erlenmeyer, 2000-mL.5.8 Graduated Cylinders, glass, 5-mL, 10-mL, 25-mL, 50-mL, 25
9、0-mL, 500-mL, 1000-mL.5.9 Graduated Cylinder, plastic, 10-mL.5.10 Hot plate.5.11 Muffle furnace, electrically heated, capable of 1000C.5.12 Pipets, 4-mL, 6-mL, 8-mL, 10-mL.5.13 Volumetric Flasks, 100-mL, 500-mL.5.14 Watch glasses, TFE-fluorocarbon, for 100-mL beaker.5.15 Weighing Papers.6. Reagents
10、and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Oth
11、er grades may beused provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32
12、.03 on ChemicalComposition.Current edition approved April 1, 2004. Published April 2004. Originallyapproved in 1991. Last previous edition approved in 1997 as D 515391(1997).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
13、Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098.4Reagent Chemicals, American Chemical Society Specifications
14、, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc
15、. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Specification D 1193.6.3 Hydrochloric aci
16、d, concentrated, 36.538.0 wt. % or 12M, sp gr 1.18.6.4 Hydrofluoric acid, concentrated, 48.051.0 wt. % or28.9 M, sp gr 1.17.6.5 Nitric acid, concentrated, 69.071.0 wt. % or 15.7 M, spgr 1.41.6.6 Sulfuric acid, concentrated, 95.098.0 wt. % or 18 M, spgr 1.84.6.7 Aluminum Oxide (Al2O3).6.8 Lanthanum C
17、hloride (LaCl37H2O).6.9 Palladium Wire, 99.99 %.6.10 Aqua RegiaMix three parts by volume of concen-trated hydrochloric acid (12 M) and one part by volume ofconcentrated nitric acid (15.7 M) immediately before use.6.11 Sulfuric Acid, 15.816.3 wt. % or 3MCautiously add250 mL of concentrated sulfuric a
18、cid (18 M) to 1250 mL ofwatermix well and allow to cool.6.12 Palladium Standard Solution, 500 mg/LDissolve0.2500 6 0.0001 g of palladium wire (99.99 %) in 25 mL ofaqua regia. Evaporate the solution to dryness on a steam bath.Dissolve the remaining salts by addition of 25 mL of concen-trated hydrochl
19、oric acid (12 M) and 25 mL of distilled water.Transfer the solution to a 500 mL volumetric flask and dilute tovolume when cool.NOTE 1A commercially available atomic absorption palladium refer-ence solution may be used if it is known to be reliable.6.13 Lanthanum Chloride SolutionDissolve 25.5 g ofla
20、nthanum chloride (LaCl37H2O) in distilled water, dilute to100 mL and mix well. This solution serves as an ionizationsuppressor in atomic absorption.6.14 Desiccant, molecular sieve, type 4A.7. Procedure7.1 Preparation of Calibration Standards:7.1.1 If the concentration of aluminum oxide in the sample
21、is unknown, digest a representative sample in acid and deter-mine the aluminum concentration by atomic absorption spec-trophotometry.7.1.2 Transfer 30 mL of sulfuric acid (3M) to five TFE-fluorocarbon beakers.7.1.3 To each beaker add the equivalent weight of aluminumoxide that would be present in 0.
22、8000 g of sample asdetermined in 7.1.1.NOTE 2If it is available, 0.800 g of catalyst base material may besubstituted for the aluminum oxide.7.1.4 Transfer 0, 4, 6, 8 and 10 mL of the 500 mg/Lpalladium standard to the five TFE-fluorocarbon beakers.7.1.5 Add 10 mL of concentrated hydrofluoric acid to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD51532004STANDARDTESTMETHODFORPALLADIUMINMOLECULARSIEVECATALYSTBYATOMICABSORPTION 原子 吸收 测定 分子筛 催化剂

链接地址:http://www.mydoc123.com/p-519003.html