ASTM D2170-2007 Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens)《沥青的动粘度的标准试验方法》.pdf
《ASTM D2170-2007 Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens)《沥青的动粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2170-2007 Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens)《沥青的动粘度的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2170 07Designation: 319/84 (89)Standard Test Method forKinematic Viscosity of Asphalts (Bitumens)1This standard is issued under the fixed designation D 2170; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers procedures
3、 for the determina-tion of kinematic viscosity of liquid asphalts (bitumens), roadoils and distillation residues of liquid asphalts (bitumens) all at60C (140F) and of asphalt cements at 135C (275F) (Note1) in the range from 6 to 100 000 mm2/s (cSt).1.2 Results of this test method can be used to calc
4、ulateviscosity when the density of the test material at the testtemperature is known or can be determined. See Annex A1 forthe method of calculation.NOTE 1This test method is suitable for use at other temperatures andat lower kinematic viscosities, but the precision is based on determinationson liqu
5、id asphalts and road oils at 60C (140F) and on asphalt cementsat 135C (275F) only in the viscosity range from 30 to 6000 mm2/s (cSt).1.3 WarningMercury has been designated by UnitedStates Environmental ProtectionAgency (EPA) and many stateagencies as a hazardous material that can cause central nervo
6、ussystem, kidney and liver damage. Mercury, or its vapor, may behazardous to health and corrosive to materials. Caution shouldbe taken when handling mercury and mercury containingproducts. See the applicable product Material Safety DataSheet (MSDS) for details and EPAs websitehttp:/www.epa.gov/mercu
7、ry/faq.htmfor additional information.Users should be aware that selling mercury, mercury contain-ing products, or both, in your state may be prohibited by statelaw.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
8、 user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsD92 Tes
9、t Method for Flash and Fire Points by ClevelandOpen Cup TesterD 341 Test Method for Viscosity-Temperature Charts forLiquid Petroleum ProductsD 445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and Calculation of Dynamic Viscos-ity)D 446 Specifications and Operating Instructio
10、ns for GlassCapillary Kinematic ViscometersD 2162 Practice for Basic Calibration of Master Viscom-eters and Viscosity Oil StandardsD 2493 Standard Viscosity-Temperature Chart for AsphaltsE1 Specification for ASTM Liquid-in-Glass ThermometersE77 Test Method for Inspection and Verification of Ther-mom
11、eters3. Terminology3.1 Definitions:3.1.1 densitythe mass per unit volume of liquid and thecgs unit of density is 1 g/cm3. The SI unit of density is 1 kg/m3.3.1.2 kinematic viscositythe ratio of the viscosity to thedensity of a liquid. It is a measure of the resistance to flow ofa liquid under gravit
12、y. The SI unit of kinematic viscosity ism2/s; for practical use, a submultiple (mm2/s) is more conve-nient. The cgs unit of kinematic viscosity is 1 cm2/s and iscalled a stoke (symbol St). The centistoke (1 cSt = 102St) is1mm2/s and is often used.3.1.3 Newtonian liquida liquid in which the rate of s
13、hearis proportional to the shearing stress. The constant ratio of the1This test method is under the jurisdiction of ASTM Committee D04 on Roadand Paving Materials and is the direct responsibility of Subcommittee D04.44 onRheological Tests. In the IP this test method is under the jurisdiction of theS
14、tandardization Committee.Current edition approved Dec. 1, 2007. Published December 2007. Originallyapproved in 1963. Last previous edition approved in 2006 as D 2170 01a (2006).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
15、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.shearing stress to the rate of shear is the viscosity of the liquid.I
16、f the ratio is not constant, the liquid is non-Newtonian.3.1.4 viscositythe ratio between the applied shear stressand rate of shear is called the coefficient of viscosity. Thiscoefficient is a measure of the resistance to flow of a liquid. Itis commonly called the viscosity of the liquid. The cgs un
17、it ofviscosity is 1 g/cms (1 dynes/cm2) and is called a poise (P).The SI unit of viscosity is 1 Pas (1 Ns/m2) and is equivalentto 10 P.4. Summary of Test Method4.1 The time is measured for a fixed volume of the liquid toflow through the capillary of a calibrated glass capillaryviscometer under an ac
18、curately reproducible head and at aclosely controlled temperature. The kinematic viscosity is thencalculated by multiplying the efflux time in seconds by theviscometer calibration factor.5. Significance and Use5.1 The kinematic viscosity characterizes flow behavior.The method is used to determine th
19、e consistency of bitumen asone element in establishing the uniformity of shipments orsources of supply. The specifications are usually at tempera-tures of 60 and 135C.6. Apparatus6.1 Viscometers, capillary-type, made of borosilicate glass,annealed, suitable for this test are described in Annex A2 an
20、dinclude the following:6.1.1 Cannon-Fenske viscometer for opaque liquids,6.1.2 Zeitfuchs cross-arm viscometer,6.1.3 Lantz-Zeitfuchs viscometer,6.1.4 BS U-Tube modified reverse flow viscometer.6.1.5 Calibrated viscometers are available from commercialsuppliers. Details regarding calibration of viscom
21、eters aregiven in Annex A3.6.2 ThermometersCalibrated liquid-in-glass thermom-eters of an accuracy after correction of 0.02C (0.04F) can beused or any other thermometric device of equal accuracy.ASTM Kinematic Viscosity Thermometers 47C and 47F con-forming to Specification E1, and IP 35C and 35F are
22、 suitablefor use at 60C (140F) and ASTM Kinematic ViscosityThermometers 110C and 110F are suitable for use at 135C(275F).6.2.1 The specified thermometers are standardized at “totalimmersion,” which means immersion to the top of the mercurycolumn with the remainder of the stem and the expansionchambe
23、r at the top of the thermometer exposed to roomtemperature. The practice of completely submerging the ther-mometer is not recommended. When thermometers are com-pletely submerged, corrections for each individual thermom-eter based on calibration under conditions of completesubmergence must be determ
24、ined and applied. If the thermom-eter is completely submerged in the bath during use, thepressure of the gas in the expansion chamber will be higher orlower than during standardization, and may cause high or lowreadings on the thermometer. Thermometric devices for thistest method must be standardize
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD21702007STANDARDTESTMETHODFORKINEMATICVISCOSITYOFASPHALTSBITUMENS 沥青 粘度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511138.html