ASTM D483-2004(2014) Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf
《ASTM D483-2004(2014) Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D483-2004(2014) Standard Test Method for Unsulfonated Residue of Petroleum Plant Spray Oils《石油制植物喷洒油不磺化残渣的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D483 04 (Reapproved 2014)Standard Test Method forUnsulfonated Residue of Petroleum Plant Spray Oils1This standard is issued under the fixed designation D483; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of unsul-fonated residue in plant spray oils of petroleum origin andapplies
3、only to the petroleum oil content. It provides a measureof the degree of refinement of plant spray oils by determiningthe extent to which the oil is attacked by 98.61 % sulfuric acidunder closely standardized conditions. Since the relationshipbetween unsulfonated residue and the actual composition o
4、f theoil is not known, this test method should be applied only formeasuring the degree of refinement and not for the determina-tion of aromatics or olefins, or both.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This st
5、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1
6、 ASTM Standards:2D1193 Specification for Reagent WaterD1250 Guide for Use of the Petroleum Measurement TablesD1298 Test Method for Density, Relative Density, or APIGravity of Crude Petroleum and Liquid Petroleum Prod-ucts by Hydrometer MethodD4052 Test Method for Density, Relative Density, and APIGr
7、avity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum Products3. Terminology3.1 Definitions:3.1.1 unsulfonated residue, n in oils, that portion of an oilremaining unsulfonated afte
8、r treatment with concentrated sul-furic acid.4. Summary of Test Method4.1 A measured volume of sample is shaken with 98.61 %sulfuric acid at 100C in a Babcock bottle, shaking mechani-cally for 10 s at 10-min intervals. The volume not absorbed bythe acid is a measure of the unsulfonated residue in th
9、e sample.5. Significance and Use5.1 This test method is useful for distinguishing betweenoils that are adaptable to various types of spraying application,with a higher unsulfonated oil being required for leaf sprayingas compared to dormant vegetation application.6. Apparatus6.1 Sulfonation FlaskThe
10、flask is shown in Fig. A1.1 anddescribed in Annex A1.6.2 Meniscus Viewing Lens, focusing type, consisting ofeyepiece and objective to facilitate reading the meniscus witha minimum of parallax, is recommended.6.3 Water Baths Two water baths maintained at 25 60.5C and 99.5 to 100C, and conforming to t
11、he requirementsprescribed in Annex A1.6.4 Shaking Machine The exact design described in theappendix is required for uniform control of shaking andprecision results. Hand shaking is permissible if technique isdeveloped to correlate results by machine shaking.6.5 CentrifugeA centrifuge as described in
12、 Annex A1 isrecommended.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,1This test method is u
13、nder the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.06 on Analysis of Lubricants.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 1961. Last previous edition approved in 2009
14、 as D483 04 (2009)01. DOI:10.1520/D0483-04R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM
15、International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the
16、determination.7.1.1 Commercially prepared solutions may be used whenthey meet or exceed the specifications set in 7.1.7.2 Fuming Sulfuric Acid (approximately 15 % free SO3).(WarningSee 7.3 and7.4.)7.3 Sulfuric Acid (98.61 %)Prepare by blending reagent-grade fuming and concentrated sulfuric acids to
17、a concentrationof 98.61 6 0.1 % H2SO4as determined by titration.(WarningCorrosive. Health hazard. Oxidizer.) (WarningWhile preparing the reagent, protect the face with a safetymask and place the flask in a tray.)7.4 Sulfuric Acid (sp gr 1.84, approximately 95 %)Concentrated sulfuric acid (H2SO4). (W
18、arningCorrosive.Health hazard. Oxidizer.).8. Reference Spray Oil48.1 Test results for unsulfonated residue are highly depen-dent upon rate of shaking. A reference spray oil has beencalibrated for unsulfonated residue by a group of cooperatinglaboratories using both machine and hand shaking. Instruct
19、ionsare given in Section 8 for using this reference oil as a guide toensure that the rate of shaking is correct.9. Calibration9.1 Machine Shaking RateA rate of 425 cycles/min wasused in the cooperative work to establish the unsulfonatedresidue of the reference spray oil. There are small variations i
20、nseverity of shaking between individual machines, even whenthey are newly built and of the same make; and thesedifferences can increase with use. Consequently, each labora-tory shall run occasional tests on the reference spray oil. If anunsulfonated residue is found which differs by more than60.4 %
21、from the established value, the rate of shaking shall beadjusted accordingly. A faster rate tends to give a lowerunsulfonated residue, and vice versa.9.2 Hand Shaking RateEach operator shall standardize histechnique of shaking so as to obtain the established value(within 6 0.4 %) on the reference sp
22、ray oil. A rate of300 cycles min was used in the manual shaking tests in thecooperative program on the reference oil; however, an indi-vidual operators calibrated rate can differ appreciably from300 cycles/min.10. Sampling10.1 Obtain a sample for this test method using PracticesD4057 or D4177.11. Pr
23、ocedure11.1 Adjust the temperature of the boiling water bath to 99.5to 100C and keep it in this temperature range throughout thetest. Adjust the shaker rate and check it before and after eachtest to make sure that the rate does not deviate more than610 cycles min from the rate established by calibra
24、tion.(WarningWhen hand shaking, protect the face with a safetymask and point the Babcock bottle away from other personnel.Protect hands by wearing suitable safety gloves.)NOTE 1If hand shaking is used, shake the sulfonation flask bygrasping the neck between the thumb and index finger and swinging th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD48320042014STANDARDTESTMETHODFORUNSULFONATEDRESIDUEOFPETROLEUMPLANTSPRAYOILS 石油 植物 喷洒 磺化 残渣 标准 试验

链接地址:http://www.mydoc123.com/p-511788.html