ASTM D5125-2010 Standard Test Method for Viscosity of Paints and Related Materials by ISO Flow Cups《ISO流量杯法测定油漆和相关材料的粘性的标准试验方法》.pdf
《ASTM D5125-2010 Standard Test Method for Viscosity of Paints and Related Materials by ISO Flow Cups《ISO流量杯法测定油漆和相关材料的粘性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5125-2010 Standard Test Method for Viscosity of Paints and Related Materials by ISO Flow Cups《ISO流量杯法测定油漆和相关材料的粘性的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5125 10Standard Test Method forViscosity of Paints and Related Materials by ISO Flow Cups1This standard is issued under the fixed designation D5125; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the flowtime (viscosity) of Newtonian and near-Newtonian paints, andrelated coati
3、ngs and products using ISO capillary flow cups.NOTE 1If the liquid is non-Newtonian, that is shear-thinning orthixotropic, Test Methods D2196 should be used.1.2 The cup-orifice combination (ISO cup with orificediameter of 3 mm, 4 mm, 5 mm, or 6 mm)2is selected toprovide an efflux time with the range
4、 of 20 to 100 s andviscosities up to 700 cSt (700 mm2/s). The most commonlyused cup is the one with the 4-mm orifice.1.3 This test method is limited to testing materials for whichthe breakpoint of the flow from the orifice of the flow cup canbe determined with certainty. This point is difficult to d
5、eter-mine and reproduce for materials with flow times in excess of100 s due to slowing-down effects.1.4 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address the safetyconcerns, if any, assoc
6、iated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.NOTE 2The International CivilAviation Organization (ICAO) and theInternational Maritime Organization (IMO
7、) include in their regulations asimilar test (ISO 2431) to determine the viscosity of hazardous viscousliquids. The viscosity is then used to place these liquids in a hazardpackaging group depending on their viscosity/flashpoint relationship. TheU. S. Department of Transportation permits the use of
8、these regulations fortranshipment of hazardous material within the U.S. when bound forforeign destinations.2. Referenced Documents2.1 ASTM Standards:3D2196 Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational (Brookfield type) Vis-cometerD3924 Specification for Environmen
9、t for Conditioning andTesting Paint, Varnish, Lacquer, and Related MaterialsD3925 Practice for Sampling Liquid Paints and RelatedPigmented CoatingsE1 Specification for ASTM Liquid-in-Glass Thermometers2.2 ISO Documents:ISO 2431 Paints and Varnishes: Determination of FlowTime by Use of a Flow Cup43.
10、Terminology3.1 Definitions:3.1.1 dynamic viscosity, nthe ratio of the applied shearstress to shear rate.3.1.1.1 DiscussionThe SI unit for dynamic viscosity is thepascal second (Pas). The traditional unit is the centipoise (cP);1 cP = 1 mPas.3.1.2 flow time, nthe elapsed time from the moment whenthe
11、material under test starts to flow from the orifice of thefilled cup to the moment when the flow stream of material firstbreaks close to the orifice.3.1.3 kinematic viscosity, nthe ratio of the dynamic vis-cosity to the density of the liquid.3.1.3.1 DiscussionThe SI unit for kinematic viscosity isth
12、e square metre per second (m2/s). The traditional unit is thecentistokes (cSt); 1 cSt = 1 mm2/s.3.1.4 near-Newtonian liquid, na liquid in which thevariation of viscosity with shear rate is small and the effect onviscosity of mechanical disturbances such as stirring is negli-gible.1This test method i
13、s under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.24 on Physical Properties of Liquid Paints and Paint Materials.Current edition approved July 1, 2010. Published July 2010. Originally approvedi
14、n 1991. Last previous edition approved in 2005 as D5125 97 (2005). DOI:10.1520/D5125-10.2An ISO-type cup with an orifice diameter of 8 mm is available, but it is notlisted in ISO 2431 and precision and accuracy are not known.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcon
15、tact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyrigh
16、t ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.5 Newtonian liquid, na liquid in which the viscosity isindependent of the shear stress or shear rate. Compare non-Newtonian liquid.3.1.6 non-Newtonian liquid, na liquid in which the ratioof
17、shear stress to shear rate is not constant.4. Summary of Test Method4.1 The ISO flow cup is filled level full with the materialunder test that has been conditioned at the specified measuringtemperature (see 10.2.2) and the time for the material to flowthrough one of the standard orifices is determin
18、ed.5. Significance and Use5.1 This test method is useful for the determination ofpackage and application viscosities of paints and other coat-ings. It is limited to Newtonian or near-Newtonian liquids.5.2 This test method may be used similarly to ISO 2431 inconjunction with flashpoint to determine t
19、he hazard groupingof viscous liquids in international regulations.6. Apparatus6.1 ISO Capillary Flow CupsISO cups look like Fordcups, but instead of the non-capillary hole in the bottom of theFord cup, the ISO cup has a 20-mm capillary and is more likea true capillary viscometer.6.1.1 DimensionsThe
20、dimensions of the ISO flow cup andthe tolerances allowed in manufacture shall be as given in Fig.1. The most critical tolerance is the internal diameter of the jetof the cup, because the flow time is inversely proportional tothe fourth power of this dimension. The jet of the cup shall bemade of stai
21、nless steel or sintered carbide unless otherwisespecified, and the body of the cup shall be made of a materialthat is corrosion resistant and is not affected by the products tobe tested.6.1.2 ConstructionThe dimensions not specified, such aswall thickness, shall be such that no distortion of the cup
22、 canoccur in use. The external shape shown in Fig. 1 is recom-mended, but may be modified for convenience of use, ormanufacture, provided that the protruding jet of the cup isprotected from accidental damage as far as possible by anexternal protective sleeve. Such a protective sleeve shall not beimm
23、ediately adjacent to the jet, so as to prevent a capillaryaction when the material under test flows out.6.1.3 FinishThe interior surfaces of the cups, includingthe orifice, shall be smooth and free of turning marks, crevices,ledges and burrs that may cause random flow, or trap sample orcleaning mate
24、rial. The standard of finish required is equivalentto a maximum roughness of not more than 0.5 m (see Note 3).NOTE 3Roughness defined as the arithmetical mean deviation Rafrom the mean line of the profile.6.2 Thermometer, accurate to 0.2C (0.4F) and graduatedat 0.1C (0.2F) intervals. Saybolt viscosi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD51252010STANDARDTESTMETHODFORVISCOSITYOFPAINTSANDRELATEDMATERIALSBYISOFLOWCUPSISO 流量 测定 油漆 相关 材料

链接地址:http://www.mydoc123.com/p-518919.html