ASTM D2014-1997(2010) Standard Test Method for Expansion or Contraction of Coal by the Sole-Heated Oven《用底部加热炉对煤的膨胀性和收缩性测试的标准试验方法》.pdf
《ASTM D2014-1997(2010) Standard Test Method for Expansion or Contraction of Coal by the Sole-Heated Oven《用底部加热炉对煤的膨胀性和收缩性测试的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2014-1997(2010) Standard Test Method for Expansion or Contraction of Coal by the Sole-Heated Oven《用底部加热炉对煤的膨胀性和收缩性测试的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2014 97 (Reapproved 2010)Standard Test Method forExpansion or Contraction of Coal by the Sole-Heated Oven1This standard is issued under the fixed designation D2014; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a large-scale laboratory test forobtaining information on the expansion or contraction
3、 of coalor coal blends during carbonization under specified conditions.This test method is applicable in the examination of coals orcoal blends intended for use in the manufacture of coke.1.2 The values stated in SI units shall be regarded asstandard. Inch-pound units shall be accepted on an equival
4、entbasis.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Ref
5、erenced Documents2.1 ASTM Standards:2D2013 Practice for Preparing Coal Samples for AnalysisD2234/D2234M Practice for Collection of a Gross Sampleof CoalD3302 Test Method for Total Moisture in CoalE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Summary of Test Method3.1 During the
6、test, a measured thickness of coal about 102mm (4 in.) is heated from the bottom surface while a forcecorresponding to 15.2 kPa (2.20 psi) is applied to the topsurface through a piston. At the end of the test, the thickness ofthe coke is measured by observing the final position of thepiston.4. Signi
7、ficance and Use4.1 The values determined in this test method indicate towhat extent a given coal or coal blend will expand or contractduring the carbonization process when evaluated in terms ofpertinent experience with other coals and coal blends andprocessing conditions used in commercial-type coke
8、 ovens.5. Apparatus5.1 Test Oven Assembly, consisting of the following: eithera single-chamber oven having approximately 280-mm (11-in.)width, 610-mm (24-in.) length, and 280-mm depth, or adouble-chambered oven with two chambers each having ap-proximately 280-mm width, length, and depth; a heatingsy
9、stem to heat the charge(s) unidirectionally through the soleaccording to a controlled program; piston(s) arranged so that aconstant load may be applied to the top surface of the charge;and suitable instrumentation so that appropriate temperaturesand the position of the piston(s) may be measured. The
10、auxiliary equipment includes apparatus facilitating the charg-ing of the oven in a standard manner. The vertical partition ofthe double-chambered oven may be of 2-in. (51-mm) firebricktile or equivalent.5.1.1 Carbonization Chamber:5.1.1.1 The sole shall be of silicon carbide tile, about 40 mm(1.5 in
11、.) thick, 305 mm (12 in.) wide, and extending approxi-mately 75 mm (3 in.) beyond the carbonization chamber at thefront and back. Side, front, and back walls should be 40-mmfirebrick tile or equivalent. It is appropriate to key the sole tothe side and back tiles. The top edges of sidewalls shall be
12、heldin an adjustable steel framework so that the walls may be madeand maintained precisely perpendicular to the sole. Hole(s)6.35 mm (0.25 in.) in diameter shall be provided through theside of the oven to enable the placement of thermocouple(s) onthe top surface of the sole in the center of the oven
13、 chamber(s).5.1.1.2 In constructing the oven, the sides and ends of thecarbonization chamber shall be surrounded with at least 200mm (8 in.) of insulating refractories and the whole assemblyencased in a suitable restraining structure of steel shapes andplates designed to provide dimensional stabilit
14、y.5.1.2 Sole-Heating System:5.1.2.1 The heating system shall consist of a group ofelectrical heating elements mounted under the silicon carbidesole and suitable equipment to provide automatic control.Heating elements may be either silicon carbide-type resistanceelements or coils of heating wire encl
15、osed in silica tubes.Elements shall be arranged to obtain minimum variation oftemperature over the area of the sole. It is desirable to1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Coke and is the direct responsibility of Subcommittee D05.15 on MetallurgicalProperties
16、of Coal and Coke.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1962. Last previous edition approved in 2004 as D2014 97 (2004).DOI: 10.1520/D2014-97R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceas
17、tm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.incorporate a maximum number of supports for the siliconcarb
18、ide sole tile. The brickwork and steelwork beneath theheating flues shall be of appropriate design to maintain rigidityof the oven under the temperature and load stresses ofoperation.5.1.2.2 The thermocouple used for temperature control islocated in a position which enables the sole to be heated ina
19、ccordance with the sole temperature program shown in Table1. The heating system shall be capable of reachieving the initialset point temperature of 554C within 10 min of charging theoven and of heating the sole in accordance with the soletemperature program shown in Table 1.5.1.2.3 The temperature c
20、ontrol thermocouple may be in-stalled in the heating flue or in contact with the sole plate.5.1.3 PistonThe piston assembly shall include a massivebottom plate of metal to which an upper steel assembly isrigidly attached. The bottom plate shall be 19- or 25-mm (0.75-or 1-in.) cast steel or cast iron
21、 in one piece with square edges.Dimensions are to be so chosen that the clearances betweenpiston edges and chamber walls, ends, and sides, at theconclusion of a test (upper surface of coal at 500C) are at least3.2 mm (0.125 in.) but not as much as 9.5 mm (0.375 in.).A10-to 130-mm (4.5- to 5-in.) lay
22、er of insulating refractory shall beformed upon the steel plate, the sides being recessed somewhatwithin the piston edges. The upper steel assembly shall berigidly fastened to the corners of the lower plate with steelsupports. The upper steel assembly and corner supports shallbe of adequate strength
23、 to permit application of the desiredload and shall be fitted with appropriate hardware to permitready placement into or removal from the carbonizationchamber. A vertical hole, 13 mm (0.5 in.) in diameter, piercingthe piston assembly, including lower plate shall be provided onthe longitudinal center
24、 line for a thermocouple, about 200 mm(8 in.) from either the front or rear edge of the piston.5.1.4 Apparatus for Loading PistonApparatus shall beprovided so that a constant load of 15.17 6 0.35 kPa (2.20 60.05 psi) calculated over the measured area of the piston plate,may be applied to the piston
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD201419972010STANDARDTESTMETHODFOREXPANSIONORCONTRACTIONOFCOALBYTHESOLEHEATEDOVEN 底部 加热炉 膨胀 收缩 测试

链接地址:http://www.mydoc123.com/p-510847.html