ASTM D3826-1998(2008) Standard Practice for Determining Degradation End Point in Degradable Polyethylene and Polypropylene Using a Tensile Test《用拉伸试验对聚乙烯和聚丙烯老化过程的最终老化点的测定的标准实施规程》.pdf
《ASTM D3826-1998(2008) Standard Practice for Determining Degradation End Point in Degradable Polyethylene and Polypropylene Using a Tensile Test《用拉伸试验对聚乙烯和聚丙烯老化过程的最终老化点的测定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3826-1998(2008) Standard Practice for Determining Degradation End Point in Degradable Polyethylene and Polypropylene Using a Tensile Test《用拉伸试验对聚乙烯和聚丙烯老化过程的最终老化点的测定的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3826 98 (Reapproved 2008)Standard Practice forDetermining Degradation End Point in DegradablePolyethylene and Polypropylene Using a Tensile Test1This standard is issued under the fixed designation D 3826; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the determination of a degradation-end point (a
3、brittle point) for degradable polyethylene/polypropylene films and sheeting less than 1.0 mm (0.04 in.)thick. This practice is not intended for determination of the rateof degree of degradation of a polyethylene/polypropylene filmor sheet, but rather, to assess when in the course of itsdegradation u
4、nder some condition, a brittle point is reached. Ifone wishes to monitor tensile elongation during the degrada-tion process (such as when the tensile elongation is signifi-cantly greater than 5 %), Test Method D 882 is recommended.This practice should not be considered the only way ofdetermining a d
5、egradation-end point.1.2 Tensile properties of plastics 1.0 mm (0.04 in.) orgreater in thickness shall be determined in accordance withTest Method D 638.1.3 Use a static weighing-constant rate of grip separationtest. This procedure employs a constant rate of separation ofthe grips holding the sample
6、 and a static load cell.NOTE 1This procedure is based on the use of grip separation as ameasure of extension; however, the desirability of using extensionindicators accurate to 61.0 % or better as specified in Test Method D 638is recognized, and a provision for the use of such instrumentation isinco
7、rporated in the procedure.1.4 This procedure has been successful for determining thedegradation end point of ethylene-carbon-monoxide copoly-mers and has screened successfully two other additive-typepolyethylenes in a round robin test.1.5 The values stated in SI units are to be regarded as thestanda
8、rd. The values in parentheses are for information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
9、 of regulatory limitations prior to use.1.7 There is no equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:2D 374 Test Methods for Thickness of Solid Electrical Insu-lationD 618 Practice for Conditioning Plastics for TestingD 638M Standard Test Method for Tensile Properties ofPlastics
10、 (Metric)3D 882 Test Method for Tensile Properties of Thin PlasticSheetingD 5208 Practice for Fluorescent Ultraviolet (UV) Exposureof Photodegradable PlasticsD 691 Discontinued 1981; Specification for CompoundPowdered Soap (Granulated, with Rosin)33. Terminology3.1 Definitions:3.1.1 Definitions of t
11、erms and symbols relating to tensiontesting of plastics appear in the Annex to Test Method D 638.3.1.2 line grips, nin tensile testing machines, grips havingfaces designed to concentrate the entire gripping force along asingle line perpendicular to the direction of testing stress.3.1.3 tear failure,
12、 nin tensile testing of films, a failurecharacterized by fracture initiating at one edge of the specimenand progressing across the specimen at a rate slow enough toproduce an anomalous load-deformation curve.3.2 Description of Terms Specific to This Standard:3.2.1 film, nfor the purpose of this prac
13、tice, a piece ofmaterial not exceeding 0.250 mm (0.01 in.) in thickness.3.2.2 brittle point, nin degradable polyethylene/polypropylene film, that point in the history of a material when75 % of the specimens tested have a tensile elongation at breakof 5 % or less.4. Significance and Use4.1 The tensil
14、e elongation property determined by thispractice is of value for the characterization of degradable1This practice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.96 on Environmentally DegradablePlastics and Biobased Products.Current edit
15、ion approved Aug. 1, 2008. Published September 2008. Originallyapproved in 1991. Last previous edition approved in 2002 as D 3826 98 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volum
16、e information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.materials. The tensile elongation property may vary withspecimen thickness, method of preparati
17、on, speed of testing,type of grips used, and manner of measuring test extension.Consequently, where precise comparative results are desired,these factors must be carefully controlled.4.2 The tensile elongation property may be utilized toprovide data for research and development and engineeringdesign
18、 as well as quality control specifications. However, datafrom such tests cannot be considered significant for applica-tions differing widely from the load-time scale of the testemployed.4.3 Materials that fail by tearing give anomalous data thatcannot be compared with those from normal failure.4.4 B
19、efore proceeding with this test method, referenceshould be made to the specifications of the material beingtested. Any test specimen preparation, conditioning, dimen-sions, or testing parameters or a combination thereof, coveredin the material specifications shall take precedence over thosementioned
20、 in this test method. If there are no materialspecifications, then the default conditions apply.5. Apparatus5.1 Testing Machines:5.1.1 Use a testing machine of the constant rate-of-jaw-separation type. The machine shall be equipped with a weigh-ing system that moves a maximum distance of 2 % of thes
21、pecimen extension within the range being measured. Also,there should be a device for recording the tensile load and theamount of separation of the grips; both of these measuringsystems shall be accurate to 62 %. The rate of separation ofthe grips shall be uniform and capable of adjustment fromapprox
22、imately 1.3 to 500 mm/min (0.05 to 20 in./min) inincrements necessary to produce the strain rates specified in9.2.5.2 GripsUse a gripping system that minimizes bothslippage and uneven stress distribution with the test specimen.NOTE 2Grips lined with thin rubber, crocus-cloth, or pressure-sensitive t
23、ape as well as file-faced or serrated grips have been successfullyused for many materials. The choice of grip surface depends on thematerial tested and thickness. More recently, line grips padded on theround face with 1.0 mm (40 mil) blotting paper have been found superior.Air-actuated grips have be
24、en found advantageous, particularly in the caseof materials that tend to neck into the grips, since pressure is maintainedat all times. In cases where samples frequently fail at the edge of the grips,it may be advantageous to increase slightly the radius of curvature of theedges where the grips come
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD382619982008STANDARDPRACTICEFORDETERMININGDEGRADATIONENDPOINTINDEGRADABLEPOLYETHYLENEANDPOLYPROPYLENEUSINGATENSILETEST

链接地址:http://www.mydoc123.com/p-515569.html