《ASTM D4659-2003 Standard Test Methods for Polyurethane Raw Materials Determination of Specific Gravity of Isocyanates《聚氨基甲酸酯原材料的标准试验方法 异氰酸酯比重的测定》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4659-2003 Standard Test Methods for Polyurethane Raw Materials Determination of Specific Gravity of Isocyanates《聚氨基甲酸酯原材料的标准试验方法 异氰酸酯比重的测定》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4659 03Standard Test Methods forPolyurethane Raw Materials: Determination of SpecificGravity of Isocyanates1This standard is issued under the fixed designation D 4659; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods determine the specific gravity oftoluenediiosocyanate and crude methylene-bis-(4-phen
3、ylisocyanate). These test methods also are applicable tomany other liquids. (See Note 1.)1.1.1 Test Method ASpecific gravity by pycnometer, forhigh-accuracy determination.1.1.2 Test Method BSpecific gravity by hydrometer, for aless accurate, but rapid, determination.1.2 The values stated in SI units
4、 are to be regarded as thestandard. The values given in brackets are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practic
5、es and determine the applica-bility of regulatory limitations prior to use. For specificwarning and precautionary statements see Notes 2 and 3.NOTE 1There is no equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:2D 883 Terminology Relating to PlasticsD 891 Test Methods for Specific Gr
6、avity, Apparent, ofLiquid Industrial ChemicalsD 1193 Specification for Reagent WaterE 1 Specification for ASTM ThermometersE 100 Specification for ASTM HydrometersE 202 Test Methods for Analysis of Ethylene Glycols andPropylene Glycols3. Terminology3.1 Definitions:3.1.1 For definitions of terms used
7、 in these test methods seeTerminology D 883.3.2 Description of Term Specific to This Standard:3.2.1 specific gravitythe ratio of the weight in air of agiven volume of the material at a stated temperature to theweight in air of an equal volume of water at a statedtemperature. It shall be expressed as
8、 specific gravity, 25/25C,indicating that the sample and reference water were bothmeasured at 25C.4. Significance and Use4.1 These test methods can be used for research or forquality control to characterize isocyanates used in polyurethaneproducts.TEST METHOD ASPECIFIC GRAVITY BYPYCNOMETER5. Apparat
9、us5.1 Pycnometer, of 25 or 50-mL capacity, conical shape witha capillary side arm overflow tube having a standard-taper 5/12ground-glass joint and a ground-glass vented cap. A thermom-eter graduated from 12 to 38C in 0.2 divisions attached to theneck of the flask by a standard-taper 10/18 ground-gla
10、ss joint.This thermometer should be calibrated using the ASTMthermometer specified in 5.3.5.2 Water BathA water bath maintained at 25 6 0.05C.5.3 ThermometerAn ASTM low-softening point ther-mometer, calibrated from 2 to +80C, which meets therequirements for Thermometer 15C in Specification E 1.5.4 A
11、nalytical BalanceA balance having a sensitivity of atleast 0.1 mg.6. Reagents and Materials6.1 Purity of ReagentsUse reagent grade chemicals in alltests. Unless otherwise indicated, it is intended that all reagentsconform to the specifications of the Committee on Analytical1These test methods are un
12、der the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.22 on CellularPlastics.Current edition approved November 1, 2003. Published January 2004. Originallyapproved in 1987. Last previous edition approved in 1998 as D 4659 - 98.2For referenced ASTM
13、 standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM
14、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Reagents of the American Chemical Society where suchspecifications are available.3Other grades may be used, pro-vided it is ascertained that the reagent is of sufficiently highpurity to permit its use
15、 without lessening the accuracy of thedetermination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type IV or better of Specification D 1193.6.3 Chromic Acid Cleaning SolutionPrepare a saturatedsolution of chromic acid (CrO3)
16、in concentrated sulfuric acid(H2SO4, sp gr 1.84).7. Sampling7.1 Since organic isocyanates react with atmospheric mois-ture, take special precautions in sampling WarningOrganicisocyanates are toxic when they are absorbed through the skin,or when the vapors are breathed. PrecautionProvide ad-equate ve
17、ntilation and wear protective gloves and eyeglassesUsual sampling methods (for example, sampling an open drumwith a thief), even when carried out rapidly, can causecontamination of the sample with insoluble urea. Therefore,blanket the sample with dry air or nitrogen at all times.8. Test Conditions8.
18、1 Since isocyanates react with moisture, keep laboratoryhumidity low, preferably around 50 % relative humidity.9. Procedure9.1 Clean the pycnometer by filling it with chromic acidcleaning solution and by allowing it to stand for a few hours.Empty the pycnometer and rinse well with distilled water.9.
19、2 Fill the pycnometer with freshly boiled distilled waterthat has been cooled to 22 to 24C. Insert the thermometer intothe pycnometer without trapping air bubbles. Place the pyc-nometer in a water bath at 25 6 0.05C and allow it and itscontents to equilibrate for at least 30 min. Wipe the overflowfr
20、om the side-arm capillary and cover it with the vented cap.Remove the pycnometer from the bath, wipe dry, and weigh.9.3 Empty the pycnometer and rinse it with alcohol, thenwith ether. Remove the ether and dry the pycnometer undervacuum for 15 min. Weigh the pycnometer. Determine theweight, W, of the
21、 water at 25.0C in air by subtracting theweight of the empty pycnometer from the weight of thepycnometer filled with water.NOTE 2Other drying techniques may be used if ether is to be avoided.It must be established that for any alternative drying method, a clean anddry pycnometer results.9.4 Carry ou
22、t the rest of the procedure in a ventilated hood.The sample for testing must be completely liquid. If the samplecontains solid toluene diisocyanate, warm it in its originalcontainer until it becomes liquid. Rapidly cool the liquid to 22to 24C and fill the pycnometer, while minimizing exposure ofthe
23、sample to air.9.5 Insert the thermometer into the pycnometer withouttrapping air bubbles. Cover the side arm with the vented capand allow the pycnometer to equilibrate in the water bath for atleast 30 min. Wipe the overflow from the side arm capillaryand cover it with the cap vented. Remove the pycn
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46592003STANDARDTESTMETHODSFORPOLYURETHANERAWMATERIALSDETERMINATIONOFSPECIFICGRAVITYOFISOCYANATES

链接地址:http://www.mydoc123.com/p-517630.html