ASTM D4164-2013(2018) Standard Test Method for Mechanically Tapped Packing Density of Formed Catalyst and Catalyst Carriers.pdf
《ASTM D4164-2013(2018) Standard Test Method for Mechanically Tapped Packing Density of Formed Catalyst and Catalyst Carriers.pdf》由会员分享,可在线阅读,更多相关《ASTM D4164-2013(2018) Standard Test Method for Mechanically Tapped Packing Density of Formed Catalyst and Catalyst Carriers.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4164 13 (Reapproved 2018)Standard Test Method forMechanically Tapped Packing Density of Formed Catalystand Catalyst Carriers1This standard is issued under the fixed designation D4164; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the me-chanically tapped density of formed cat
3、alyst and catalystcarriers. For the purpose of this test method, catalyst particlesare defined as extrudates, spheres, or formed pellets of 0.8 to4.8-mm (132 to316-in.) nominal diameter.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is th
4、eresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accor-dance with internationally recognized principles on standa
5、rd-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D3766 Terminology Relating to Catalysts and Cat
6、alysisE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1272 Specification for Laboratory Glass Graduated Cylin-ders3. Terminolog
7、y3.1 DefinitionsSee Terminology D3766.4. Summary of Test Method4.1 A preconditioned sample of formed catalyst or catalystcarrier is tapped in a graduated cylinder. The mechanicallytapped packing density is determined from the known mass andtapped volume.5. Significance and Use5.1 This test method is
8、 to be used for measuring themechanically tapped packing density of formed particles thatwill not break up during sampling, filling, or tapping of themeasuring cylinder under test conditions.6. Apparatus6.1 Graduated Cylinder, capacity 250 mL, conforming toSpecification E1272, Class A, with a base d
9、esigned to accom-modate the cylinder holder.6.2 Cylinder Holder, weighing approximately 1 lb (454 g).6.3 Tapping Device, consisting of a base-plate with wormdrive, reduction ratio 15:1, nominal cam shaft speed of 250r/min, tapping stroke travel18 in. (3.2 mm).6.4 Four Digit Adjustable Counter, which
10、 can be preset todeliver any number of taps between 1 and 9999.6.5 Desiccator, with a desiccant grade molecular sieve suchas No. 4A.6.6 Balance having a sensitivity of 0.1 g.6.7 Drying Oven.7. Procedure7.1 Heat an adequate sample(s) at 400 6 15C for not lessthan 3 h. Normally, this treatment can tak
11、e place in air.However, in the case of materials that might react with air atelevated temperatures (such as prereduced catalysts) the heattreatment should take place in an inert atmosphere. Afterheating, cool the test sample(s) in a desiccator or other suitablecontainer to eliminate the possibility
12、of moisture adsorptionprior to testing.NOTE 1These conditions may not be appropriate for all materials.NOTE 2Since many catalyst formulations are strong adsorbents, theuse of No. 4A indicating (cobalt-treated) molecular sieves as a desiccatingmedium is suggested. The desiccant should be regenerated
13、at 493 K1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.02 on Physical-Mechanical Properties.Current edition approved May 1, 2018. Published May 2018. Originallyapproved in 1988. Last previous edition approved in 2013
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD416420132018STANDARDTESTMETHODFORMECHANICALLYTAPPEDPACKINGDENSITYOFFORMEDCATALYSTANDCATALYSTCARRIERSPDF

链接地址:http://www.mydoc123.com/p-516423.html