EN 60068-2-60-1996 en Environmental Testing - Part 2 Tests Test Ke Flowing Mixed Gas Corrosion Test (Remains Current)《环境试验 第2部分 试验 试验Ke 流动混合气体腐蚀试验(IEC 682-60-1995)》.pdf
《EN 60068-2-60-1996 en Environmental Testing - Part 2 Tests Test Ke Flowing Mixed Gas Corrosion Test (Remains Current)《环境试验 第2部分 试验 试验Ke 流动混合气体腐蚀试验(IEC 682-60-1995)》.pdf》由会员分享,可在线阅读,更多相关《EN 60068-2-60-1996 en Environmental Testing - Part 2 Tests Test Ke Flowing Mixed Gas Corrosion Test (Remains Current)《环境试验 第2部分 试验 试验Ke 流动混合气体腐蚀试验(IEC 682-60-1995)》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、CENELEC EN*hO*OhB- 2-60 96 W 3404583 0173033 05T BRITISH STANDARD Environmental testing Part 2. Tests Test Ke. Flowing mixed gas corrosion test The European Standard EN 6006Ek2-60 : 1996 has the status of a British Standard This part should be read in conjunction with BS EN 600681 : 1995 Geneml undg
2、uidance ICs 19.040 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYeowing mW gas m basic testing procedures and measuring methods - Part 2: General examination, electrical continuity and contact resistance tests, insulation tests and voltage stress rests IS0 431 : 1981 , Copper refinery
3、 shapes 2 lest apparatus The test apparatus consists of a climatic system, test enclosure, gas delivery system and means for measuring gas concentration. Details of design and construction are optional but shall be such that the conditions specified for each method are fulfilled throughout the worki
4、ng volume and shall comply with the following requirements: - water droplets or aerosols shall not be injected into the test enclosure; - air and water used shall be sufficiently clean in order not to affect performance of the test: COPYRIGHT European Committee for Electrotechnical StandardizationLi
5、censed by Information Handling ServicesCENELEC EN*bO*Ob8- 2-60 76 W 3Y04583 0173040 29T m Page 4 EN 60068-2-60 : 1996 - the test atmosphere shall flow through the enclosure in such a manner as to ensure uniform test conditions within the working volume; - the sampling point for gas analyses shall be
6、 in the working volume of the test enclosure; - the exhaust gases shall be treated in accordance with the relevant regulatory stipulations. The working volume is the volume within which the individual corrosion (weight increase of copper coupons expressed in mg / (dm2 x day) according to annex A) at
7、 each location differs by maximum 15 % from the average corrosion of all coupons within the working volume. 3 Severities The test severity shall be given in the relevant specification. It is defined by: - the test method, chosen from table 1, and - the test duration. Preferred durations are 4, 7, 10
8、, 14 and 21 days. Four methods are defined. The different parameters for each method are summarized in the following table l. A guidance for the use of each method is given in clause C.3. Table 1 Parameters HpS (1 O-0 vol/vol) NO vollvol) i/ B 3 8 CI (1 0-0 vol/vol) so (1 o- vol/vol) 1 Temperature “
9、C RH % Volume changes per hour Weight increase of copper coupons mg / (dm2 x day) according to annex A Method 1 100 f 20 500 100 25 f 1 75 f 3 3- 10 1 ,o - 2.0 Method 2 10t5 200 * 50 lof5 30 f 1 70 f 3 Method 3 100 i 20 200 i 50 20 f 5 30 f 1 75 f 3 3-10 I 3- 10 0.3 - 1.0 1,2 - 2,2 Method 4 lot 5 20
10、0 f 20 lof5 200 f 20 25 f 1 75 f 3 3- 10 1,2 - 2.4 71 mm3 /m3 2) NO,: 1 pg/m3 = 0,53 mm3 /m3 vol/vol) = UNIT (pg/m3) 3) CI,: 1 pg/m3 = 0,34 mm3 /m3 4) SO,: 1 pg/m3 = 038 mm3 /m3 NOTE - Since the nature of the corrosive attack is different for the test methods 1 to 4, neither their numbering nor the
11、corr,esponding weight increase of copper coupons reflect their severity. COPYRIGHT European Committee for Electrotechnical StandardizationLicensed by Information Handling ServicesCENELEC EN*bO*Ob8- 2-60 96 H 3404583 OL7304L L2b m Page 5 EN 60068-2-60 1996 4 Pre-conditionning The relevant specificati
12、on may require pre-conditioning of specimens, for example cleaning or mechanical operation. $ Initial measurements Initial measurements shall be carried out as required by the relevant specification. Generally these measurements are: - contact resistance measurements for electromechanical product co
13、mponents (IEC 512-2, test 2a); -. insulation resistance measurements (IEC 512-2, test 3a). 6 Testing Samples exposed in the tests shall be: - the specimens being evaluated; - corrosion monitor materials. 6.1 Test specimens The relevant product specification shall define the conditions of the specime
14、ns during the test, for example mated or unmated for connectors; contacts open or closed for switches, operated or electrically loaded. The duration of the operation or loading of heat-dissipating specimens, shall be such that the temperature and the relative humidity in the working volume remain wi
15、thin the specified tolerances. The conditions of the specimens and the test chamber shall be such that condensation on the specimens shall not occur when they are introduced into the test chamber. 6.2 Corrosivity monitoring materials Copper coupons shall be exposed with the test specimens in order t
16、o verify the conformance of the test specimen. A minimum of five test coupons of copper, prepared in accordance with annex A, shall be exposed with the test specimens for the same duration. Their increase in weight during the test, measured with appropriate sensitivity, shall be taken as a measure o
17、f the corrosion and as a monitor of the reproducibility and repeatibility of the test. Other vehicles, for example, gold-plated coupons or other specimens (see 8.6.3) can be used in addition to the copper coupons. COPYRIGHT European Committee for Electrotechnical StandardizationLicensed by Informati
18、on Handling ServicesCENELEC EN*bO*ObA- 2-60 7b W 3404583 0173042 Ob2 W Page 6 EN 60068-2-60 : 1996 6.3 Testing procedure One of the following test procedures shall be used: Test procedure 7 When the test atmosphere does not contain chlorine (method 1) or when the method for measuring chlorine concen
19、tration does not suffer interference from the other gases present in the test atmosphere, the following procedure shall be adopted: - start the flow of humid air, allow to stabilize and adjust temperature and humidity; - start the flow of the gases into the humid air stream and allow to stabilize: -
20、 measure and adjust gas concentrations. Allow to stabilize. When it is necessary to measure chlorine concentration, total chlorine (not only chlorine gas, CI,) present in the test atmosphere is taken as a measure of chlorine gas concentration. The chlorine added to the test atmosphere shall still on
21、ly be in the form of chlorine gas, CI,; - introduce the test specimens and the corrosion monitoring materials as prescribed in 6.2. The copper coupons shall be exposed with the test specimens for the full test period. The test specimens and the corrosion monitoring materials shall be distributed uni
22、formly in the working volume. They shall not come in contact with one another nor shield one another from the test atmosphere. The test specimens shall be in the condition (for example, matedhnmated, electrically loaded or operated) as stated in the relevant specification. The test duration shall be
23、 measured from this point; - allow the test conditions to stabilize, which may require considerable time. Measure and adjust, if necessary, temperature, humidity and gas concentrations. During these adjustments, any overshooting of gas concentration shall be avoided. Maximum allowed duration of this
24、 period of stabilization and adjustments, to prescribed values, is 24 h; - during the course of testing, temperature, humidity and gas concentrations shall be kept within the prescribed limits. The chamber is allowed to be opened during the test. The number of openings shall be limited. No opening i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN600682601996ENENVIRONMENTALTESTINGPART2TESTSTESTKEFLOWINGMIXEDGASCORROSIONTESTREMAINSCURRENT 环境 试验

链接地址:http://www.mydoc123.com/p-717497.html