ASTM D3558-2003 Standard Test Methods for Cobalt in Water《水中钴含量的标准测试方法》.pdf
《ASTM D3558-2003 Standard Test Methods for Cobalt in Water《水中钴含量的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3558-2003 Standard Test Methods for Cobalt in Water《水中钴含量的标准测试方法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3558 03Standard Test Methods forCobalt in Water1This standard is issued under the fixed designation D 3558; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates
2、 the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover the determination of dissolvedand total recoverable cobalt
3、 in water and wastewater2byatomic absorption spectrophotometry. Three test methods areincluded as follows:Concentration Range SectionsTest Method AAtomic Absorption,Direct 0.1 to 10 mg/L 7 to 16Test Method BAtomic Absorption,Chelation-Extraction 10 to 1000 g/L 17 to 26Test Method CAtomic Absorption,
4、Graphite Furnace 5 to 100 g/L 27 to 361.2 Test Method A has been used successfully with reagentwater, potable water, river water, and wastewater. Test MethodB has been used successfully with reagent water, potable water,river water, sea water and brine. Test Method C was success-fully evaluated in r
5、eagent water, artificial seawater, river water,tap water, and a synthetic brine. It is the analysts responsibilityto ensure the validity of these test methods for other matrices.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespons
6、ibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 11.7.1, 21.10, and 23.10.2. Referenced Documents2.1 ASTM Standards:D 858 Test Methods for Manganese i
7、n Water3D 1066 Practice for Sampling Steam3D 1068 Test Methods for Iron in Water3D 1129 Terminology Relating to Water3D 1193 Specification for Reagent Water3D 1687 Test Methods for Chromium in Water3D 1688 Test Methods for Copper in Water3D 1691 Test Methods for Zinc in Water3D 1886 Test Methods for
8、 Nickel in Water3D 2777 Practice for Determination of Precision and Bias ofApplicable Methods of Committee D19 on Water3D 3370 Practices for Sampling Water from Closed Con-duits3D 3557 Test Methods for Cadmium in Water3D 3559 Test Methods for Lead in Water3D 3919 Practice for Measuring Trace Element
9、s in Water byGraphite Furnace Atomic Absorption Spectrophotometry3D 4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic Constituents3D 5810 Guide for Spiking into Aqueous Samples3D 5847 Practice for Writing Quality Control Specificationsfor Standard Test Me
10、thods for Water Analysis43. Terminology3.1 Definitions:3.1.1 For definitions of terms used in these test methods,refer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 total recoverable cobaltan arbitrary analytical termrelating to the recoverable forms of cobalt that a
11、re determin-able by the digestion method which is included in the proce-dure.4. Significance and Use4.1 Most waters rarely contain more than trace concentra-tions of cobalt from natural sources.Although trace amounts ofcobalt seem to be essential to the nutrition of some animals,large amounts have p
12、ronounced toxic effects on both plant andanimal life.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on Analytical1These test methods are under the jurisdictio
13、n of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Water.Current edition approved June 10, 2003. Published July 2003. Originallyapproved in 1977. Last previous edition approved in 1998 as D 3558 94 (1998).2Platte, J.A., and March, V.
14、M., “ANew Tool for the Water Chemist,” IndustrialWater Engineering, May 1965.3Annual Book of ASTM Standards, Vol 11.01.4Annual Book of ASTM Standards, Vol 11.02.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
15、onshohocken, PA 19428-2959, United States.Reagents of the American Chemical Society where suchspecifications are available.5Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.5.
16、2 Unless otherwise indicated, reference to water shall beunderstood to mean reagent water conforming to SpecificationD 1193, Type I. Other reagent water types may be used,provided it is first ascertained that the water is of sufficientlyhigh purity to permit its use without lessening the bias andpre
17、cision of the determination. Type II water specified at thetime of the round-robin testing of this test method.6. Sampling6.1 Collect the samples in accordance with PracticesD 3370 and Practice D 1066, as applicable.6.2 Preserve samples with HNO3(sp gr 1.42) to a pH of 2 orless immediately at the ti
18、me of collection, normally about 2mL/L. If only dissolved cobalt is to be determined, filter thesample through a 0.45-m membrane filter before acidification.The holding time for samples may be calculated in accordancewith Practice D 4841.TEST METHOD AATOMIC ABSORPTION, DIRECT7. Scope7.1 This test me
19、thod covers the determination of dissolvedand total recoverable cobalt in most waters and waste waters.It is the users responsibility to ensure the validity of this testmethod in a particular matrix.7.2 This test method is applicable in the range from 0.1 to10 mg/L of cobalt. The range may be extend
20、ed to concentra-tions greater than 10 mg/L by dilution of the sample.8. Summary of Test Method8.1 Cobalt is determined by atomic absorption spectropho-tometry. Dissolved cobalt is determined by aspirating a portionof the filtered sample directly with no pretreatment. Totalrecoverable cobalt is deter
21、mined by aspirating the samplefollowing hydrochloric-nitric acid digestion and filtration. Thesame digestion procedure may be used to determine totalrecoverable nickel (Test Methods D 1886), chromium (TestMethods D 1687), cadmium (Test Methods D 3557), copper(Test Methods D 1688), iron (Test Methods
22、 D 1068), lead (TestMethods D 3559), manganese (Test Methods D 858), zinc(Test Methods D 1691).9. Interferences9.1 Nitrate reportedly interferes at 1 mg/L by suppressingthe absorption of the cobalt. This interference can be elimi-nated by adding 18 000 mg/L of ammonium chloride toblanks, standards,
23、and samples.9.2 Other metals usually do not interfere in the determina-tion of cobalt by increasing or decreasing the amount ofabsorbed radiation. The most common interference is causedby a chemical reaction in the flame that prevents conversion ofthe cobalt to the atomic state.9.3 Sodium, potassium
24、, and sulfate, magnesium (4500 mg/L), iron (4000 mg/L), and nickel, lead, copper, zinc, cadmium,and chromium (10 mg/L each) do not interfere.9.4 Background correction or a chelation-extraction proce-dure (see Test Method B) may be necessary to determine lowlevels of cobalt in some water.NOTE 1Instru
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD35582003STANDARDTESTMETHODSFORCOBALTINWATER 水中 含量 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-514999.html