ASTM D2593-1993(2009) Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography《用气相色谱法测定丁二烯纯度和烃类杂质的标准试验方法》.pdf
《ASTM D2593-1993(2009) Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography《用气相色谱法测定丁二烯纯度和烃类杂质的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2593-1993(2009) Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by Gas Chromatography《用气相色谱法测定丁二烯纯度和烃类杂质的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2593 93 (Reapproved 2009)Standard Test Method forButadiene Purity and Hydrocarbon Impurities by GasChromatography1This standard is issued under the fixed designation D2593; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of butadiene-1,3 purity and impurities such as propane, prop
3、ylene, isobu-tane, n-butane, butene-1, isobutylene, propadiene, trans-butene-2, cis-butene-2, butadiene-1,2, pentadiene-1,4, and,methyl, dimethyl, ethyl, and vinyl acetylene in polymerizationgrade butadiene by gas chromatography. Impurities includingbutadiene dimer, carbonyls, inhibitor, and residue
4、 are measuredby appropriate ASTM procedures and the results used tonormalize the component distribution obtained by chromatog-raphy.NOTE 1Other impurities present in commercial butadiene must becalibrated and analyzed. Other impurities were not tested in the coopera-tive work on this test method.NOT
5、E 2This test method can be used to check for pentadiene-1,4 andother C5s instead of Test Method D1088.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, i
6、f any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see 6.1 and 9.3.2. Referenced Documents2.1 ASTM Standard
7、s:2D1088 Method of Test for Boiling Point Range ofPolymerization-Grade Butadiene2.2 Energy Institute Standards:3IP 194 Analysis of Butadiene-1,3 Polymerization Grade3. Summary of Test Method3.1 A representative sample is introduced into a gas-liquidpartition column. The butadiene and other component
8、s areseparated as they are transported through the column by aninert carrier gas. Their presence in the effluent is measured bya detector and recorded as a chromatogram. The chromatogramof the sample is interpreted by applying component attenuationand detector response factors to the peak areas or p
9、eak heightsand the relative concentration determined by relating indi-vidual peak response to total peak response. Impurities includ-ing butadiene dimer, carbonyls, inhibitor, and residue aremeasured by appropriate ASTM procedures and the resultsused to normalize the distribution obtained by gas chr
10、omatog-raphy.4. Significance and Use4.1 The trace hydrocarbon compounds listed can have aneffect in the commercial use of butadiene. This test method issuitable for use in process quality control and in settingspecifications.5. Apparatus5.1 ChromatographAny chromatograph having either athermal-condu
11、ctivity or flame ionization detector can be usedprovided the system has sufficient sensitivity and stability toobtain a recorder deflection of at least 2 mm at signal-to-noiseratio of at least 5:1 for 0.01 weight % of impurity.5.2 ColumnAny column can be used that is capable ofresolving the componen
12、ts listed in 1.1 with the exception ofbutene-1 and isobutylene, which can be eluted together. Thecomponents should be resolved into distinct peaks such that theratio A/B will not be less than 0.5 where A is the depth of thevalley on either side of peak B and B is the height above thebaseline of the
13、smaller of any two adjacent peaks. In the casewhere the small component peak is adjacent to a large one, itcan be necessary to construct a baseline of the small peaktangent to the curve as shown in Fig. 1.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubr
14、icants and is the direct responsibility of SubcommitteeD02.D0.04 on C4 Hydrocarbons.This test method was adopted as a joint ASTM-IP Standard, IP 194, in 1972.Current edition approved July 1, 2009. Published November 2009. Originallyapproved in 1967. Last previous edition approved in 2004 as D259393(
15、2004)1.DOI: 10.1520/D2593-93R09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Obsolete. Contact Energy Ins
16、titute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.1 A description of columns that meet the requirementsof this test method is tabulated in the Appendix
17、. Persons usingother column materials must establish that the column givesresults that meet the precision requirements of Section 11.5.3 Sample Inlet SystemMeans shall be provided forintroducing a measured quantity of representative sample intothe column. Pressure-sampling devices can be used to inj
18、ect asmall amount of liquid directly into the carrier gas. Introduc-tion can also be accomplished by use of a gas valve to chargethe vaporized liquid.5.4 RecorderA recording potentiometer with a full-scaledeflection of 10 mV or less is suitable for obtaining thechromatographic data. Full-scale respo
19、nse time should be 2 sor less, and with sufficient sensitivity to meet the requirementsof 5.1.NOTE 3Other methods of recording detector output such as computer-teletype systems can be used instead of a recorder, provided precisionrequirements of Section 11 are met.6. Reagents and Materials6.1 Carrie
20、r GasA carrier gas appropriate to the type ofdetector used should be employed. Helium or hydrogen may beused with thermal conductivity detectors. Nitrogen, helium, orargon may be used with ionization detectors. The minimumpurity of any carrier should be 99.95 mol %. (WarningCompressed gas. Hazardous
21、 pressure.) (WarningHydrogenflammable gas. Hazardous pressure.)6.1.1 If hydrogen is used, special safety precautions must betaken to ensure that the system is free from leaks and that theeffluent is properly vented.6.2 Column Materials:6.2.1 Liquid PhaseThe materials that have been usedsuccessfully
22、in cooperative work as liquid phases are listed inTable X1.1.6.2.2 Solid SupportThe support for use in the packedcolumn is usually crushed firebrick or diatomaceous earth.Sieve size will depend on the diameter of the column used andliquid-phase loading, and should be such as would giveoptimum resolu
23、tion and analysis time. Optimum size rangescannot be predicted on purely theoretical grounds. For somesystems it has been found that a ratio of average particlediameter to column inside diameter of 1:25 will result inminimum retention time and minimum band widths.6.2.3 Tubing MaterialCopper, stainle
24、ss steel, Monel, alu-minum, and various plastic materials have been found to besatisfactory for column tubing. The material must be nonreac-tive with respect to substrate, sample, and carrier gas and ofuniform internal diameter.6.3 Hydrocarbons for Calibration and IdentificationHydrocarbon standards
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD259319932009STANDARDTESTMETHODFORBUTADIENEPURITYANDHYDROCARBONIMPURITIESBYGASCHROMATOGRAPHY 用气相

链接地址:http://www.mydoc123.com/p-513136.html