《ASTM D4875-2011 Standard Test Methods of Polyurethane Raw Materials Determination of the Polymerized Ethylene Oxide Content of Polyether Polyols《聚亚安酯原材料的标准试验方法 测定聚醚多醇中聚合乙撑氧含量》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4875-2011 Standard Test Methods of Polyurethane Raw Materials Determination of the Polymerized Ethylene Oxide Content of Polyether Polyols《聚亚安酯原材料的标准试验方法 测定聚醚多醇中聚合乙撑氧含量》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4875 11Standard Test Methods ofPolyurethane Raw Materials: Determination of thePolymerized Ethylene Oxide Content of Polyether Polyols1This standard is issued under the fixed designation D4875; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 Test Method AProton Nuclear Magnetic ResonanceSpectroscopy (1H NMR) measures pol
3、ymerized ethylene oxide(EO) in ethylene oxide-propylene oxide polyethers used inflexible urethane foams and nonfoams. It is suitable for diolsmade from the commonly used initiators and containing EOpercentages above five. For triols initiated with glycerin andtrimethylol propane, an uncorrected EO v
4、alue is obtained sinceboth initiators have protons that contribute to the EO measure-ment.1.2 Test Method BCarbon-13 Nuclear Magnetic Reso-nance Spectroscopy (13C NMR) measures the polymerized EOcontent of ethylene oxide-propylene oxide polyethers used inflexible urethane foams and nonfoams. It is s
5、uitable for diolsand triols made from the commonly used initiators andcontaining EO percentages above five.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concer
6、ns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 A
7、STM Standards:2D883 Terminology Relating to PlasticsE386 Practice for Data Presentation Relating to High-Resolution Nuclear Magnetic Resonance (NMR) Spectros-copyE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsTerminology i
8、n these test methods followsthe standard terminology defined in Terminology D883 andPractice E386.3.2 Definitions of Terms Specific to This Standard:3.2.1 heteric polyol, na polyether polyol in which ethyl-ene oxide and propylene oxide units are randomly arranged.3.2.2 initiator, na substance with w
9、hich ethylene oxide orpropylene oxide reacts to form a polyether polyol.3.2.2.1 DiscussionOne initiator unit is incorporated intoeach polymer or oligomer molecule.3.2.3 EO capped polyola polyol that contains a terminalblock of ethylene oxide units4. Summary of Test Methods4.1 Test Method AThe1H NMR
10、spectra of polyetherpolyols show two groups of resonance peaks corresponding tothe methyl protons of propylene oxide (PO) and to themethylene and methine protons of EO and PO. The EO peakarea is obtained by subtracting the area of the PO methyl peaksfrom the area of the methylene and methine peaks.
11、Initiatorsother than glycols of EO and PO give systematic errors (seeNote 2).NOTE 2The initiator error can be estimated by calculating thetheoretical contribution of initiator protons to the EO and PO peak areas.4.2 Test Method BThe13C NMR spectra of polyetherpolyols contain multiple resonances aris
12、ing from initiator, EO,PO, EO/PO, sequencing, and end-group distribution. EO con-tent can be determined relative to PO or relative to PO and triolinitiator. In the former, the area of the EO peaks is ratioed to thetotal area of PO methylene and methine carbons. In the latter,the area of the EO peaks
13、 is ratioed to the total area of POmethylene and methine carbons and two initiator carbons. Thistest method describes the determination of EO relative to POonly.1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and is the direct responsibility of Subcommittee D20.22 on
14、CellularMaterials - Plastics and Elastomers.Current edition approved April 1, 2011. Published April 2011. Originallyapproved in 1988. Last previous edition approved in 2005 as D4875 - 05. DOI:10.1520/D4875-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
15、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
16、PA 19428-2959, United States.5. Significance and Use5.1 Measurements of EO content correlate with polyolreactivity (as related to primary hydroxyl content), linearity offoam rise, and the hydrophilicity of the polyol and finalproduct.5.2 Statistical data suggest that the13C NMR test method isthe pre
17、ferred method for measuring low levels (less than 10 %)of polymerized EO in polyols.5.3 The1H and13C NMR test methods give different resultswhich are highly correlated. The equation of the linear regres-sion is:%EOproton5 1.031 %EOcarbon213! 1 0.883 (1)The standard deviation of the regression is 0.4
18、9 and themultiple R-square is 0.9990.TEST METHOD AHYDROGEN-1 NMR6. Equipment6.1 NMR Continuous Wave (CW) or Fourier Transform(FT) Spectrometer, with a1H resonance frequency of 60 MHzor higher.6.2 NMR Sample Tubes, having an outside diameter of atleast 5 mm.7. Reagents and Materials7.1 All reagents a
19、re to be ACS-certified or spectroscopicgrade unless otherwise specified.7.2 Trifluoroacetic Acid.7.3 Chloroform-d1, NMR-grade, containing tetramethylsi-lane as an internal standard.8. Standard8.1 This test method does not require standards. To evaluatethe test method, standards can be prepared from
20、commerciallyavailable poly(propylene oxide) and poly(ethylene oxide).9. Preparation of Sample9.1 Mix a few drops of polyol with deuterated chloroform toprepare 1 mL of an approximately 10 %3polyol solution. Adda drop of trifluoroacetic acid, mix well, and transfer to an NMRtube.10. Instrument Prepar
21、ation10.1 The instrument settings given here are for a VarianEM-390 CW spectrometer, a Varian XL-100 FT spectrometer,and a Bruker AC 300 FT spectrometer. Instrument preparationcan vary with the spectrometer. For a description of a particularspectrometer and suitable parameters, refer to the manufact
22、ur-ers operating manual.10.2 Typical Varian EM-390 console settings are as follows:Lock optional, TMSOffset 0Sweep width 5 ppmSweep time 2 minIntegration time 2 minRf Filter openRF power 0.05 mG10.3 Typical Varian XL-100 console settings are as follows:Lock chloroform-d-1Pulse angle 90Pulse delay 0S
23、pectral width 10 ppmAcquisition time 4 sData points 8KNumber of transients 12810.4 Typical Bruker 300 MHz console settings are asfollows:Lock chloroform-d-1Pulse angle 90Pulse delay 5 sSpectral width 10 ppmAcquisition time 5.3 sData points 32KNumber of transients 6411. NMR Analysis11.1 Place the NMR
24、 tube containing the polyol solution intothe spectrometer probe and optimize the field homogeneity. ForCW NMR, scan the spectrum from 5 to 0 ppm. Integrate thespectrum five times at a power level below that which causessaturation. See Figs. 1 and 2 for examples of polyol spectrawith high and low EO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD48752011STANDARDTESTMETHODSOFPOLYURETHANERAWMATERIALSDETERMINATIONOFTHEPOLYMERIZEDETHYLENEOXIDECONTENTOFPOLYETHERPOLYOLS

链接地址:http://www.mydoc123.com/p-518285.html