ASTM D3557-2017 Standard Test Methods for Cadmium in Water《水中镉含量的标准试验方法》.pdf
《ASTM D3557-2017 Standard Test Methods for Cadmium in Water《水中镉含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3557-2017 Standard Test Methods for Cadmium in Water《水中镉含量的标准试验方法》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3557 12D3557 17Standard Test Methods forCadmium in Water1This standard is issued under the fixed designation D3557; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses in
2、dicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the determination of dissolved and total recoverable cadmium in water and wastewater byatomic-absorption spectrophotometry and differ
3、ential pulse anodic stripping voltammetry.2 Section 44 on Quality Control pertainsto these test methods. Four test methods are included as follows:ConcentrationRange SectionsTest Method AAtomic Absorption,Direct0.05 to 2.0mg/L7 to 15Test Method BAtomic Absorption,Chelation-Extraction5 to 200 g/L 16
4、to 24Test Method CDifferential PulseAnodic Stripping Voltammetry1 to 100 g/L 25 to 34Test Method DAtomic Absorption,Graphite Furnace2 to 10 g/L 35 to 43ConcentrationRange SectionsTest Method AAtomic Absorption,Direct0.05 to 2.0mg/L7 to 15Test Method BAtomic Absorption,Chelation-Extraction5 to 200 g/
5、L 16 to 24Test Method CDifferential PulseAnodic Stripping Voltammetry1 to 100 g/L 25 to 34Test Method DAtomic Absorption,Graphite Furnace2 to 10 g/L 35 to 431.2 Test Method B can be used to determine cadmium in brines. It is the users responsibility to ensure the validity of these testmethods for wa
6、ters of untested matrices.1.3 ICP-MS or ICP-AES may also be appropriate but at a higher instrument cost. See Test Methods D5673 and D1976.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values statedgivenin each system are mathematical conv
7、ersions and may not be exact equivalents; therefore, each system shall be used independentlyof the other.parentheses are mathematical conversion to inch-pound units that are provided for information only and are notconsidered standard.1.5 This standard does not purport to address all of the safety c
8、oncerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.6 This international standard was developed in accordance with internationally r
9、ecognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D858 Test Methods f
10、or Manganese in Water1 These test methods are under the jurisdiction of ASTM Committee D19 on Water and are the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.Current edition approved Sept. 1, 2012June 1, 2017. Published September 2012June 2017. Originally approved in
11、 1977. Last previous edition approved in 20072012 asD3557 02 (2007)D35571. 12. DOI: 10.1520/D3557-12.10.1520/D3557-17.2 Platte, J. A., and Marcy, V. M., “A New Tool for the Water Chemist,” Industrial Water Engineering, May 1965.3 For referencedASTM standards, visit theASTM website, www.astm.org, or
12、contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have
13、 been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official docu
14、ment.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D1066 Practice for Sampling SteamD1068 Test Methods for Iron in WaterD1129 Terminology Relating to WaterD1193 Specif
15、ication for Reagent WaterD1687 Test Methods for Chromium in WaterD1688 Test Methods for Copper in WaterD1691 Test Methods for Zinc in WaterD1886 Test Methods for Nickel in WaterD1976 Test Method for Elements in Water by Inductively-Coupled Argon Plasma Atomic Emission SpectroscopyD2777 Practice for
16、Determination of Precision and Bias of Applicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD3558 Test Methods for Cobalt in WaterD3559 Test Methods for Lead in WaterD3919 Practice for Measuring Trace Elements in Water by Graphite Furnace Atomic Abs
17、orption SpectrophotometryD4841 Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic ConstituentsD5673 Test Method for Elements in Water by Inductively Coupled PlasmaMass SpectrometryD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality C
18、ontrol Specifications for Standard Test Methods for Water Analysis3. Terminology3.1 DefinitionsDefinitions: For definitions of terms used in these test methods, refer to Terminology D1129.3.1.1 For definitions of terms used in this standard, refer to Terminology D1129.3.2 Definitions of Terms Specif
19、ic to This Standard:3.2.1 continuing calibration blank, na solution containing no analytes (of interest) which is used to verify blank response andfreedom from carryover.3.2.2 continuing calibration verification, na solution (or set of solutions) of known concentration used to verify freedom fromexc
20、essive instrumental drift; the concentration is to cover the range of calibration curve.3.2.3 SCE, nsaturated calomel electrode.3.2.4 spiking solution, nthe standard solution added to the polarographic cell that is used to quantitate the sample.3.2.5 stripping peak potential, nthe applied potential
21、versus SCE at which the stripping peak current is a maximum.3.2.3 SCE, nsaturated calomel electrode.3.2.6 stripping peak signal, nthe current measured at the stripping peak maximum for a metal.3.2.7 total recoverable metal, na descriptive term relating to the metal forms of cadmium recovered in the
22、acid-digestionprocedure specified in these test standards.4. Significance and Use4.1 The test for cadmium is necessary because it is a toxicant and because there is a limit specified for cadmium in potable waterin the National Interim Primary Drinking Water Regulations. This test serves to determine
23、 whether the cadmium content of potablewater is above or below the acceptable limit.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conformto the specifications of the Committee on Analytical Reagents of
24、the American Chemical Society.4 Other grades may be used,provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the accuracy of thedetermination.5.2 Unless otherwise indicated, references to water shall be understood to mean reagent water
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD35572017STANDARDTESTMETHODSFORCADMIUMINWATER 水中 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-514998.html