《ASTM D5131-1990(2007) Standard Guide for Record Keeping for Electrodialysis Electrodialysis Reversal Systems《电渗析 反向电渗析系统用记录保存的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5131-1990(2007) Standard Guide for Record Keeping for Electrodialysis Electrodialysis Reversal Systems《电渗析 反向电渗析系统用记录保存的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5131 90 (Reapproved 2007)Standard Guide forRecord Keeping for Electrodialysis/Electrodialysis ReversalSystems1This standard is issued under the fixed designation D 5131; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers procedures for well defined recordkeeping for electrodialysis (ED) and electrodialysi
3、s reversal(EDR) systems.1.2 This guide includes a start up report and record keepingfor ED/EDR and pretreatment operating and maintenance data.1.3 This guide is applicable to all waters but is not neces-sarily complete for waste waters.1.4 This is a guide only and should not be construed as acomplet
4、e delineation of all record keeping required for aspecific application.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine th
5、e applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1125 Test Methods for Electrical Conductivity and Re-sistivity of WaterD 1129 Terminology Relating to WaterD 1253 Test Method for Residual Chlorine in WaterD 1889 Test Method for Turbidity of Water3D
6、 4189 Test Method for Silt Density Index (SDI) of WaterD 5091 Guide for Water Analysis for Electrodialysis/Electrodialysis Reversal Applications3. Terminology3.1 DefinitionsFor definitions of terms used in this guiderefer to Terminology D 1129.4. Significance and Use4.1 Proper operation and maintena
7、nce of an ED/EDR sys-tem and any associated pretreatment system are key factors inobtaining optimum performance. This guide provides thenecessary input data for the evaluation of the performance ofthe ED/EDR system, the pretreatment system, and the me-chanical equipment in the plant.4.2 This guide i
8、s for general guidance only and must not beused in place of the operating manuals and manufacturersrecommendations for specific equipment or a specific applica-tion.4.3 Site dependent, equipment design and regulatory re-quirement factors prevent specific recommendations for allrecord keeping. Thus,
9、only general record keeping relating tooperation and maintenance is covered by this guide.5. Procedure5.1 Start Up Report:5.1.1 Provide a complete description of the water source,pretreatment system, ED/EDR plant, and post treatment equip-ment. This can be done by using the system flow diagram andeq
10、uipment material and instrumentation lists.5.1.2 Provide a listing of all specific chemicals used withtheir design dosage rates.5.1.3 Provide a listing of all design parameters for pres-sures, flows, water analysis for raw water and ED/EDR feedproduct and brine waste, temperature, and dc power appli
11、ed tothe ED/EDR system.5.1.4 Provide a record of instrument calibrations in accor-dance with manufacturers recommendations.5.1.5 Record initial performance of the pretreatment, ED/EDR, and post treatment systems as provided in 5.1, 5.3, and5.4 respectively.5.2 ED/EDR Operating Data:NOTE 1ED/EDR proc
12、ess monitoring equipment and site specificmonitoring equipment vary with manufacturers designs. Consult theequipment manufacturer to determine the specific listed items to bemonitored.NOTE 2The periodic polarity reversal in reversing electrodialysissystems upsets the process equilibrium. Data should
13、 not be taken during1This guide is under the jurisdiction of ASTM Committee D19 on Water and isthe direct responsibility of Subcommittee D19.08 on Membranes and Ion ExchangeMaterials.Current edition approved Dec. 1, 2007. Published January 2008. Originallyapproved in 1990. Last previous edition appr
14、oved in 2001 as D 5131 90 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM I
15、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the period of reversal. Consult the equipment manufacturer to determinethe periods of time at which operating data should be taken.5.2.1 The recommended minimum frequency of data collec-tion is daily un
16、less otherwise noted. On large or criticalsystems more frequent data collection, such as once per shift,for daily items, may be justified.5.2.2 Record applicable pressures, including5.2.2.1 Feed pump discharge pressure,5.2.2.2 Cartridge filter inlet pressure,5.2.2.3 Cartridge filter outlet pressure,
17、5.2.2.4 Brine pump discharge pressure,5.2.2.5 Feed pressure to stack(s),5.2.2.6 Brine pressure to stack(s),5.2.2.7 Product pressure from stack(s),5.2.2.8 Brine pressure from stack(s),5.2.2.9 Feed/brine inlet differential pressure to stack(s),5.2.2.10 Product/brine outlet differential pressure fromst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD513119902007STANDARDGUIDEFORRECORDKEEPINGFORELECTRODIALYSISELECTRODIALYSISREVERSALSYSTEMS 电渗析 反向

链接地址:http://www.mydoc123.com/p-518939.html