ASTM D2556-2011 Standard Test Method for Apparent Viscosity of Adhesives Having Shear-Rate-Dependent Flow Properties 《用切变速率决定其流动性能的胶粘剂的表观粘度的标准试验方法》.pdf
《ASTM D2556-2011 Standard Test Method for Apparent Viscosity of Adhesives Having Shear-Rate-Dependent Flow Properties 《用切变速率决定其流动性能的胶粘剂的表观粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2556-2011 Standard Test Method for Apparent Viscosity of Adhesives Having Shear-Rate-Dependent Flow Properties 《用切变速率决定其流动性能的胶粘剂的表观粘度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2556 11Standard Test Method forApparent Viscosity of Adhesives Having Shear-Rate-Dependent Flow Properties1This standard is issued under the fixed designation D2556; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the
3、measurement of the appar-ent viscosity of shear-rate-dependent adhesives.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
4、It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D907 Terminology of Adhesives3. Terminology3.1 Definitions: Many terms in this
5、 test method are definedin Terminology D907.3.1.1 Newtonian behavior, nthe property of a liquid inwhich its viscosity is constant over a stated range of strainrates. (Compare non-Newtonian behavior.)3.1.2 non-Newtonian behavior, nthe property of a liquidin which its viscosity is not constant over a
6、stated range ofstrain rates.3.2 Definitions of Terms Specific to This Standard:3.2.1 apparent viscosity, nresistance to shear at a givenrate of shear, expressed as viscosity in absolute units.4. Significance and Use4.1 The principle of measurement is based upon a reversibleisothermal change in appar
7、ent viscosity with change in rate ofshear.4.2 Measurement is performed with a spindle, disk, T-bar, orcoaxial cylinder rotational viscometer under standardized con-ditions with rigid control of the time intervals of measurement.Readings are obtained on the viscometer dial scale at the endof 1 min fo
8、r each rotational speed. Changes from the lowestspeed to the highest speed, and return to the lowest speed, aremade without stopping the instrument.5. Apparatus5.1 ViscometerThe apparatus consists of a spindle,3disk,3T-bar,3or coaxial-type viscometer with appropriate spindles,disks, T-bars, or cylin
9、ders. Do not use a scored, warped, orotherwise damaged spindle, disk, T-bar, or cylinder. Exceptwhen using the coaxial cylinder-type viscometer, the size ofcontainer to be used is determined by mutual agreement. Someinstruments have two concentric scales, and care is to be takento read the pointer o
10、n the correct scale.5.2 Supporting Stand4Use a support for the viscometerwhich consists of a suitable stand with a supporting armcapable of being lowered or raised either manually or mechani-cally.5.3 ThermometerUse a precision thermometer, withgraduations not greater than 0.2C (0.5F), for temperatu
11、remeasurements.6. Conditioning6.1 Condition the adhesive sample and instrument at 23 60.5C (73.4 6 1.0F) (or other temperature agreed upon1This test method is under the jurisdiction of ASTM Committee D14 onAdhesives and is the direct responsibility of Subcommittee D14.10 on WorkingProperties.Current
12、 edition approved Dec. 1, 2011. Published January 2012. Originallyapproved in 1966. Last previous edition approved in 2005 as D2556 93a (2005).DOI: 10.1520/D2556-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
13、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The Brookfield Synchro-Lectric, Dial Reading or Digital Viscometers (orRheometers), Ranges Models LV, RV, HA or HB have been found satisfactory forthis purpose and are available from the Brookfie
14、ld Engineering Laboratories,Middleboro, MA.4The Brookfield Helipath Stand or other commercially available stands may beused.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.between the adhesive vendor and the purchaser) at least 16 h.
15、If special conditioning methods are necessary, such as the useof a circulating water bath, they shall be noted in the report, see8.1.4.7. Procedure7.1 Select a viscometer and spindle (see Table X1.1), disk,T-bar, or cylinder suited to the viscosity range of the materialsuch that the model-speed-rota
16、tional element combination willgive dial readings between 20 and 80 % of the full-scalereading. Firmly fit the rotational element into the shaft exten-sion which goes down through the center of the dial casing.Place the viscometer on the supporting stand so that therotational element is vertical. Sl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD25562011STANDARDTESTMETHODFORAPPARENTVISCOSITYOFADHESIVESHAVINGSHEARRATEDEPENDENTFLOWPROPERTIES

链接地址:http://www.mydoc123.com/p-513068.html