1、Designation: D2851 98 (Reapproved 2015)D2851 15Standard Specification forLiquid Optical Adhesive1This standard is issued under the fixed designation D2851; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers liquid optical adhesive for use in bonding glass to glass or other transparent adherends.1.2 The values sta
3、ted in SI units are to be regarded as standard. The values given in parentheses are provided for informationpurposes only.1.3 The following precautionary caveat pertains only to the test method portion, Section 6, of this specification: This standarddoes not purport to address all of the safety conc
4、erns, if any, associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.Specific precautionary statements are given in 6.1.1.2. Referenced Documents2.1 ASTM
5、 Standards:2D542 Test Method for Index of Refraction of Transparent Organic PlasticsD897 Test Method for Tensile Properties of Adhesive BondsD904 Practice for Exposure of Adhesive Specimens to Artificial LightD907 Terminology of AdhesivesD1084 Test Methods for Viscosity of AdhesivesE308 Practice for
6、 Computing the Colors of Objects by Using the CIE SystemE1953 Practice for Description of Thermal Analysis and Rheology Apparatus3. Terminology3.1 DefinitionsMany terms in this specification are defined in Terminology D907.4. Significance and Use4.1 The bond strength tests provide reasonably accurat
7、e information with regard to the bond strength of the adhesives. Bondstrength data may be suitable for specification acceptance, service evaluation, manufacturing control, research, and development.Bond strength tests are not considered significant for applications differing widely from the test in
8、rate and type of loading.5. General Requirements5.1 The adhesive shall be in liquid form and free of solvent in order to avoid bubble formation in the adhesive layer. Eachcomponent shall be completely reactive (without residual volatile products). The adhesive may be heat-, catalyst-, orradiation-cu
9、red.5.1.1 VolatilityVolatile content of the adhesive shall not exceed 0.5 %, unless otherwise agreed upon between themanufacturer and the purchaser.5.1.2 ViscosityThe viscosity of the adhesive shall be within a well-defined range as agreed upon between the manufacturerand the purchaser.5.1.3 ColorTh
10、e color of the adhesive shall not exceed the color of a platinum-cobalt standard solution No. 300.1 This specification is under the jurisdiction of ASTM Committee D14 on Adhesives and is the direct responsibility of Subcommittee D14.60 on Adhesive MaterialClassification System.Current edition approv
11、ed April 1, 2015Sept. 1, 2015. Published April 2015September 2015. Originally approved in 1970. Last previous edition approved in 20092015 asD2851 98 (2009).(2015). DOI: 10.1520/D2851-98R15.10.1520/D2851-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer
12、Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the pre
13、vious version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM I
14、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.1.4 CleanlinessThe number and size of foreign particles found in 100 mL of the adhesive shall not exceed 5 particles in thesize range from 10 to 100 m (0.1 mm), and none larger than 100 m. The number
15、and size of foreign particles in the catalystrequired to cure 100 mL of the adhesive shall not exceed 2 particles in the size range from 10 to 100 m, and none larger than100 m.5.1.5 Refractive IndexThe refractive index of the cured adhesive shall be within a well-defined range as agreed upon between
16、the manufacturer and the purchaser.5.1.6 StabilityThe liquid adhesive shall not change in viscosity by greater than 20 % of its original viscosity nor show anyformation of solids, when tested as described in 6.6.5.1.7 Light TransmissionVisible light transmission through a bonded glass doublet (two g
17、lass disks bonded as described in6.8) shall not be less than 98.5 % of the total light transmitted through a single glass disk. There shall be no change in lighttransmission of a glass doublet after the environmental test (see 6.9).5.1.8 Environmental TestSeparation within the adhesive layer or from
18、 either glass surface of the glass doublet shall not exceed1.0 mm in depth nor extend beyond 180 of the periphery of the adhesive layer (see 6.9).5.1.9 Bond StrengthThe tensile strength of a bonded glass doublet after being subjected to the environmental test (see 6.9)shall be greater than 200 psi (
19、1.38 MPa) or any value agreed upon between the manufacturer and the purchaser.6. Test Methods6.1 Volatility:6.1.1 Thoroughly clean three petri dish bottoms, 95-mm outside diameter, by washing with detergent and a scrub brush. Rinsewith warm running tap water. Place petri dishes in an air-circulating
20、 oven for 30 min at 65 6 2C (150 6 4F). Raise temperatureto 110 6 2C (230 6 4F) for 1 h. Remove petri dishes from oven and place in a desiccator.After petri dishes have cooled to roomtemperature, approximately 2 h, weigh each dish to the nearest 0.1 mg. (WarningIn addition to other precautions, do n
21、ot handlepetri dishes with bare hands. Use tongs.)6.1.2 Replace each petri dish in the oven at 110 6 2C (230 6 4F) for 1 h. Repeat cool-down procedure. Reweigh each petridish to the nearest 0.1 mg. If weight agrees to within 60.2 mg of initial weight, proceed to 6.1.3. If weight exceeds this 60.2-mg
22、range, repeat process until a constant weight for each petri dish is obtained.6.1.3 To each petri dish add approximately 10 g of adhesive, and mix with catalyst or any component part required for curing.Weigh each dish to the nearest 0.1 mg. Cure the adhesive by following the procedure described by
23、the manufacturer. Then placeeach sample in an oven at 105 6 2C (220 6 4F) to a constant weight (same procedure as in 5.1.1 but at 105C). Reweigh eachsample to the nearest 0.1 mg and calculate the percent volatile matter as follows.Volatile matter,%5A 2B!/A# 3100 (1)where:A = weight of original sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD28512015STANDARDSPECIFICATIONFORLIQUIDOPTICALADHESIVE 液态 光学 胶粘剂 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-513637.html