《ASTM D4659-2014 Standard Test Methods for Polyurethane Raw Materials Determination of Specific Gravity of Isocyanates《聚氨酯原料的标准试验方法 异氰酸酯比重的测定》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4659-2014 Standard Test Methods for Polyurethane Raw Materials Determination of Specific Gravity of Isocyanates《聚氨酯原料的标准试验方法 异氰酸酯比重的测定》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4659 14Standard Test Methods forPolyurethane Raw Materials: Determination of SpecificGravity of Isocyanates1This standard is issued under the fixed designation D4659; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods determine the specific gravity oftoluenediisocyanate and crude methylene-bis-(4-phenylis
3、ocyanate). These test methods also are applicable tomany other liquids. (See Note 1.)1.1.1 Test Method ASpecific gravity by pycnometer, forhigh-accuracy determination.1.1.2 Test Method BSpecific gravity by hydrometer, for aless accurate, but rapid, determination.1.2 The values stated in SI units are
4、 to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices
5、and determine the applica-bility of regulatory limitations prior to use. For specificwarning and precautionary statements see Section 7.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD891 Test Methods for Specif
6、ic Gravity,Apparent, of LiquidIndustrial ChemicalsD1193 Specification for Reagent WaterD4052 Test Method for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterE100 Specification for ASTM HydrometersE202 Test Methods for Analysis of Ethylene Glycols andPropylene GlycolsE225
7、1 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision Liquids3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods see Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 specific gravitythe ratio of the weight in air of agiv
8、en volume of the material at a stated temperature to theweight in air of an equal volume of water at a statedtemperature. It shall be expressed as specific gravity, 25/25C,indicating that the sample and reference water were bothmeasured at 25C.4. Significance and Use4.1 These test methods can be use
9、d for research or forquality control to characterize isocyanates used in polyurethaneproducts.4.2 Ageneral test method for specific gravity using a digitaldensity meter, which applies to isocyanates as well as otherliquids is published in Test Method D4052.TEST METHOD ASPECIFIC GRAVITY BYPYCNOMETER5
10、. Apparatus5.1 Pycnometer, of 25 or 50-mLcapacity, conical shape witha capillary side arm overflow tube having a standard-taper 5/12ground-glass joint and a ground-glass vented cap. A thermom-eter graduated from 12 to 38C in 0.2 divisions attached to theneck of the flask by a standard-taper 10/18 gr
11、ound-glass joint.This thermometer is to be calibrated using the ASTM ther-mometer specified in 5.3.5.2 Water BathA water bath maintained at 25 6 0.05C.5.3 ThermometerAn ASTM low-softening pointthermometer, calibrated from 2 to +80C, which meets therequirements for Thermometer S15C in Specification E
12、2251.5.4 Analytical BalanceAbalance having a sensitivity of atleast 0.1 mg.1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.22 on CellularMaterials - Plastics and Elastomers.Current edition approved March 1, 2014. P
13、ublished March 2014. Originallyapproved in 1987. Last previous edition approved in 2009 as D4659 - 09. DOI:10.1520/D4659-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, r
14、efer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Reagents and Materials6.1 Purity of ReagentsUse reagent
15、 grade chemicals in alltests. Unless otherwise indicated, it is intended that all reagentsconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society where suchspecifications are available.3Other grades can be used, pro-vided it is ascertained that the reage
16、nt is of sufficiently highpurity to permit its use without lessening the accuracy of thedetermination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type IV or better of Specification D1193.6.3 Chromic Acid Cleaning SolutionPr
17、epare a saturatedsolution of chromic acid (CrO3) in concentrated sulfuric acid(H2SO4, sp gr 1.84).7. Sampling7.1 Since organic isocyanates react with atmosphericmoisture, take special precautions in sampling. Usual samplingmethods, even when conducted rapidly, can cause contamina-tion of the sample
18、with insoluble urea. Therefore, blanket thesample with dry air or nitrogen at all times. (WarningManydiisocyanates are known or suspected sensitizers. Over-exposure to diisocyanates can lead to adverse health effects,which may include the development of occupational asthmaand other respiratory, skin
19、, and eye effects. Engineeringcontrols, or personal protective equipment, or both, includingrespiratory, skin, and eye protection, are to be used when thereis a potential for over-exposure to diisocyanates. The productsuppliers Material Safety Data Sheet (MSDS) provides moredetailed information abou
20、t potential adverse health effects andother important safety and handling information. Alwaysfollow the specific instructions provided on the MSDS.)8. Test Conditions8.1 Since isocyanates react with moisture, keep laboratoryhumidity low, preferably around 50 % relative humidity.9. Procedure9.1 Clean
21、 the pycnometer by filling it with chromic acidcleaning solution and by allowing it to stand for a few hours.Empty the pycnometer and rinse well with distilled water.9.2 Fill the pycnometer with freshly boiled distilled waterthat has been cooled to 22 to 24C. Insert the thermometer intothe pycnomete
22、r without trapping air bubbles. Place the pyc-nometer in a water bath at 25 6 0.05C and allow it and itscontents to equilibrate for at least 30 min. Wipe the overflowfrom the side-arm capillary and cover it with the vented cap.Remove the pycnometer from the bath, wipe dry, and weigh.9.3 Empty the py
23、cnometer and rinse it with alcohol, thenwith ether. Remove the ether and dry the pycnometer undervacuum for 15 min. Weigh the pycnometer. Determine theweight, W, of the water at 25.0C in air by subtracting theweight of the empty pycnometer from the weight of thepycnometer filled with water.NOTE 2Oth
24、er drying techniques can be used if ether is to be avoided.It must be established that for any alternative drying method, a clean anddry pycnometer results.9.4 Carry out the rest of the procedure in a ventilated hood.The sample for testing must be completely liquid. If the samplecontains solid tolue
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46592014STANDARDTESTMETHODSFORPOLYURETHANERAWMATERIALSDETERMINATIONOFSPECIFICGRAVITYOFISOCYANATES

链接地址:http://www.mydoc123.com/p-517632.html