《ASTM D3156-1996(2011) Standard Practice for RubberChromatographic Analysis of Antidegradants (Antioxidants Antiozonants and Stabilizers) 《橡胶标准操作规程 防降解剂(稳定剂 防氧化剂及防臭氧剂及稳定剂)的色谱分析》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3156-1996(2011) Standard Practice for RubberChromatographic Analysis of Antidegradants (Antioxidants Antiozonants and Stabilizers) 《橡胶标准操作规程 防降解剂(稳定剂 防氧化剂及防臭氧剂及稳定剂)的色谱分析》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3156 96 (Reapproved 2011)Standard Practice forRubberChromatographic Analysis of Antidegradants(Antioxidants, Antiozonants and Stabilizers)1This standard is issued under the fixed designation D3156; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the detection and identification bythin-layer chromatogr
3、aphy of antidegradants (antioxidants,antiozonants, and stabilizers) that may be present in raw rubberor rubber products. Analysis for other types of antidegradantsis possible as long as the requirements of the practice are met.1.2 The values stated in SI units are to be regarded as thestandard.1.3 T
4、his standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docume
5、nt2.1 ASTM Standards:2D297 Test Methods for Rubber ProductsChemicalAnaly-sis3. Summary of Practice3.1 A simplified procedure (Method A, Section 13.1) basedon a single-solvent system is presented, which provides for theidentification of known materials. This may be used to checkthe presence or absenc
6、e in a rubber vulcanizate or raw rubber,of an antidegradant which should be present. However, sincethe chromatograms obtained may not be absolutely specific forany given antidegradant, a more detailed scheme is given in13.2.3.2 Method B, Section 13.2, using additional solvents andsprays is included,
7、 which enables a greater degree of separationof the spots to be made and therefore may enable detection andidentification of an unknown antidegradant.3.3 Other techniques, for example: gas chromatographic(with or without treatment to obtain derivatives), spectroscopic(ultraviolet and infrared), more
8、 sophisticated thin-layer varia-tions (two dimensional techniques), may be applied to identi-fication of spots for improved detection and identification of anunknown antidegradant.3.4 It is possible that the chromatographic pattern of oneantidegradant may overlap that of another antidegradant;theref
9、ore each laboratory must prepare its own referencestandards, based on the technique chosen from this practice.4. Significance and Use4.1 This practice is useful for the examination of rubbercompounds or products for the presence of chemicals thatprevent or greatly reduce degradation due to oxygen, o
10、zone, orother agents.4.2 This practice is suitable for quality assurance, factorycontrol, and research and development applications.5. Interferences5.1 In the absence of extender oils, antidegradants areextracted from the rubber by a solvent and the evaporatedextract is applied directly to a thin-la
11、yer chromatographicplate.5.2 In the presence of extender oils, the oils are removed byeither a pre-treatment of the plate, with light petroleum ether orby a column chromatographic technique.5.3 Identification of the antidegradant is made by thestandard technique of thin-layer chromatography, herein
12、de-scribed.6. Apparatus6.1 Spreading Device, for making thin layer chromato-graphic plates with a coating 250 to 300 m thick.6.2 Glass Plates, 200 by 200-mm, or suitable for theselected tank. As an alternative to preparing plates, the use ofprecoated plates with a coating of 250 to 300 m is permitte
13、d.Precoated film-backed plates are not recommended.1This practice is under the jurisdiction of ASTM Committee D11 on Rubber andis the direct responsibility of Subcommittee D11.11 on Chemical Analysis.Current edition approved Nov. 1, 2011. Published January 2012. Originallyapproved in 1973. Last prev
14、ious edition approved in 2005 as D3156 96 (2005).DOI: 10.1520/D3156-96R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3 Drying Oven, 105C minimum.6.4 Desiccator, or drying box for storing plates at fixedhumidity.6.5 Micro-pipets, 5 and 10-mm3(L).6.6 Chromatographic Developing Tank, of a
16、size suitable tohold plates, approximately 250 by 250 by 70 mm to 330 by 240by 110 mm. Small “sandwich-type” tanks are not recom-mended. Add about 200 cm3of developing solvent (7.4)tothetank, swirl, cover, and allow to stand 15 min before using. Tankmay be reused by repeating the swirling and standi
17、ng step, aslong as the solvent ratio remains constant.6.7 Extraction Apparatus, in accordance with Section 18 or25 of Test Methods D297.6.8 Chromatographic Columns, short, liquid-solid. Thosefound satisfactory are as follows:6.8.1 Hypodermic Syringe Barrel, 5-cm3, fitted with aneedle about 35 mm in
18、length and 1.27 mm outside diameter(No. 18 BWG).6.8.2 Glass Tubes, 120 mm in length and 10 to 12 mm indiameter, holding about 5 cm3of silica gel.7. Reagents7.1 Plate AdsorbentSilica gel containing calcium sulfate.3Silica gel containing a fluorescent indicator may be useful insome cases to allow visu
19、alization of spots (before spraying)with ultraviolet light.7.2 Column AdsorbentSilica gel 200 to 600 m (30 to70-mesh),3activated by drying at 110C for at least 2 h, if dryin that period, or overnight (616 h) for convenience.7.3 SolventsUse of fume hoods with volatile and toxicsolvents is mandatory.
20、Approved health and safety precautionsshould be observed for the use of any solvent or chemicalmentioned in this procedure. ACS grade or equivalent shouldbe used.7.3.1 Methanol.7.3.2 Acetone.7.3.3 Isopropanol.7.3.4 Light Petroleum Ether.7.3.5 Chloroform.7.3.6 Toluene.7.3.7 Ethyl Acetate.7.3.8 n-Hexa
21、ne.7.3.9 n-Heptane.7.3.10 Cyclohexane.7.3.11 Diethylamine.7.3.12 Ammonium Hydroxide (NH4OH, 2830 % ammoniaNH3).7.3.13 WaterReferences to water shall be understood tomean distilled water or water of equal purity.7.4 Developing Solvents:7.4.1 Test Method A90 parts n-heptane and 10 parts ethylacetate b
22、y volume.7.4.2 Test Method B, used in the following order:7.4.2.1 Toluene.7.4.2.2 95 parts toluene and 5 parts ethyl acetate by volume.7.4.2.3 75 parts cyclohexane and 25 parts diethylamine byvolume.7.4.2.4 50 parts toluene and 50 parts n-heptane by volume.7.4.3 Additional developing solvents which
23、may proveuseful for special problems:7.4.3.1 100 parts toluene, 5 parts acetone and 0.1 partammonium hydroxide (NH4OH).7.4.3.2 100 parts toluene, 5 to 10 parts acetone and 0.1 to0.2 parts NH4OH.7.5 Spray Reagents for Color Development:7.5.1 Amines:7.5.1.1 Diazotized Sulfanilic Acid0.5 g of sulfanili
24、c acidand 0.5 g of potassium nitrite (KNO2) dissolved in 100 cm3of1 M hydrochloric acid (HCl). Make fresh daily.7.5.1.2 Benzoyl Peroxide (4 % solution in toluene).7.5.1.3 Tollens Reagent (0.5 cm3of 5 % silver nitrate(AgNO3) solution + 2 drops of 2 M sodium hydroxide (NaOH).Dissolve the precipitate i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD315619962011STANDARDPRACTICEFORRUBBERCHROMATOGRAPHICANALYSISOFANTIDEGRADANTSANTIOXIDANTSANTIOZONANTSANDSTABILIZERS

链接地址:http://www.mydoc123.com/p-514169.html